DATE:
PROJECT TITLE:
DRAWING #:
DRAWN BY:
PRODUCTION ORDER #:
DRAWING TITLE:
DATE:
Hussmann Corporation, Int'l.
13770 Ramona Avenue
Chino, CA. 91710
(909)-590-4910 Lic.#: 644406
REVISIONS:
#: DESCRIPTION:
CHECKED BY:
BY:
FILE LOCATION:
JESSE RIOS
PAGE OF
?
1
1
6/27/07
R3
W1800173
R3-P-6-REM
914522
L
BALLAST 125-01-3266
FULHAM LH3-120-L
RJ-45 NETWORK JACK
125-01-0202
LIGHT CIRCUIT= 0.7A
F21T5-36"
125-03-1128
FAN MOTOR
0.29 AMP @ 120VAC
(2) 0392457
M
M
SENSOR
225-01-3072
BUNDLE
BROWN
LABELED
FAN CIRCUIT
T-STAT
(1) 225-01-0710
SUCTION SOLENOID
(1) 225-01-3206
BUNDLE
WHITE/BLACK
LABELED
THERMOSTAT
CIRCUIT
~120 VAC - 60 Hz
N L1
MCA= .88A
MOP= 15A
BLACK #14
WHITE #14
~120 VAC - 1Ø - 60 Hz
~120 VAC - 60 Hz
MCA= 0.65A
MOP= 15A
BUNDLE
ORANGE
LABELED
LIGHT CIRCUIT
L1 N
L1 N
BLACK #14
WHITE #14
BLACK #14
WHITE #14
WARMER (6ft)
125-01-0767
TYCO
THERMAL
CONTROLS
10BTV1-CR
60 WATTS
0.5AMP@120V
BUNDLE
PURPLE
LABELED
HEATER
CIRCUIT
LI N
~120 VAC - 1Ø - 50/60 Hz.
MCA= .63A
MOP= 15A
BOHN COIL ASSY
(1) VA-012 120V 1.6A
225-02-133
MCA= 2.0A
MOP= 15A
LIGHT SWITCH
TIPPETTE
125-01-0311
INCOMING POWER
~120 VAC -60 Hz
GFCI
DUPLEX
125-01-3178
NOTE FOR GFCI PROTECTION: IF MORE THAN ONE
SINGLE RECEPTACLE IS USED IN CONJUNCTION WITH
A GFCI DUPLEX RECEPTACLE "DOWNSTREAM" ON
THE LOAD SIDE, THE SUM OF ALL RECEPTACLES
SHOULD NOT BE MORE THAN 15A
LOAD SIDE POWER
~120 VAC -60 Hz
125-01-0443
BLK # 14
WHT # 14
GRN # 14
ALL SINGLE
RECEPTACLES TO BE
TIED TO DUPLEX
GFCI RECEPTACLE
BUNDLE
YELLOW
LABELED
RECEPTACLE
CIRCUIT
15.0
L1
L2
L3
120 V
LOADING
CIRCUIT # 2 (optional)
BALLAST 125-01-3266
FULHAM LH3-120-L
F21T5-36"
125-03-1128
F21T5-36"
125-03-1128
F21T5-36"
125-03-1128
LOADING
120 V
L1
L2
L3
3.4
NOTE:
CASE MUST
BE GROUNDED
CIRCUIT #1
Wiring Diagrams (Cont'd)