Risk of Unsafe Operation. Unit cycles automatically when



compressor to cool.
  
Low pressure or
not enough air
or Compressor
does not stop
Tank drain valve is open Close drain valve
Fittings leak Check fittings with soapy water.
Tighten or reseal leaking fittings.
DONOTOVERTIGHTEN.
Restricted air intake Clean or replace intake filter element.
Prolonged excessive
use of air
Decrease amount of air used.
Compressor not
large enough
Check air requirement of accessory.
If it is higher than CFM and
pressure supplied by compressor,
you need a larger compressor.
Most accessories are rated at 25% of
actual CFM while running continuously.
Hole in air hose Check and replace if necessary.
Tank leaks
Immediately replace
tank. DO NOT attempt to repair.
Blownseals Replace seals.
Valveleaks Replace seals.
Leaking or worn piston Replace piston.
Air leaks from
regulator, or
regulator does
not regulate
pressure
Dirty or damaged
regulator internal parts.
Replace regulator or internal parts.