User's Manual

70-M USER’S MANUAL
70-M V1.1 (05/07) 120009-0D.pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso. 11
70-M V1.1 (05/07) 120009-0D.pdf IKUSI reserves the right to modify this information without prior notification.
5.- RECEIVERS
5.1.- TYPES OF RECEIVERS (CONNECTIONS BLOCK DIAGRAMS)
R70MP10: PWM OUTPUT RECEIVER (10 OUTPUTS).
R70MR11: RECEIVER WITH OUTPUT RELAYS (11 OUTPUTS).
R70MR06: RECEIVER WITH OUTPUT RELAYS (6 OUTPUTS).
The voltage DC of the power supply (from 9v to 35v
DC, is conducted to the common wiring of the ten
output switches (OUT1 until OUT10), through a
SAFETY switch which guarantees the output
disconnection in case of breakdown of some of the
outputs. The “RELAY” switches between two fixed
positions NO (normally opened) and NC (normally
closed).
LIB-ID: pushbutton to release the ID from the receiver.
Press < 2 seconds without EP70 module connected.
EP70: On board plug in connector to connect an
external EP70
(
External EEPROM
)
.
R70MR11 and 70MR06 models only:
- Remember to connect the ground cable.
- Only use fireproof cables for connections.
- Select the appropriate voltage on the receiver, (230, 115 or 48 Vac). R70MR11 and R70MR06
models.
RL-1: Power supply plug in terminals (24,48,115
or 230 V AC). Please note –see table- the right
fuse values depending on the input voltage.
RL-2: Plug in identified connection terminals, 1st
and 2nd speed (K1….K11) and START relay.
RL-3: Plug in terminal for connecting the STOP
relay (NO Cat.3 EN-954-1)
LIB-ID: pushbutton to release the ID from the
receiver. Press < 2 seconds without EP70
module connected.
EP70: On board plug in connector to connect an
external EP70
(
External EEPROM
)
.
RL-1: Power supply plug in terminals (24,48,115 or 230 V
AC). Please note –see table- the right fuse values
depending on the input voltage.
RL-2: Plug in identified connection terminals, 1st and 2nd
speed, HOISTING; TROLLEY TRAVELLING; SAFETY;
START: STOP (Cat.3 EN-954)
LIB-ID: pushbutton to release the ID from the receiver.
Press < 2 seconds without EP70 module connected.
EP70: On board plug in connector to connect an external
EP70 (External EEPROM).