UL File No. E5238 Page 1 UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. IDEAL Wire-Nut® Wire Connectors Model 300 Volt Maximum 1 #14 1 #16 w/1 or 3 #22 71B® 1 or 2 #16 1 #16 w/1 #20 w/1 #18 or #20 Strip solid 1 #18 str. 1 #18 w/1 or 3 #20 wires ¼” 2 or 3 #18 1 #18 w/1 or 4 #22 (6,5mm); 2 or 4 #20 1 or 2 #18 w/1 #20 w/1 #22 Strip 2 #22 str.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 2 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 3 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. IDEAL Wire-Nut® Wire Connectors Model 300 Volt Maximum 2 #8 str.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 4 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 5 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. (11mm) for 4 #10 AWG Str.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 6 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. Strip wires ½” 4 #12 sol 1 or 5 #14 1 #16 str. 2 or 6 #16 2 or 6 #18 2 or 6 #20 1 #10 w/1 #8 1 #12 w/1 or 2 #10 1 #12 w/1 #8 2 #12 w/1 #10 1 #14 str. w/1 or 2 #12 str.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 7 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 8 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. IDEAL UnderGround™ Wire Connectors Model 1 or 3 #10 or #12 64® 2 or 4 #14, #16 or #18 sol. Strip wires 3 or 4 #20 solid or 22 sol.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 9 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 10 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 11 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. smaller 3/8” Model WT4 Strip wires 3/8”; strip wires #16 and smaller 7/16” 1 #14 w/2 #16 1 #14 w/3 #18 1 #14 w/4 #20 4 #16 w/1 #20 or #22 3 #16 w/1 #18 3 #16 w/1 or 2 #20 or #22 2 #18 w/3 #22 1 #18 str. w/5 #22 str.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 12 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 13 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 14 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 15 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. IDEAL Set Screw Wire Connectors Model 1 or 2 #10 2 or 4 #12 2 or 6 #14 4 or 6 #16 2 or 6 #18 22 1 #10 str.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 16 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise. IDEAL Crimp Connectors Model 2 #10 str 2 or 4 #12 3 or 6 #14 2 #14 str. 3 or 7 #16 5 or 10 #18 1 #14 sol w/1 #14 str. 1 #10 sol w/1 #10 str.
UNDERWRITER’S LABORATORIES LISTED WIRE COMBINATIONS UL File No. E5238 Page 17 Combinations listed on this page are CU/CU Wire only. (Do not use on aluminum wire.) For use on solid and/or stranded wire combinations unless noted otherwise.