User's Manual

Managing Your iControl Devices
7. Click on the ‘Add’ button. You will be returned to the System window and
your newly-added CO detector will appear in the list of devices.
8. Next, physically install the device by simply plugging the sensor in to any
wall outlet. Once installed, the green Power LED comes on immediately. If
it does not, check that the outlet is not controlled by a wall switch—
iControl recommends using an outlet not controlled by a wall switch, as
this may result in the device being inadvertently turned off.
The iControl box discovers the CO detector within about 70 minutes of its initial
installation. As soon as your System ‘sees’ your Carbon Monoxide detector, the yellow
dot adjacent to its name on your System page will turn green. If the yellow dot next to the
name of the alarm does not turn green, repeat the installation process, making sure to
enter the correct device type and ID.
After installation, test the device by pressing the ‘Test/Reset’ button. The device should
chirp loudly and the red LED should flash red. You should also see an alarm in the Alarm
History window on your Summary page.
Note:The CO detector should not be used as a smoke or fire detector and is not suitable
for installation in hazardous locations, as defined by public building codes.
To operate properly, a CO detector needs to be placed with the following considerations
in mind:
x Place within 100 feet of your iControl box.