www.HunterFan.com Table of Contents Tools Needed Mounting Options Ceiling Bracket 30 inches Downrod To register your fan, please visit: www.HunterFan.com/register 4 Wiring Canopy Troubleshooting ? ? ? 15 PA G E 1 M0014-01 • 02/08/16 • © 2012–2016 Hunter Fan Company PA G E 14 PA G E 12 PA G E Maintenance & Cleaning Light Kit 5 11 Blades 10 PA G E 9 PA G E 6 Save your receipt for proof of purchase.
www.HunterFan.com What to Expect with Your Installation Read and Save These Instructions If you are unfamiliar with wiring, use a qualified electrician. This product conforms to UL Standard 507. WARNINGS 30 inches from blade tip to nearest wall or obstruction Must be able to secure the fan to building structure or fan-rated outlet box Know your wiring Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.
www.HunterFan.com Tools Needed Ladder Pliers Wire Strippers 9/64” Drill Bit (optional) Power Drill (optional) If mounting to a support structure, you will also need these tools. 3 M0014-01 • 02/08/16 • © 2012–2016 Hunter Fan Company Screwdrivers 1.888.830.
34O CEILING www.HunterFan.com Mounting Options OPTION 1 If you have a flat ceiling: 1. You will need a longer downrod (sold separately). 2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately).
www.HunterFan.com Ceiling Bracket 1.888.830.1326 r we o nP r Tu OFF Make sure all four bumpers are still attached. For angled ceilings, point opening toward peak. Use wood screws Use machine screws (included) when securing (provided with outlet to support structure with box) when securing to approved electrical outlet existing ceiling fan-rated box. Drill 9/64” pilot holes outlet box.
www.HunterFan.com Option 1 Downrod 1.888.830.
www.HunterFan.com KEEP! (not to scale) 8” & 3/8” 1.888.830.1326 STRIP CUT Downrod (continued) ! KEEP Remove the pre-installed setscrew so that the downrod can be inserted. The wires can be cut, but leave at least 8” extending from the top of the downrod. Hand tighten the downrod (at least 4-5 full turns) until it stops. 8” Tighten the setscrew with pliers. DO NOT HAND TIGHTEN. 3/8” If the setscrew is not tightened securely, the fan may fall.
www.HunterFan.com Downrod (continued) Put the wires and downrod through the canopy. Let the canopy sit loosely on top of the fan. DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES. Place the downrod ball into the slot in the ceiling bracket. 8 M0014-01 • 02/08/16 • © 2012–2016 Hunter Fan Company 1.888.830.
Wiring OM FR CEILIN www.HunterFan.com Note: To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist clockwise until tight. G OM FR T KE Black FR (Ungrounded) M FA N Blue FRO (Ungrounded) AC Blue ING BR Black CEIL White M Using the orange wire connectors from the hardware bag, connect the black wire (ungrounded) from the ceiling to the black and the blue wires from the fan.
www.HunterFan.com Canopy Screw Holes Position the canopy so that, when lifted into place, the canopy fits into the hanging bracket as shown. Lift the canopy into place so that the screw holes are aligned. Insert the two canopy screws found in the hardware bag. Note: Fan style may vary. 10 M0014-01 • 02/08/16 • © 2012–2016 Hunter Fan Company 1.888.830.
Blades www.HunterFan.com Blade Holes Flared Tops Blade Iron Post Align the three blade holes with the three blade iron posts. Squeeze the blade and the blade iron post together. The flared tops of the blade iron posts will be fully visible above the blade when properly assembled. 11 M0014-01 • 02/08/16 • © 2012–2016 Hunter Fan Company 1.888.830.
www.HunterFan.com Light Kit 1.888.830.1326 Notch Switch Housing Screw Partially install two of the switch housing screws found in the bag. Connect the plugs from the upper and lower switch housings. Make sure to line up the colored markings on the connectors. Want to install your fan without a light kit? Go to www.HunterFan.
www.HunterFan.com Light Kit (continued) 1.888.830.1326 Metal Plate Light Pull Chain Fan Pull Chain Globe Globe Keeper Finial Cap CONGRA T YOU’REULATIONS! DONE! Finial Install a bulb into each of the sockets. When necessary, replace with bulbs of the same wattage. Press the globe and globe keeper flush against the metal plate. Thread the light pull chain through the hole in the center of the finial cap and thread the fan pull chain through the hole in the side of the cap.
Maintenance & Cleaning r Tu r we o nP www.HunterFan.com 1.888.830.1326 Metal Plate ON Globe Globe Keeper Reverse Switch Finial Cap Finial Changing the bulbs - unscrew the finial and remove it from the threaded rod. Remove the finial cap and unscrew the globe keeper while supporting the globe with your other hand. Carefully remove the globe. Unscrew bulbs and replace with bulbs of same type and wattage. Reinstall the globe assembly.
www.HunterFan.com Troubleshooting Fan doesn’t work Excessive wobbling Noisy Operation • Make sure power switch is on. • Make sure the blades are properly installed on the blade iron posts. • Make sure that the blades are properly installed on the blade iron posts. • Turn the power off, support the fan carefully, and check that the hanger ball is properly seated. • Check to see if any of the blades are cracked. If so, replace all of the blades. • Pull the pull chain to make sure it is on.