User's Manual

70-M USER’S MANUAL
70-M V1.1 (05/07) 120009-0D.pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso. 24
70-M V1.1 (05/07) 120009-0D.pdf IKUSI reserves the right to modify this information without prior notification.
6.8.2.- PROGRAMMABLE PARAMETERS (TELE-ALIGNED):
PROGRAMMABLE VALUES (TELE-ALIGNED)
Parameter Default value Range (programmable values)
START (KEY SOFTWARE)
T70MG10: NO
T70MH3/T70MH3D/T70MH2:
See User’s Manual
SEARCH MODE OFF ON, OFF. (SEARCH MODE)
TOUT LATENCY 4min 1 to 6min; steps of 1 min, and infinite (“INF” value) minutes. (Time to LATENCY state).
TOUT OFF 15min
10 to 20min step of 1 min, and infinite (“INF” value). (Time from LATENCY state to “Stand-by” state or “low
consumption” mode).
TSTOP 2sec 1 to 10sec.: steps of 0,1sec. (Passive STOP time)
OUTMODE MOMENTARY MOMENTARY or LATCHING (OUTPUTS: OPERATING MODES)
SOFTSTART ON ON or OFF (Enable or Disable soft start)
SOFTSTOP ON ON or OFF (Enable or Disable soft stop)
ACCELRAMP 0,1sec
0,0sec, 0,1sec, 0,2sec, 0,3sec, 0,4sec, 0,5sec, 0,6sec, 0,8sec, 1,0sec, 1,2sec, 1,5sec, 1,7sec, 2.0sec, 2,5sec 3,5sec, 5.0sec
(Ramp acceleration adjustment for each output)
DECELRAMP 0,1sec
0,0sec, 0,1sec, 0,2sec, 0,3sec, 0,4sec, 0,5sec, 0,6sec, 0,8sec, 1,0sec, 1,2sec, 1,5sec, 1,7sec, 2.0sec, 2,5sec 3,5sec, 5.0sec
(Ramp deceleration adjustment for each output)
PWM FREQ 300Hz 30Hz to 300Hz; Step = 10Hz. (R70MP10: PWM output frequency adjustment. Independent for each output).