rangeguide Commercial & Industrial Boilers & Radiators www.idealcommercialboilers.
contents Boilers Radiators Condensing icos HE Stelrad Radiators 4 22 W 5 plus II 6 Traditional xtra 7 Elite 24 Concord CXC 8 Compact 25 GT Condenser 9 Low Surface Temperature Gas Atmospheric LST Standard 26 LST Plus 27 Concord CXA/H S/H 10 Concord Modular 11 Concord CXSi/H 12 Specifier Range Concord ES/H 13 Style 28 Planar 29 Concord 30 High Efficiency Super Series 4 14 Super Plus 15 Radiator Options 31 Pressure Jet 2 Buccaneer GTE 16 Falcon GTS 17 Harrier
Ideal Boilers Ideal Boilers is one of the most respected names in the UK Commercial and Domestic heating industry. We design and develop ranges to suit the ever changing UK marketplace. With the market’s continued move towards condensing products, Ideal launched the condensing range. The recent addition of the xtra maintains Ideal’s position as the market leading supplier in the Commercial and Industrial boiler sector.
condensing icos HE 30 + 36kW • Wall mounted • Robust cast aluminium heat exchanger • Compact • Easy to install and service • Modulating output down to 10.4kW • Wide range of flue options • Optional remotely mountable user controls General Data icos HE (30 + 36) Model 30 36 Boiler Output (condensing) 50/30˚C 11.4 - 32.8 11.4 - 39.8 Boiler Output (non-condensing) 80/60˚C 10.4 - 30.1 10.4 - 37.
W 45 - 80kW • Natural gas and propane • Single unit or modular configuration, wall or frame mounted • Robust cast aluminium heat exchanger • Easy to install and service • Simple UK voltage system controls wiring • Modulating output down to 13kW • Wide range of flue options General Data Model Boiler output (condensing) W (45 - 80) W45 W45P W60 W60P W80 W80P 13.9 - 46.9 13.7 - 45.9 13.9 - 62.3 13.6 - 60.6 21.3 - 82.7 20.7 - 80.0 50/30˚C Boiler output (non-condensing) 12.6 - 43.7 12.6 - 58.
condensing plus II 90 - 310kW • Range of six models • Compact size - small footprint • High modulation - Close load matching (all models down to 11.6kW) • 108.
xtra 80 - 560kW • Robust cast aluminium heat exchanger • In-built commissioning and fault diagnostics • Low NOx emissions • Volt free contacts supplied as standard • Meets Building Regulations 2006 (Part L2) Extended Output Range • Compact size - small footprint • Fully modulating operation down to 20% of output • Up to 107.
condensing Concord CXC 48 - 116kW • Natural gas fired condensing boiler • Meets Building Regulations 2006 (Part L2) • Fully condensing high efficiency 85% at 80˚C, 93% at 60˚C flow • Compact space saving design • Full automatic ignition • Advanced electronic controls General Data Concord CXC (48 - 116) Model Boiler output (condensing) 50/30˚C Boiler output (non-condensing) 80/60˚C 48 70 94 116 48.83 69.84 93.65 116.25 44.63 63.84 83.60 106.
GT Condenser 199 - 1096kW • Up to 16% extra heat • Compact space saving design • Adjustable flue and system connections • Low flue and system resistances • High insulation levels • Fanned or standard versions • Suitable for Harrier, Viceroy and Viscount boilers General Data GT Condenser (199 - 1096) Model RCI 300 RCI 300V RCI 400 RCI 400V RCI 500 RCI 500V Output (kW) 180 - 450 230 - 670 390 - 986 Height (mm) 1687 1777 1883 Width (mm) 610 698 830 1156 1250 1376 300 350 400 Depth (mm) (
gas atmospheric Concord CXA/H S/H 40 - 120kW • Ultra reliable gas atmospheric boilers • High, full and part load efficiencies meets Building Regulations 2006 (Part L2) • Auto ignition • Remote indication kit options • CXA/H natural gas or propane CXA P/H (40-100kW) • CXA/H is On/Off and CXS/H is High/Low operation General Data Concord CXA/H S/H (40 - 120) Model 40/H 50/H 60/H 70/H 80/H 90/H 100/H 110/H 120/H 3 4 4 5 5 6 6 7 7 40 50 60 70 80 90 100 110 120 1212 1212 1385 1385
Concord Modular 80 - 720kW • Suitable for Concord CXA/H and CXS/H models • Multiple installation outputs from 80-720kW • All servicing and maintenance from the front of boilers • Large clean-out cover for full access to flueways • Standard boiler width: 600mm • Factory assembled and tested units • Sequencer control kit available • Remote indication kit options General Data Concord Modular (80 - 720) Model 40/H 50/H 60/H 70/H 80/H 90/H 100/H 110/H 120/H No.
gas atmospheric Concord CXSi/H 110 - 180kW • Ultra reliable gas atmospheric boilers • High, full and part load efficiencies meets Building Regulations 2006 (Part L2) • Auto ignition • Remote indication kit options • High/Low operation General Data Concord CXSi/H (110 - 180) Model Sections Output (kW) 110/H 120/H 140/H 160/H 180/H 7 7 8 9 10 110 120 140 160 180 Height 1000 Width 1107 1107 1230 1353 1476 Depth 1036 1036 1036 1086 1140 250 300 Flow/Return Connections (mm) Flow
Concord ES/H 140 - 380kW • High/Low adjustable operation on all models • High, full and part load efficiencies meets Building Regulations 2006 (Part L2) • Assembled or unassembled heat exchanger availability • Robust cast iron heat exchanger • Easy to install and service • Low return temperature capability General Data Concord ES/H (140 - 380) Model 140/H 160/H 180/H 200/H 220/H 260/H 300/H 340/H 380/H 8 9 10 11 12 14 16 18 20 140 160 180 200 220 260 300 340 380 Height 1406 14
high efficiency Super Series 4 50 - 600kW • Vertical and horizontal models • High efficiency 85% (gross) • Low NOx emissions (class 5) • 50kW Modules • Sequence controlled • Compact size • Complete package gas/water headers General Data Super Series 4 (50 - 600) Model 50/V 100/V 150/V 150/VA 200/V 250/V 250/H 300/V 300/H 350/V 400/V 450/V 450/H 500/V 500/H 550/V 550/H 600V Modules 1 2 3 3 4 5 5 6 6 7 8 9 9 10 10 11 11 12 12 Output (kW) 50 100 150 150 200 250 250 300 300 350
Super Plus 200 - 600kW • Horizontal assembly • High efficiency 85% (gross) • Low NOx emissions (class 5) • 100kW Modules • Ultra compact • Sequence controlled • Easy to install and service General Data Super Plus (200 - 600) Model 200/S 300/3 300/3A 400/4 400/4A 500/5 600/6 2 3 3 4 4 5 6 200 300 300 400 400 500 600 Height 1800 1900 1900 1900 1900 1900 1900 Width 910 1510 2115 1510 2115 2115 2115 Depth 990 990 990 990 990 990 990 65 125 125 125 125 125 125
pressure jet Buccaneer GTE 21 - 39kW • Natural gas, oil fired or dual fuel • High efficiency • Minimal emissions • Compact size • Comprehensive control • Low temperature operation General Data Buccaneer GTE (21 - 39) Model Sections Output (kW) GTE 4 GTE 5 GTE 6 4 5 6 21 - 27 27 - 33 32 - 39 Height (mm) 835 Width (mm) 570 Depth (mm) 812 939 R11/4 Flow/Return Connections (BSP) Maximum Working Pressure (bar) 4 Flue Size (mm) 125 125 153 Water Content (L) 24.5 30.0 35.
Falcon GTS 40-100kW • Natural gas or oil fired • High efficiency • Minimal emissions • Compact size New Model • Comprehensive control • Low temperature operation General Data Falcon GTS (40 - 100) Model Sections Output (kW) GTS 4 GTS 5 GTS 6 GTS 7 GTS 8 4 5 6 7 8 40-50 50-64 64-78 78-92 92-100 Height 1100 Width 520 Depth 772 899 1026 1153 1280 Flow/Return Connections (BSP) R11/4 R11/4 R11/2 R11/2 R11/2 Maximum Working Pressure (bar) Flue Size (mm) Water Content (L) Approx
pressure jet Harrier GTE 105 - 330kW • Natural gas, oil fired or dual fuel • High efficiency • Minimal emissions • 3 pass heat exchanger • Compact size • Meets Building Regulations 2006 (Part L2) General Data Harrier GTE (105 - 330) Model Sections Output (kW) GTE5 GTE6 GTE7 GTE8 GTE9 5 6 7 8 9 140 180 230 280 330 1631 1791 200 200 Height 1297 Width 796 Depth 1151 1311 Flow/Return Connections (DN flange) Flue Size (mm) 65 180 180 Maximum Working Pressure (bar) 200 6 Water Con
Viceroy GT 300 - 780kW • Natural gas, oil fired or dual fuel • High efficiency • Minimal emissions • 3 pass heat exchanger • Compact size • Meets Building Regulations 2006 (Part L2) General Data Viceroy GT (300 - 780) Model Sections Output (kW) GT8 GT9 GT10 GT11 GT12 GT13 GT14 8 9 10 11 12 13 14 390 450 540 600 670 720 780 Height 1695 Width 1000 Depth Flow/Return Connections (mm) Flue Size (mm) 1505 1665 1825 1985 2145 2305 2465 75 75 75 100 100 100 100 250 250 25
pressure jet Viscount GTE 754 - 1450kW • Natural gas, oil fired or dual fuel • Meets Building Regulations 2006 (Part L2) • Minimal emissions • 4 pass heat exchanger • Comprehensive control • Low temperature return General Data Viscount GTE (754 - 1450) Model GTE14 GTE15 GTE16 GTE17 GTE18 GTE19 GTE20 GTE21 GTE22 GTE23 GTE24 GTE25 Sections 14 15 16 17 18 19 20 21 22 23 24 25 Output (kW) 812 870 928 986 1044 1102 1160 1218 1276 1334 1392 1450 Height 1760 Width 1172 D
Vanguard L 130 - 3500kW • Steel shell construction • Natural gas, oil fired or dual fuel • One or two stage operation • High efficiency 91% net (82% gross) • Reverse flame combination chamber design • Easy to install and service • Meets Building Regulations 2006 (Part L2) General Data Vanguard L (130 - 3500) Model 170 240 290 340 420 510 630 760 870 970 1100 1320 1570 1850 2200 2650 3000 3500 Output (kW) 170 240 290 340 420 510 630 760 870 970 1100 1320 1570 1850 2200 265
Stelrad Radiators Stelrad Radiators Stelrad is the UK market leader in central heating radiators, offering the widest range, and in more sizes, than any other manufacturer. Our highly advanced production and distribution facility in Mexborough, UK, produces over 2.5 million steel panel radiators a year, for both Domestic and Commercial markets.
quality, choice & style Ladder & Mini Ladder STR Bergamo • 28 Models • 5 Models • 6 Models • Heights 698 - 1800mm • Heights 645, 745mm • Heights 740, 1172, 1730mm • Lengths 400, 500 & 600mm • Lengths 425, 625, 825mm • Lengths 500, 600mm • Output 240 - 1022 watts • Output 419 - 922 watts • Output 376 - 940 watts • Types Straight/Curved - • Functional and aesthetically • New flat tube design White/Chrome • Cost effective • Adds elegance superior Vertex Classic Column •
Traditional Elite Data & Dimensions Length (mm) (mm) ⵜ 24 Height Output Watts at Δ T50 K1 P+ K2 P1 300 500 259 388 506 • 300 1000 517 776 1012 • 300 1500 776 1164 1518 • 300 2000 1034 1552 2024 • 300 2500 1293 1940 2530 • 300 3000 1551 2328 3036 • 450 400 307 442 564 190 450 500 384 553 705 238 450 600 461 664 845 286 450 700 538 774 986 333 450 800 614 885 1127 381 450 900 691 995 1268 428 450 1000 768 1106 1409 476 45
Compact Data & Dimensions ⵜ Height Length Output Watts at Δ T50 (mm) (mm) K1 P+ K2 P1 300 500 255 373 491 • 300 1000 509 745 982 • 300 1500 764 1118 1473 • 300 2000 1018 1490 1964 • 300 2500 1273 1863 2455 • 300 3000 1527 2235 2946 • 450 400 302 422 548 190 450 500 378 528 686 237 450 600 454 633 823 284 450 700 529 739 960 332 450 800 605 844 1097 379 450 900 680 950 1234 427 450 1000 756 1055 1371 474 450 1100 832
low surface temperature Data & Dimensions ⵜ Height Emitter Length Output Watts at Δ T50 (mm) Height (mm) K1 P+ K2 LST Standard (mm) 500 300 560 196 284 348 500 300 760 293 426 522 500 300 960 391 568 696 500 300 1160 489 710 870 500 300 1360 587 852 1044 500 300 1560 685 994 1218 500 300 1760 782 1136 1392 500 300 1960 880 1278 1566 650 450 560 290 386 478 650 450 760 435 580 717 650 450 960 580 773 956 650 450 1160 725 966 1
Data & Dimensions Integral Kick Grille Optional Kick Grille Optional Kick Grille Length (mm) Emitter Length (mm) ⵜ Model Height Height Emitter (mm) inc Kick Grille Height (mm) (mm) Output Watts at Δ T50 K1 P+ K2 500 500 300 650 400 203 290 500 500 300 850 600 304 435 542 500 500 300 1050 800 406 580 723 500 500 300 1250 1000 507 725 904 500 500 300 1450 1200 608 870 1085 500 500 300 1650 1400 710 1015 1266 500 500 300 1850 1600 811 1160 1446 500
specifier range Style Data & Dimensions - Style Length (mm) (mm) ⵜ Height Output Watts at Δ T50 K1 K2 P+ P2 300 500 225 435 • • 300 1000 450 869 • • 300 1400 630 1217 • • 300 2000 900 1738 • • 500 400 290 514 • • 500 600 436 772 • • 500 800 581 1029 • • 500 1000 726 1286 • • 500 1200 871 1543 • • 500 1400 1016 1800 • • 500 1600 1162 2058 • • 500 1800 1307 2315 • • 500 2000 1452 2572 • • 600 400 339 597 • • 600 600
Data & Dimensions Length (mm) (mm) ⵜ Height Output Watts at Δ T50 K1 Planar K2 300 500 235 465 300 1000 469 929 300 1400 657 1301 300 2000 938 1858 400 400 250 471 400 600 376 706 400 800 501 942 400 1000 626 1177 400 1200 751 1412 400 1400 876 1648 400 1600 1002 1883 400 1800 1127 2119 400 2000 1252 2354 500 400 310 564 500 600 464 847 500 800 619 1129 500 1000 774 1411 500 1200 929 1693 500 1400 1084 1975 500 1600 1238
data & dimensions Data & Dimensions - Plane Height Length (mm) (mm) 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 588 588 588 588 588 588 588 588 588 588 588 588 588 588 588 588 588 736 736 736 736 736 736 736 736 736 736 736 736 736 736 736 736 736 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 500 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800
radiator options Valves 3/4” Adaptor Stelrad can offer a range of The adaptor enables you to luxury valves to complement connect to 3/4” pipework with our design products. no detriment to performance. Extension Pieces 20/30 and 40mm extension Floor Standing Brackets pieces are available to help When wall space is at a bridge gaps on replacement premium or has insufficient installations. load bearing, floor standing brackets can offer a suitable alternative.
The Ideal Commercial Range Boiler output kW 20 40 100 150 200 600 800 1000 1500 3500 Btu/h (000) 68 136 340 511 682 2047 2729 3412 5118 11942 Atmospheric Boilers Concord CXA/H 40-120 Concord CXS/H 40-120 110-180 Concord CXSi/H 140-380 Concord ES/H 80-720 Concord Modular High Efficiency Boilers 50-600 Concord Super Series 4 Concord Super Plus 200-600 Condensing Boilers icos HE 30-36 45-80 W Concord CXC 48-116 90-310 plus II 80-560 xtra GT Condenser 180-990 Pressure Jet