16. Installing the front on the heat storage compartment (4). Place the front on the heat storage compart-
ment and fasten with the four screws (5).
An accessory top cover is available to cover the hole in the stove top plate if the smoke outlet is connected
at the rear of the stove.
Fitting the loose parts
Before the stove is installed, you must ensure that all loose parts are fitted correctly. Make sure that the
chimney is tight and that no false draft is caused around neither the cover plate, in connection with a
covered smoke outlet, nor the cleanout door and pipe connections. Please note that bent and/or hori
-
zontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of the stoves (Drawing B)
B1: HWAM 3630, HWAM 3640
B2: HWAM 3650, HWAM 3660
1. Smoke shelf. Must be placed on the steel rail and the holder at the front in the middle.
2. The baffle plate is suspended on three hooks beneath the top plate. One of the hooks has an additional
flap that is bent upwards as protection during transport. This flap should be removed with the help
of a screwdriver before installation.
3. The rear smoke outlet has been closed at the factory by screwing a plate over it and it is therefore
hidden behind the rear plate.
4. Removable rear plate. This must always be mounted if the stove is placed next to a combustible wall.
5. Loose heat shield. This must always be mounted if the stove is placed next to a combustible wall.
6. Loose heat shield beneath the ash pan. Can be used as a lid when the ash pan is removed for emptying.
Connection to chimney
All the stoves have both rear and top smoke outlet that can be connected to an approved steel chimney on
top or directly out at the rear to a chimney.
Make sure that the chimney is tight and that no false draft is caused around neither the cover plate, in
connection with a covered smoke outlet, nor the cleanout door and pipe connections. Please note that
bent and/or horizontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of smoke flue (Drawing C):
C1: Top smoke outlet
C2: Rear smoke outlet
1. Steel chimney.
2. Flue gas elbow. Fits into smoke flue socket.
3. Brick-built jamb of flue.
4. Built-in pipe sleeve. Fits smoke flue.
5. Wall rosette. Covers disruption to wall around pipe sleeve.
6. Joint. Sealed with packing material.
7. Smoke outlets of the HWAM stove.
8. Cover plate in the external rear plate – break off if a rear outlet is required.
9. Cover screwed in position: secure it to the top plate with screws if a rear outlet is required.
10. Smoke bushing: to be screwed to the back of the stove if a rear outlet is required.
11. Adjusting damper in smoke pipe.
12. Cleaning hatch.
13. Smoke pipe to rear outlet.
14. Loose cast iron cover: to be placed on the top plate when there is a rear outlet.