IGSS-FMSS-0301 General Instructions Table of Contents THIS BOOKLET CONTAINS INFORMATION ON: FMSS-Remote The FMSS is a single-deck, refrigerated, self-service merchandiser, which offers additional related display when positioned in front of a “Parent” service case. General Instructions ................................................. 2 Cut & Plan Views ....................................................... 3 Installation (cont.) .................................................... 4 LEVELING...........
Rev.0301 6 1/8" 12 1/4" *24" *26" n Fa 24" 3 1/2" 12 1/2" *10 1/2" 4 1/2" 16" *Dimensions adjust at these points to match service case height FMSS Remote 2 5/8" Ref. Drop In Elec. Drain 4' Self-Service Shown with Optional Special Height (VARIABLE LENGTHS) FMSS Scale = 1" Plan View Scale = 1/2" 20" ASC PARENT CASE FMSS Height Modified to match the ASC case “Field” Close Off FMSS Front-Mount Self-Service case. Can be ordered to mount in front of ANY service case.
IGSS-FMSS-0301 Installation (cont.) LOCATION The refrigerated merchandisers have been designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75°F and 55% relative humidity. DO NOT allow air conditioning, electric fans, ovens, open doors or windows (etc.) to create air currents around the merchandiser, as this will impair its correct operation. Product temperature should always be maintained at a constant and proper temperature.
Rev.0301 Installation (cont.) (apply additional silicone if necessary). Remove tape applied on line #3. 7. To compress silicone at joint, use two Jurgenson wood clamps. Make sure case is level from front to back and side to side on inside bulkheads at joint. 8. Attach sections together with the two 3/8” bolts provided, below the deck at the mullion towards the rear of the FMSS. Remove clamps. 9. Apply bead of silicone to top of bulkheads and slip on stainless steel bulkhead cap.
IGSS-FMSS-0301 Refrigeration REFRIGERANT TYPE ELECTRONIC - The Electronic Expansion valve master and slave cylinder(s) are located within the electrical access panel(s). The standard refrigerant will be R-404 unless otherwise specified on the customer order. Check the serial plate on the case for information.
Rev.0301 back, it is the left-hand side. panel and whether the case is going to be pushed up against a wall. Attention Installer! It is contractor’s responsibility to install case(s) according to Front of Case Ballast and T-stat are located in the front left hand area of the case, viewed from customer angle. In all cases, the thermostat is located on the same side of the case. If you are looking at the case from the front, it is the right-hand side.
HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 90- 910 LIC.#: 6 06 REVISIONS: #: DESCRIPTION: 1 2 3 N BALLAST 12 -01-0681 MAGNETEK B260I120HP L1 ~ 11 VAC 0/ 0 Hz. BUNDLE COLOR ORANGE SWITCH TOGGLE 12 -01-0307 CASE CANOPY LIGHT (1) F 8T12-SPX30 DATE: BY: L1 N M VAC - 0/60 Hz. BUNDLE COLOR BROWN L1 N ~ 11 VAC - 0/60 Hz. BUNDLE COLOR BLACK / WHITE T-STAT SUCTION SOLENOID VALVE (OPTIONAL TEMPERATURE CONTROL) ADRIAN E.
HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 LIC.#: 644406 REVISIONS: #: DESCRIPTION: 1 2 3 N BALLAST 125-01-0681 MAGNETEK B260I120HP L1 ~ 115 VAC - 50/50 Hz. BUNDLE COLOR ORANGE SWITCH TOGGLE 125-01-0307 CASE CANOPY LIGHT (1) F72T12-SPX30 DATE: BY: L1 N M BUNDLE COLOR BROWN L1 N ~ 115 VAC - 50/60 Hz. BUNDLE COLOR BLACK / WHITE T-STAT SUCTION SOLENOID VALVE (OPTIONAL TEMPERATURE CONTROL) ADRIAN E.
HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 LIC.#: 644406 REVISIONS: #: DESCRIPTION: 1 2 3 N BALLAST 125-01-0681 MAGNETEK B260I120HP L1 ~ 115 VAC - 50/50 Hz. BUNDLE COLOR ORANGE SWITCH TOGGLE 125-01-0307 CASE CANOPY LIGHT (1) F96T12-SPX30 DATE: BY: L1 N M BUNDLE COLOR BROWN M L1 N ~ 115 VAC - 50/60 Hz. BUNDLE COLOR BLACK / WHITE T-STAT SUCTION SOLENOID VALVE (OPTIONAL TEMPERATURE CONTROL) ADRIAN E.
HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 LIC.#: 644406 REVISIONS: #: DESCRIPTION: 1 2 3 N BALLAST 125-01-0681 MAGNETEK B260I120HP L1 ~ 115 VAC - 50/50 Hz. BUNDLE COLOR ORANGE SWITCH TOGGLE 125-01-0307 CASE CANOPY LIGHT (1) F72T12-SPX30 + (1) F48T12-SPX30 DATE: BY: L1 N M BUNDLE COLOR BROWN M L1 N ~ 115 VAC - 50/60 Hz. BUNDLE COLOR BLACK / WHITE T-STAT SUCTION SOLENOID VALVE (OPTIONAL TEMPERATURE CONTROL) ADRIAN E.
HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 LIC.#: 644406 REVISIONS: #: DESCRIPTION: 1 2 3 N BALLAST 125-01-0681 MAGNETEK B260I120HP L1 ~ 115 VAC - 50/50 Hz. BUNDLE COLOR ORANGE SWITCH TOGGLE 125-01-0307 CASE CANOPY LIGHT (2) F72T12-SPX30 DATE: BY: L1 N M BUNDLE COLOR BROWN M M L1 N ~ 115 VAC - 50/60 Hz. BUNDLE COLOR BLACK / WHITE T-STAT SUCTION SOLENOID VALVE (OPTIONAL TEMPERATURE CONTROL) ADRIAN E.
Rev.0301 User Information 33°–35°! Set thermostat to cut in at 28° discharge air. Meat holding box: 32°. Meat prep room: 55°. Meat bloom box: 36°. 2. Temperature control should be by means of a T-Stat and Suction Stop Solenoid at each case. Do not use EPR valves, Liquid Line Solenoids or electronic control devices of any kind, as these allow temperature swings causing dehydration and excessive energy consumption. STOCKING Improper temperature and lighting will cause serious product loss.
IGSS-FMSS-0301 Soap and hot water are not enough to kill this bacteria. A sanitizing solution must be included with each cleaning process to eliminate this bacteria. 1. Scrub thoroughly, cleaning all surfaces, with soap and hot water. 2. Rinse with hot water, but do not flood. 3. Apply the sanitizing solution according to Hussmann’s directions. 4. Rinse thoroughly. 5. Dry completely before resuming operation.
Rev.0301 Specifications FMSS Medium Temp TEMPERATURE DISCHG. TYPE & AVG AIR T-STAT/ MAKE PROD DISC VELOC CUT IN EVAP. TMP TMP @FPM SETTINGS COIL BTU REQ’D PER FT. EVAP TMP 4' Remote 450 18° 6' Remote 450 18° 8' Remote 450 18° 10' Remote 450 18° 12' Remote 450 18° 35°37° 35°37° 35°37° 35° 37° 35°37° 28° 100 Optional Forced Air 28° 100 Optional Forced Air 28° 100 Optional Forced Air 28° 100 Optional Forced Air 28° 100 Optional Forced Air FAN SIZE DEFROST & FREQ.
IGSS-FMSS-0301 Appendices insulated according to Hussmann’s recommendations. 1.3 A clogged waste outlet blocks refrigeration. The installer is responsible for the proper installation of the system which dispenses condensate waste through an air gap into the building indirect waste system. 1.
Rev.0301 only in Fahrenheit shall be accurate to 2°F. The thermometer should be checked for proper calibration. (It should read 32°F when the stem is immersed in an ice water bath). b) LOCATION – The probe or sensing element of the thermometer should be located in the airstream where the air first enters the display or storage area, and not more than 1 inch away from the surface and in the center of the discharge opening.
IGSS-FMSS-0301 18
Rev.0301 Limited Warranty This warranty is made to the original user at the original installation site and is not transferable. Hussmann merchandisers are warranted to be free from defect in material and workmanship under normal use and service for a period of one (1) year from the date of original installation (not to exceed fifteen (15) months from the date of shipment for the factory). Hussmann Impact Modular Coils are warranted for a total of five (5) years based upon the above criteria.
IGSS-FMSS-0301 Service Record Last service date: By: /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit. Additional copies of this publication may be obtained by contacting: Hussmann® Chino 13770 Ramona Avenue • Chino, California 91710 (909) 628-8942 FAX (909) 590-4910 (800) 395-9229 They can be found on a small metal plate on the unit. Please note them below for future reference.