Full Product Manual

10
33.75°
5 degrees of adjustment to accommodate
an unlevel beam.
33.75 degrees of adjustment to
accommodate 8/12 roof pitch.
Tighten all eight
locking nuts to 65
ft lbs with 3/4 inch
socket and torque
wrench.
RIGID MOUNT OVERVIEW
INSTALLATION
MOUNTING
1
Caution do not install the fan from a single structure such as a perlin, truss, i-beam, or bar joist.
For any questions or concerns regarding the building structure, consult a structural engineer.
Ensure the attachment point can support double two time the weight of the fan and maximum torque of 75ft
lbs. A structural engineer should verify the structure prior to fan installation.
To prevent SERIOUS INJURY or DEATH ALWAYS mount fan directly from building structure that can withstand
double the installed fan weight.
CRUSH HAZARD