User Manual HWAM® SmartControl™ Generation 2

9
D
C
B
B
Lighting up
The phase indicator shows that the system is in
the lighting up phase. The symbol is displayed
after the door has been opened on a cold stove,
or in the case where the standby / start icon of the
IHS SmartControl™ app has been pressed. If the
flue gas temperature does not increase within 
minutes, the HWAM® SmartControl™ will automat-
ically shut o the air supply and return to standby
mode. See the section on correct firing process on
page .
NOTE: To ensure complete combustion e-
ciency it is important to obtain a suciently
high flue gas temperature. Failing this, HWAM®
SmartControl™ emits a restoking alarm, even if
there is unburned wood and flames.
C
Combustion
The phase indicator shows that the system is in
the combustion phase and has exited the light-
ing up stage. The system automatically regulates
combustion, ensuring optimum combustion and a
room temperature as close to the desired level as
possible.
D
Ember phase
The phase indicator shows that the system is in
ember phase. In this phase there will be mainly
only embers in the stove, and the system will now
also be able to calculate the expected time for the
next restoking (described in a following section).
The system automatically gives an alert regarding
the correct restocking time. It is recommended that
you wait before restoking until the restoke alarm is
emitted, as the expected firewood saving is oth-
erwise not achievable. If there is a big dierence
between actual and desired room temperature,
the restoking alarm comes on, even though there
is unburned wood and flames. Failure to restoke at
this time, will lead to a new restoking alarm being
emitted, which constitutes the last opportunity to
restoke without new lighting up.
NOTE: The best and most economical combus-
tion is achieved by following the recommended
stoking time carefully.