User manual

Problem Possible cause Solution
Water flows on the rear
plate of the refrigerator.
During the automatic defrost-
ing process, frost defrosts on
the rear plate.
This is correct.
Water flows into the re-
frigerator.
The water outlet is clogged. Clean the water outlet.
Products prevent that water
flows into the water collector.
Make sure that products do not
touch the rear plate.
Water flows on the
ground.
There is too much water in the
air deflector.
Clean the air deflector.
The temperature in the
appliance is too low/
high.
The temperature regulator is
not set correctly.
Set a higher/lower tempera-
ture.
If your appliance is still not working properly
after making the above checks, contact the
After Sales Centre. You can find the list at the
end of this manual.
Replacing the lamp
Caution! Disconnect the plug from the
mains socket.
1. Remove the
screw from the
lamp cover.
2. Remove the
lamp cover.
3. Replace the
lamp with one
of the same
power and
specifically de-
signed for household appliances. (the
maximum power is shown on the lamp
cover).
4. Install the lamp cover.
5. Tighten the screw to the lamp cover.
6. Connect the plug to the mains socket.
7. Open the door. Make sure that the light
comes on.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to the
assembly instructions.
3. If necessary, replace the defective door
gaskets. Contact the After Sales Service.
Technical data
Dimensions
Height 815 mm
Width 596 mm
Depth 550 mm
Net Volume 136 Litre
Defrost System auto
Energy Consumption 0,321 kWh/24h
Noise Level 35 dB (A)
Energy Class A+