User Manual HWAM® SmartControl™ Generation 2 EN Wi-Fi Frequency: 2.4 GHz. 17.01.2019 / 53-1102 www.hwam.
CONTENTS Installation instructions Introduction to HWAM® SmartControlTM Before using HWAM® SmartControlTM First setup Connecting to Wi-Fi networks 3 3 3 4 6 Operating instructions IHS SmartControlTM app* Startup - app Home screen / front Night reduction Phase indication Stoking time Flue gas temperature, room temperature, temperature level Home Screen - Live data IHS SmartControlTM - messages IHS SmartControlTM - menu Alarms & Warnings Room temperature sensor Pairing of the room temperature sensor with HW
INSTALLATION INSTRUCTIONS Introduction to HWAM® SmartControlTM The following sections will provide an introduction to the HWAM® SmartControl™ app named IHS SmartControl™ and the associated wireless room temperature sensor, and how they operate.
First Setup Introduction The following sections describe how the HWAM® SmartControl™ is connected to a Wi-Fi network or via Wi-Fi Direct. It is always best to connect the system to a Wi-Fi network, as this ensures the best connection to the system and the simplest operation. It is not necessary to connect to the Internet in order to use HWAM® SmartControl™ or HWAM® SmartStove™ on a wireless network.
Connection icons 1 1 No connection (red Wi-Fi icon) 2 Wi-Wi-Fi Direct connection (green Wi-Fi icon) 3 Connected through the network (green Wi-Fi icon 2 with a tick) HWAM® SmartControl™ can be used by directly connecting the device and HWAM® SmartControl™, also called Wi-Fi Direct, displayed by a green symbol. HWAM® SmartControl™ can also be configured to connect through a Wi-Fi network, which is recommended. This connection is indicated by a green symbol with a tick.
1 Connecting to Wi-Fi networks After the mobile device is connected via Wi-Fi Direct, HWAM® SmartControl™ can be connected to a Wi-Fi network. To connect a Wi-Fi network, press the green connection icon 1 . If you wish to connect HWAM® SmartControl™ to the network, click "Yes" 2 . This is recommended. Enter the name of the stove for example: "Living room" or "First floor." 3 21 NOTE: The name is used primarily when there are multiple stoves connected to the same network.
OPERATING INSTRUCTIONS IHS SMARTCONTROL™ APP Startup - app When the IHS SmartControl™ app is started, the IHS logo is displayed: IHS SmartControl™ Main Screen / Front: 2 1 3 1 8 1 App Menu 2 Status Icon (Connection) 3 Stove Name 4 Night Reduction 5 Phase Indication 6 Restoking Timer 7 Flue Gas Temperature 8 Room Temperature 9 Temperature Level Home screen / Front page The following section comprises the home screen / front page of IHS SmartControl™ app which describes which features are available and
3 Stove name The stove name displays the name of the stove connected to the IHS SmartControl™ app. This is used in the case where several stoves are connected to the same network. If the stove has not previously been connected to a network, it will have no name and nothing will be displayed. 4 A Night reduction Active (green) B 3 A B Inactiv (black) To activate / deactivate the night reduction press the icon.
B Lighting up The phase indicator shows that the system is in the lighting up phase. The symbol is displayed after the door has been opened on a cold stove, or in the case where the standby / start icon of the IHS SmartControl™ app has been pressed. If the flue gas temperature does not increase within 15 minutes, the HWAM® SmartControl™ will automatically shut off the air supply and return to standby mode. See the section on correct firing process on page 20.
E Standby The phase indicator shows that the system is in standby mode. This means that the system has been in use, and that the temperature in the stove is now so low that it cannot be guaranteed that the stove can light new wood. It is therefore necessary start anew if you want to burn more wood. E REMEMBER: Never leave a stove after igniting a fire before ensuring that there are long lasting flames! 6 Stoking time The stoking time shows the estimated time to the next stoking.
Level 0 (No bar is yellow) The temperature level is set to "Level 0". HWAM® SmartControl™ runs at the lowest possible combustion temperature to maintain proper combustion for the longest period of time possible, irrespective of the room temperature. Level 1-4 (1-4 bars are yellow) The temperature level is set to "Level 1- 4". At these levels the HWAM® SmartControl™ runs with the purpose of reaching a temperature in the room that remains as constant as possible, just like a radiator thermostat.
IHS SmartControlTM - messages Updating the HWAM® SmartControl™ IHS SmartControl™ is automatically notified when a new update for HWAM® SmartControl™ is available. To update your system, select "Yes" 1 . If you do not wish to update, select "No" 2 . 2 Each time the app is opened, it will automatically check to see if there is an updated version available. NOTE: It is recommended that you always update the system to include the last new software, as this ensures the best functionality of the system.
IHS SmartControlTM - menu The menu of the app IHS SmartControl™ contains a number of menu items offering additional information and options that are not available from the home screen. 1 1 Menu 1 The menu is available in the upper left corner of IHS SmartControl™. 2 Statistics Statistics show a log with data from the combustion from around the last 40 hours. It is possible to go back and look at the temperature of the stove during burning, and for how long it was on, amongst other things.
3 Tips The "Tips" menu contains a number of tips and other relevant information about the stove and its operation. 3 The content is updated regularly with new information, and you are encouraged to look here regularly. 4 Time management At the start time selected A , the HWAM® SmartControl™ automatically goes into night reduction mode to achieve the longest possible burning. At the same time, the room temperature function in the HWAM® SmartControl™ is disabled.
Settings: Wi-Fi Here you can see to which network the HWAM® SmartControl™ is connected. To reset this, for example, if you want to connect to another network, select "Reset Wi-Fi settings" A . Settings: Update firmware If a new update is available, this will be shown in the menu "Update firmware". To update HWAM® SmartControl™ to the most recent version, press the button with "Update to V x.x.
7 Stoves If there are more than one stove connected on the network A , it is also possible to communicate with them. The system supports 4 stoves on the same network. In the "Stoves" menu, select the stove you want to communicate with. A NOTE: Only stoking alarms for the selected stove will be emitted. Alarms & Warnings The HWAM® SmartControl™ can provide a number of alarms and warnings along with the possible causes underlying the problem. It is also possible to see if there are errors in the system.
Room temperature sensor A room temperature sensor is provided as a standard with the HWAM® SmartControl™. This is used by the system to detect the room temperature and adjust the combustion in order to ensure an even and comfortable room temperature. The sensor communicates with HWAM® SmartControl™ via a wireless connection. The maximum distance in clear view between the HWAM® SmartStove™ and the room temperature sensor is 4 -5 metres. The range is shorter if there are walls in between.
Pairing of the room temperature sensor with HWAM® SmartControl™ It may sometimes be necessary to pair the wireless room temperature sensor with HWAM® SmartControl™. To do this, it is necessary to put the wireless room temperature sensor in pairing mode (see instructions below). 1 Turn the unit on its rear end. 2 Unscrew the four screws on the backside (as shown 3 4 5 6 in the picture) to access the batteries. Remove the lid from the unit. Take one battery out of the unit.
Changing the batteries of the room temperature sensor The wireless room temperature sensor requires 3 AA batteries. These are not included in the package. In order to install and / or replace the batteries, follow these instructions carefully. HWAM® SmartControl™ will automatically notify you when it is time to replace the batteries in the wireless room temperature sensor. 1 Turn the unit on its rear end. 2 Unscrew the four screws on the backside (as shown 1 in the picture) to access the batteries.
Firing process The following guide is an introduction as to how the HWAM® SmartStove™ is to be operated from start to restoking and until the fire finally burns out. The stove is only EN-approved for burning wood. It is recommended that you use dry split wood with a moisture content of a maximum of 18%. Firing wet firewood causes soot, environmental pollution and bad fuel economy.
Combustion phases 1 Lighting up 1 2 Combustion 2 3 Ember phase 3 The lighting up symbol is displayed until the fire is well underway and the flue gases have reached a sufficiently high temperature. When a sufficient flue gas temperature is reached, HWAM® SmartControl™ changes phase from lighting up to combustion. HWAM® SmartControl™ will typically run in this phase most of the time.
4 Restoking 4 5 Standby 5 When HWAM® SmartControl™ detects that it is time to restoke, a notification is displayed on all devices with IHS SmartControl™ open. In addition, the wireless room temperature sensor emits an audible signal for restoking. Add 2-3 pieces of new wood to the combustion chamber. HWAM® SmartControl™ will automatically switch back to the combustion phase when the door is opened and additional wood is added. The above cycle is then repeated.
Specifications for HWAM® SmartControlTM generation 2 Wireless features Frequency 2.4-2.4835GHz Wireless security WPA / WPA-2 Wireless standards IEEE 802.11n, IEEE 802.11g, IEEE 802.11b 5GHz Not available Distance Distance between stove and sensor 4-5 m.
HWAM® SmartStove™ - A whole new class of wood-burning stoves HWAM A/S . Nydamsvej 53 . DK-8362 Hørning . hwam@hwam.com . www.hwam.