Datasheet
LF2B LED Illumination Units
(22.5)
Recommended mounting centers: B
A
L
Cable: 1000
ø5.5
Mounting Bracket
(supplied)
45
31
Flat Screw M4
(supplied)
6
R2.1
Mounting Bracket (optional)
31
40
C
D
(7)
(7)
Cable
AWG 18
Cover
End Cover
Blue: N
Brown: L
(DC: +)
(DC: –)
29
40
Cable
Gland
M4×P0.7
Screw Hole
Anti-projection
Hole
(Either one
of the two)
Or ø4.2
Hole
8.5
ø2.1
B
A
20
28
39
ø4.2
1.7
20
D
M4 Screw Hole or ø4.2 Hole
(22.5)
Recommended mounting centers: B
A
L
Cable: 1000
ø5.5
Mounting Bracket
(supplied)
45
31
Flat Screw M4
(supplied)
6
R2.1
Mounting Bracket (optional)
31
40
C
D
(7)
(7)
Cable
AWG 18
Cover
End Cover
Blue: N
Brown: L
(DC: +)
(DC: –)
29
40
Cable
Gland
M4×P0.7
Screw Hole
Anti-projection
Hole
(Either one
of the two)
Or ø4.2
Hole
8.5
ø2.1
B
A
20
28
39
ø4.2
1.7
20
D
M4 Screw Hole or ø4.2 Hole
Mounting Hole Layout
Recommended
Mounting Hole
Layout
Recommended
Mounting Hole
Layout
(22.5)
Recommended mounting centers: B
A
L
Cable: 1000
ø5.5
Mounting Bracket
(supplied)
45
31
Flat Screw M4
(supplied)
6
R2.1
Mounting Bracket (optional)
31
40
C
D
(7)
(7)
Cable
AWG 18
Cover
End Cover
Blue: N
Brown: L
(DC: +)
(DC: –)
29
40
Cable
Gland
M4×P0.7
Screw Hole
Anti-projection
Hole
(Either one
of the two)
Or ø4.2
Hole
8.5
ø2.1
B
A
20
28
39
ø4.2
1.7
20
D
M4 Screw Hole or ø4.2 Hole
With mounting bracket LF9Z-1SB21 (U-shaped brackets supplied with LED) Mounting bracket LF9Z-1SB21
Mounting bracket LF9Z-1SB22
With mounting bracket LF9Z-1SB22
(L-shaped bracket purchased separately from LED)
Part No. A B C D
Required No. of
Mounting Bracket
LF9Z-1SB21 LF9Z-1SB22
LF2B-B∗P-∗THWW2-1M 165 – 236 224
2
2
LF2B-C∗P-∗THWW2-1M 285 – 356 344
LF2B-D∗P-∗THWW2-1M 535 – 606 594
LF2B-E∗P-∗THWW2-1M 785 393 856 844 3
LF2B-F∗P-∗THWW2-1M
1,035
345
1,106 1,094
4
•LED modules may vary in illumination colors and illuminance.
•Before designing equipment and powering up units, confirm the
specifications described in the instruction sheet.
•Apply voltage within the rated values, otherwise the LED elements
may be damaged.
•The LF2B is vulnerable to static electricity. Take sufficient mea-
sures for protection against static electricity and voltage surges.
•Make sure that the unit is not dropped during transportation,
installation, and operation, otherwise damage may result.
•Do not pull or push the cable, otherwise damage may result.
Allow sufficient slack to the cable while wiring.
•Do not apply excessive force. Do not leave a damaged unit unat-
tended or use a damaged unit.
•Do not use or store in a location subjected to vibration and shock.
•Do not use in the following locations:
∗ Exposure to direct sunlight, near heaters, high temperatures
∗ Subject to oil, metal powder, chemicals, and corrosive gases
(Plastic illumination surface: avoid iron powder and oil)
∗ Places with high humidity such as basements and green-
houses
∗ Cold storage warehouses (make sure that no freezing occurs)
•Do not loosen screws, otherwise the protection characteristics will
be impaired.
•To clean the cover, use a soft cloth with water or neutral deter-
gent. Do not use solvents such as thinners, benzene, or alkaline,
otherwise discoloration, deterioration, or decrease in strength may
occur.
•The edge of the cable sheath is not waterproof construction. Wa-
ter may invade the LF2B in a capillary action when water splashes
directly onto the cable sheath.
4.2
17.6
23.6
2-R2.1
•Do not disassemble, repair, or modify LF2B. Otherwise electric
shock, fire, or malfunction may occur.
•Turn off power before wiring. To prevent electric shock or damage,
ensure that the wiring is correct.
•Do not stare directly into the LF2B while it is lit, and do not proj-
ect the light towards other people, otherwise their eyes may be
injured.
•The LF2B is general-purpose industrial electric device. Do not
use with electronic equipment which may cause harm or injury to
anyone or threaten life in case a malfunction or failure occurs.
Specicationsandotherdescriptionsinthiscatalogaresubjecttochangewithoutnotice.
Cat.No.EP1511-2MARCH2016PDF
IDECELEKTROTECHNIKGmbH
Tel:+49-40-253054-0,Fax:+49-40-253054-24
E-mail:service@eu.idec.com
IDEC(SHANGHAI)CORPORATION
Tel:+86-21-6135-1515
Fax:+86-21-6135-6225/+86-21-6135-6226
E-mail:idec@cn.idec.com
IDEC(BEIJING)CORPORATION
Tel:+86-10-6581-6131,Fax:+86-10-6581-5119
IDEC(SHENZHEN)CORPORATION
Tel:+86-755-8356-2977,Fax:+86-755-8356-2944
IDECIZUMI(H.K.)CO.,LTD.
Tel:+852-2803-8989,Fax:+852-2565-0171
E-mail:info@hk.idec.com
IDECTAIWANCORPORATION
Tel:+886-2-2698-3929,Fax:+886-2-2698-3931
E-mail:service@tw.idec.com
IDECIZUMIASIAPTE.LTD.
Tel:+65-6746-1155,Fax:+65-6844-5995
E-mail:info@sg.idec.com
IDECASIA(THAILAND)CO.,LTD.
Tel:+662-392-9765,Fax:+662-392-9768
E-mail:sales@th.idec.com
www
.idec.com
IDECCORPORATION(USA)
Tel:+1-408-747-0550/(800)262-IDEC(4332)
Fax:+1-408-744-9055/(800)635-6246
E-mail:opencontact@idec.com
IDECCANADALIMITED
Tel:+1-905-890-8561,
TollFree:(888)317-IDEC(4332)
Fax:+1-905-890-8562
E-mail:sales@ca.idec.com
IDECAUSTRALIAPTY.LTD.
Tel:+61-3-8523-5900,TollFree:1800-68-4332
Fax:+61-3-8523-5999
E-mail:sales@au.idec.com
6-64, Nishi-Miyahara 2-Chome, Yodogawa-ku, Osaka 532-0004, Japan
Tel:+81-6-6398-2527,Fax:+81-6-6398-2547
E-mail: marketing@idec.co.jp
Safety Precautions
Operating Instructions