Full Product Manual

11
INSTALLATION
MOUNTING
1
A
CHANNEL HEIGHT
MATERIAL THICKNESS
MAXIMUM SPAN LENGTH
1 5/8"
12 GA.
84"
1 5/8"
14 GA.
72"
1 5/8"
16 GA.
60"
1 3/8"
12 GA.
60"
7/8"
12 GA.
30"
3 1/4"
12 GA.
240"
2 7/16"
12 GA.
156"
Caution do not install the fan from a single structure such as a perlin, truss, I-beam, or bar joist.
For any questions or concerns regarding the building structure, consult a structural engineer.
Ensure the attachment point can support double two time the weight of the fan and maximum torque of 75ft lbs.
A structural engineer should verify the structure prior to fan installation.
To prevent SERIOUS INJURY or DEATH ALWAYS mount fan directly from building structure
that can withstand double the installed fan weight.
CRUSH HAZARD
Warning: Support directly from building structure
B
MULTI-POINT
ATTACHEMENT
TO BUILDING