ESSS / ESS Rev.
IGSS-ESS/ESSS-0303 General Instructions Table of Contents THIS BOOKLET CONTAINS INFORMATION ON: ESSS: Refrigerated Self Service cases Matches Multideck Service Cases General Instructions ................................................. 2 Cut & Plan Views ....................................................... 3 Installation ................................................................. 4 SETTING AND JOINING .........................................................................................
Rev.
IGSS-ESS/ESSS-0303 Installation LOCATION step one. The refrigerated merchandisers have been designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75°F and 55% relative humidity. DO NOT allow air conditioning, electric fans, ovens, open doors or windows (etc.) to create air currents around the merchandiser, as this will impair its correct operation. Product temperature should always be maintained at a constant and proper temperature.
Rev.0303 Installation (cont.) Touches” section of this booklet). Fasten along the top edge, or center, with #10 x 3/4” sheet metal screws in the pre-drilled holes. ESS REFRIGERATED Inside Wedge: Line up taper pins with holes on adjoining case.Turn camlock to lock in.Two camlocks are located at the rear of the case behind the air discharge and behind the lower electrical raceway panel. Bolt the front of the wedge into the adjoining case.
IGSS-ESS/ESSS-0303 Plumbing WASTE OUTLET AND P-TRAP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. A 1-1/2" P-trap and threaded adapter are supplied with each fixture. The P-trap must be installed to prevent air leakage and insect entrance into the fixture. 3. 4. NOTE: PVC-DWV solvent cement is recommended. Follow the manufacturer’s instructions.
Rev.0303 Refrigeration REFRIGERANT TYPE The standard refrigerant will be R-22 unless otherwise specified on the customer order. Check the serial plate on the case for information. tronic expansion valves will be installed on the coil inlet, coil outlet, and in the discharge air. (Some supermarkets require a 4th sensor in the return air).
IGSS-ESS/ESSS-0303 Electrical WIRING COLOR CODE GREEN PURPLE ORANGE YELLOW RED / BLACK BLACK / WHITE BROWN GROUND ANTI-SWEAT LIGHTS RECEPTACLE T-STAT /SOLENOID230V T-STAT / SOLENOID 115V FAN MOTORS BEFORE SERVICING ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. This includes (but not limited to) Fans, Heaters, Thermostats, and Lights.
Rev.0303 Joint Trim ESSS Only (ESS dows not have joint trim) APPLY SEALANT TO SHADED AREA JOINT BACKER LOCATION CAMLOCK LOCATION CAMLOCK LOCATIONS BOLT INSIDE WEDGES SEAL AROUND PIPING ACCESS HOLES CAMLOCK ACCESS PANEL CAMLOCK & SEALANT LOCATIONS User Information STOCKING charge and return air flue must be unobstructed at all times to provide proper refrigeration. 6. There are vents located at the base of the front of the glass, just above the front rail.
IGSS-ESS/ESSS-0303 dehydration process. The only other moisture within the case is that in the product itself. A single level of meat will dry out faster than a fully loaded case of 3–4 levels of meat. 1. Scrub thoroughly, cleaning all surfaces, with soap and hot water. 2. Rinse with hot water, but do not flood. 3. Apply the sanitizing solution according to the manufacturer’s directions. 4. Rinse thoroughly. 5. Dry completely before resuming operation. IMPORTANT STEPS 1.
Rev.0303 attracts dust and dirt to the surface. Blotting with a clean damp cloth is recommended to remove charge. Step 1 ANTISTATIC COATINGS For acrylic used indoors, antistatic coatings successfully prevent the accumulation of an electrostatic charge for periods of several months—if the surface is not washed or wiped down with a wet cloth. Between applications of the antistatic coatings, the parts need only be dusted with a soft clean cloth to maintain a good appearance.
IGSS-ESS/ESSS-0303 Maintenance ELECTRICAL PRECAUTIONS be repaired in the field. Materials are available from local refrigeration wholesalers. Hussmann recommends using #15 Sil-Fos for repairs. BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component This includes (but not limited to) Fans, Heaters, Thermostats, and Lights. TIPS & TROUBLESHOOTING Before calling for service, check the following: 1.
Rev.0303 Specifications Model & Length ESS 4' 6' 8' 10' 12' ESS 45° 90° Application Deli Meat / Fish Deli Meat / Fish Deli Meat / Fish Deli Meat / Fish Deli Meat / Fish - Wedges Inside - Deli Inside - Meat Outside - Deli Outside - Meat Inside - Deli Inside - Meat Outside - Deli Outside - Meat Refrigeration Average Disch. Air T~Stat Btu / Hr. Temperatures (°F) Speed Settings (Ft.) (Total) Evap. Prod. Disch. (CFM) (°F) 550 650 550 650 550 650 550 650 550 650 Coil Type Fan Blade Qty. Defrosts Elec.
125-04-0101 (Not used) 125-04-0126 125-04-0100 (Not used) Ballats WH3-120-164 (125-04-0118) 125-04-0115 Hussmann Corporation Revisions: 13770 Ramona Avenue No. Description: Chino, CA. 91710 (909)-590-4910 Lic.
(Not used) 125-04-0101 125-04-0103 125-04-0115 125-04-0115 (Not used) (Not used) Ballast WH3-120-164 (125-04-0118) Hussmann Corporation Revisions: 13770 Ramona Avenue No. Description: 1 Added rear heater to case Chino, CA. 91710 (909)-590-4910 Lic.
125-04-0113 125-04-0101 125-04-0104 (Not used) 125-04-0115 No number yet (Not used) (Not used) Ballast WH3-120-164 (125-04-0118) Hussmann Corporation Revisions: 13770 Ramona Avenue No. Description: 1 Added rear heater to case Chino, CA. 91710 (909)-590-4910 Lic.
125-04-0113 125-04-0101 125-04-0105 (Not used) 125-04-0115 No number yet (Not used) (Not used) Ballast WH3-120-164 (125-04-0118) Hussmann Corporation Revisions: 13770 Ramona Avenue No. Description: 1 Added rear heater to case Chino, CA. 91710 (909)-590-4910 Lic.
125-04-0113 125-04-0101 Thermostat 125-04-0111 125-04-0106 125-04-0115 125-04-0115 Ballasts WH3-120-164 (125-04-0118) Hussmann Corporation Revisions: 13770 Ramona Avenue No. Description: 1 Added rear heater to case Chino, CA. 91710 (909)-590-4910 Lic.
125-04-0113 125-04-0101 Thermostat 125-04-0111 125-04-0107 Hussmann Corporation 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 Case to Case Harness Single case Pigtail Ballast Extension Box (Switched Power) GFCI Dedicated Line 125-04-0113 125-04-0113 125-04-0114 Duplex Receptacles Light Switch 125-04-0100 Revisions: No.
IGSS-ESS/ESSS-0303 Appendices APPENDIX A. – Temperature Guidlines insulated according to the manufacturer’s recommendations. 1.3 A clogged waste outlet blocks refrigeration. The installer is responsible for the proper installation of the system which dispenses condensate waste through an air gap into the building indirect waste system. 1.
Rev.0303 only in Fahrenheit shall be accurate to 2°F. The thermometer should be checked for proper calibration. (It should read 32°F when the stem is immersed in an ice water bath). b) LOCATION – The probe or sensing element of the thermometer should be located in the airstream where the air first enters the display or storage area, and not more than 1 inch away from the surface and in the center of the discharge opening.
IGSS-ESS/ESSS-0303 22
Rev.0303 Limited Warranty This warranty is made to the original user at the original installation site and is not transferable. Hussmann merchandisers are warranted to be free from defect in material and workmanship under normal use and service for a period of one (1) year from the date of original installation (not to exceed fifteen (15) months from the date of shipment for the factory). Hussmann Impact Modular Coils are warranted for a total of five (5) years based upon the above criteria.
IGSS-ESS/ESSS-0303 Service Record Last service date: By: /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit. Additional copies of this publication may be obtained by contacting: Hussmann® Chino 13770 Ramona Avenue • Chino, California 91710 (909) 628-8942 FAX (909) 590-4910 (800) 395-9229 They can be found on a small metal plate on the unit. Please note them below for future reference.