8
HS6B Subminiature Interlock Switches
World-class compactness with three poles of contacts.
•World’s smallest switch: 30 × 15 × 78 mm
•Dual contacts and monitor contacts achieve the highest safety cat-
egory (ISO 13849-1, EN 954-1)
•Two actuator entry slots provide flexibility for installation options.
•Integral cable design minimizes wiring, preventing wiring mis takes.
•Can be mounted in two directions.
•Degree of protection (contacts): IP67 (IEC 60529)
Housing allows drainage.
•NC contacts are direct opening action (IEC/EN 60947-5-1).
•Proprietary actuators prevent unauthorized opening of the con tacts
(ISO14119, EN1088).
Vertical/horizontal Angle
Adjustable Actuator (for hinged
door)
Right-angle Actuator
(SUS304)
Straight Actuator
(SUS304)
Specifications
Applicable Standards
ISO14119
EN1088
IEC60947-5-1
EN60947-5-1 (TÜV approved)
GS-ET-15 (TÜVapproved)
UL508 (UL-listed)
CSA C22.2 No. 14 (c-UL-listed)
GB14048.5 (CCC approved)
IEC 60204-1/ EN 60204-1
(applicable standards for use)
Applicable Directive
2006/95/EC (Low Voltage Directive)
2006/42/EC (Machinery Directive)
Operating
Temperature
–25 to +70°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree 3
Impulse Withstand
Voltage
4 kV
Insulation Resistance
(500V DC megger)
Between live and dead metal parts:
100 MΩminimum
Between terminals of different poles:
100 MΩminimum
Contact Resistance
300 mΩ maximum (initial value, 1m cable)
500 mΩ maximum (initial value, 3m cable)
700 mΩ maximum (initial value, 5m cable)
Electric Shock
Protection Class
Class II (IEC 61140)
Degree of Protection IP67 (IEC 60529)
Shock Resistance
Operating extremes: 300 m/s
2
(30G)
Damage limits: 1000 m/s
2
(100G)
Vibration Resistance
Operating extremes:
5 to 55 Hz, amplitude 0.5 mm
Damage limits:
30 Hz, amplitude 1.5 mm
Actuator Operating
Speed
0.05 to 1.0 m/s
Direct Opening Travel 8 mm minimum
Direct Opening Force 60N minimum
Operating Frequency 1200 operations/h
Mechanical Durability 1,000,000 operations minimum (GS-ET-15)
Electrical Durability
100,000 operations minimum
(operating frequency 1200 operations/h,
load AC-12 250V/1.5A, DC-12 250V/0.2A)
1,000,000 operations minimum
(operating frequency 1200 operations/h,load 24V
AC/DC, 100mA)
Conditional
Short-circuit Current
50A (250V) (Use 250V/10A fast-blow fuse for
short- circuit protection.)
Housing Color Black
Cable UL2464 No. 20 AWG (6-core)
Weight (approx.)
120g (HS6B-***01, cable length 1m)
270g (HS6B-***03, cable length 3m)
420g (HS6B-***05, cable length 5m)
Interlock Switch
Contact Configuration Cable Length
Part No.
(Package quantity: 1)
1NC-1NO
1m
HS6B-11B01
3m
HS6B-11B03
5m
HS6B-11B05
2NC
1m
HS6B-02B01
3m
HS6B-02B03
5m
HS6B-02B05
2NC-1NO
1m
HS6B-12B01
3m
HS6B-12B03
5m
HS6B-12B05
3NC
1m
HS6B-03B01
3m
HS6B-03B03
5m
HS6B-03B05
•Contact configuration shows the status when the actuator is inserted.
Actuators
Description
Part No.
(Package quantity: 1)
Straight Actuator
HS9Z-A61
Right-angle Actuator
HS9Z-A62
Horizontal/vertical Angle Adjustable
Actuator (for hinged doors) (Note)
HS9Z-A65
HS9Z-A66
Note: Select an actuator that moves in the direction required by the
hinged door and interlock switch (see pages 9 and 10).
Contact Ratings
Rated Insulation Voltage (Ui) 300V
Rated Current (Ith) 2.5A
Rated Voltage (Ue) *
30V 125V 250V
Rated
Current
(Ie) *
AC
Resistive load (AC-12)
2.5A 1.5A
Inductive Load (AC-15) 1.5A 0.75A
DC
Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive Load (DC-13) 2.3A 0.55A 0.27A
•Minimum applicable load (reference): 3V AC/DC, 5mA
Approved ratings
TÜV
AC-15 240V/0.75A
DC-13 250V/0.27A
DC-13 30V/2.3A
UL/c-UL
240V AC/0.75A Pilot Duty
250V DC/0.27A Pilot Duty
C300
Q300
CCC
AC-15 240V/0.75A
DC-13 30V/2.3A
3433
12
Zb
11
3231
11
Zb
12
3231
12
22
Zb
11
21
31
21
11
Zb
32
22
12

Summary of content (4 pages)