Datasheet

12
HS6E Subminiture Interlock Switches with Solenoid
Small interlock switch with five poles and solenoid.
Ideal for applications in tight spaces.
Compact body: 75 × 15 × 75 mm
15-mm-wide, thinnest solenoid interlock switch in the world.
Reversible mounting and angled cable allow four actuator insertion
directions.
Energy saving. 24V DC, 110 mA (solenoid: 100 mA, LED: 10 mA).
Can be driven directly by a controller.
Manual unlocking possible on three sides.
LED indicator shows solenoid operation
Spring Lock
Automatically locks the actuator without power applied to the sole-
noid.
After the machine stops, unlocking is completed by the solenoid.
Manual unlocking is possible on three sides in the event of power
fail ure or maintenance.
Solenoid Lock
The actuator is locked when energized.
The actuator is unlocked when de-energized.
•Flexible locking function can be achieved, for an application where
locking is not required and sudden stopping of a machine must be
pre vented.
Horizontal/Vertical Angle Adjustable Actuators
Straight Actuator
(SUS304)
Right-angle Actuator (SUS304)
Ratings
Contact Ratings
Rated Insulation Voltage (Ui) (Note 1)
300V (door monitor contact)
150V (lock monitor contact)
30V (between LED or solenoid and
ground)
Rated Thermal Current (Ith)
Operating temperature –25 to 35°C
2.5A (up to 2 circuits)
1.0A (3 or more circuits)
Operating temperature 35 to 50°C
1.0A (1 circuit)
0.5A (2 or more circuits)
Rated Voltage (Ue) 30V 125V 250V
Rated Current (Ie) *
Main & Lock
Monitor Circuits
AC
Resistive load (AC-12) 2A
Inductive Load (AC-15) 1A
DC
Resistive load (DC-12) 2A 0.4A
Inductive Load (DC-13) 1A 0.22A
Door Monitor
Circuit
AC
Resistive load (AC-12) 2.5A 1.5A
Inductive Load (AC-15) 1.5A 0.75A
DC
Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive Load (DC-13) 2.3A 0.55A 0.27A
•Minimum applicable load (reference value): 3V AC/DC, 5 mA
Approved ratings
TÜV UL/c-UL CCC
Door
Monitor
Contact
AC-15 240V/0.75A
DC-13 250V/0.27A
DC-13 30V/2.3A
240V AC/0.75A Pilot Duty
250V DC/0.27A Pilot Duty
C300
Q300
AC-15 240V/0.75A
DC-13 30V/2.3A
Lock
Monitor
Contact
AC-15 125V/1A
DC-13 125V/0.22A
DC-13 30V/1A
125V AC/1A Pilot Duty
125V DC/0.22A Pilot Duty
DC-13 30V/1A Pilot Duty
AC-15 125V/1A
DC-13 30V/1A
Solenoid/Indicator
Locking Mechanism Spring Lock Solenoid Lock
Rated Voltage 24V DC (100% duty cycle)
Rated Current
110 mA (solenoid 100 mA, LED 10 mA)
(initial value)
Solenoid
Coil Resistance 240Ω (at 20°C)
Pickup Voltage Rated voltage × 85% maximum (at 20°C)
Dropout Voltage Rated voltage × 10% minimum (at 20°C)
Maximum Continuous
Applicable Voltage
Rated voltage × 110%
Maximum Continuous
Applicable Time
Continuous
Insulation Class Class F
Indicator
Light Source LED
Illumination Color Green
Specifications
Applicable Standards
ISO14119
IEC60947-5-1
EN60947-5-1 (TÜV approved)
EN1088 (TÜV approved)
GS-ET-19 (TÜV approved)
UL508 (c-UL listed)
CSA C22.2 No. 14 (c-UL listed)
IEC 60204-1/EN 60204-1 (applicable standards for use)
Operating
Temperature
–25 to +50°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree 3
Impulse Withstand
Voltage
Main & lock monitor circuits: 1.5 KV
Door monitor circuit: 2.5 kV
Between solenoid/LED and ground: 0.5 kV
Insulation Resistance
(500V DC megger)
Between live and dead metal parts: 100 MΩ minimum
Between terminals of different poles: 100 MΩ minimum
Contact Resistance
300 mΩ maximum (initial value, 1m cable)
500 mΩ maximum (initial value, 3m cable)
700 mΩ maximum (initial value, 5m cable)
Electric Shock
Protection
Class II (IEC 61140)
Degree of Protection IP67 (IEC 60529)
Shock Resistance
Operating extremes: 100 m/s
2
(10G)
Damage limits: 1000 m/s
2
(100G)
Vibration Resistance
Operating extremes: 10 to 55 Hz, amplitude 0.35 mm
Damage limits: 30 Hz, amplitude 1.5 mm
Actuator Operating
Speed
0.05 to 1.0 m/s
Direct Opening Travel
8.0 mm minimum
Direct Opening Force
60N minimum
Actuator Retention
Force
500N minimum (GS-ET-19)
Operating Frequency 900 operations/h
Mechanical Durability 1,000,000 operations minimum (GS-ET-19)
Electrical Durability
100,000 operations minimum (rated load)
1,000,000 operations minimum (24V AC/DC, 100 mA)
(operating frequency 900 operations/h)
Conditional
Short-circuit Current
50A (250V)
(Use 250V/10A fast-blow fuse for short-circuit protection.)
Cable
UL2464, No. 22 AWG
(12-core: 0.3 mm
2
or equivalent/core)
Cable Diameter ø7.6 mm
Weight (approx.)
220g (1m cable)
410g (3m cable)
600g (5m cable)

Summary of content (13 pages)