Guarantee
The guarantee does not cover damage due to insufficient maintenance!
Maintenance Warnings
If a maintenance warning goes off, you can continue using the wood-burning stove, but contact your dealer
as soon as possible. Your stove could be affected by impure combustion.
opErAtionAl problEMS
Blackened glass
The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture
level not exceeding 18% RH.
The door gasket may be leaking.
Smoke in the room when opening door
The grate in the chimney may be closed. Open the grate.
• Insufficient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or refit.
• Never open the door when there are still flames on the wood.
Uncontrollable combustion
• Faulty seal in door. Fit new seal.
Safety Alarms