Full Product Manual

INSTALLATION
RETENTION SYSTEM
2
A
B
Secure rst clamp on the loose
end of the cable.
Secure the remaining clamp in
the center of the two installed
clamps.
Secure the second clamp to the
cable approximately 6” from the
rst clamp.
B
Secure remaining cable
to itself with cable
clamps.
A
Wrap retention cable
around building structure
that can withstand
double the installed fan
weight.
13
When attaching cable clamps, remember to “Never saddle a dead horse”.
Place the u-bolt on the “dead” end of the Retention Cable and the saddle on the “live” portion of the
Retention Cable. The u-bolt will crush the wire when tightened and can reduce the strength of the wire.
NOTE
Make sure the retension
cable extends beyond the
end of the downrod.
CRUSH HAZARD. To prevent serious injury or death, ALWAYS attach
the Retention Cable to the fan motor and secure to the building
structure on EVERY fan.
Dead End
Live End