Use and Care Manual

2 - ENG
200-2903
SPECIFICATION CHART ......................................................... 2
SAFETY GUIDELINES .......................................................... 2-4
GLOSSARY OF TERMS .......................................................... 4
OVERVIEW ........................................................................... 4-5
ASSEMBLY .............................................................................. 5
TYPICAL INSTALLATION ........................................................ 6
COMPRESSOR CONTROLS ................................................... 7
ELECTRICAL POWER REQUIREMENTS ............................... 7
OPERATING INSTRUCTIONS ................................................ 8
MAINTENANCE .................................................................. 9-11
SERVICE INTERVAL ............................................................. 11
TROUBLESHOOTING CHART .............................................. 12
TABLEOFCONTENTS
SAFETYGUIDELINES
IMPORTANTSAFETYINSTRUCTIONS
The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize
this information, we use the following symbols. Please read the manual and pay attention to these sections.
–APOTENTIALHAZARDTHATWILLCAUSESERIOUSINJURYORLOSSOFLIFE.
–APOTENTIALHAZARDTHATCOULDCAUSESERIOUSINJURYORLOSSOFLIFE.
–APOTENTIALHAZARDTHATMAYCAUSEMODERATEINJURYORDAMAGETO
EQUIPMENT.
WARNING:
DANGER:
CAUTION:
WARNING:
SPECIFICATIONCHART
MODELNO. IV5008055 IV5018055 IV5038055
RUNNINGH.P.
5.2 5.2 5.2
TANKCAPACITYGALLONS
80 (302,8 Liters) 80 (302,8 Liters) 80 (302,8 Liters)
VOLTAGE
230 230 230
AMPS
22 22 14.3
PHASE
1 1 3
APPROXIMATECUT-INPRESSURE
145 (10 bar) 145 (10 bar) 145 (10 bar)
APPROXIMATECUT-OUTPRESSURE
175 (12 bar) 175 (12,1 bar) 175 (12,1 bar)
RISKOFFIREOREXPLOSION. Never spray flammable liquids in a confined area. It is normal for the motor and pressure switch
to produce sparks while operating. If sparks come into contact with vapors from gasoline or other
solvents, they may ignite, causing fire or explosion. Always operate the compressor in a well–
ventilated area. Do not smoke while spraying. Do not spray where sparks or flame are present.
Keep compressor as far from spray area as possible. Store flammable materials in a secure
location away from compressor. Equip the area of operation with a fire extinguisher.
RISKOFBURSTING. Do not weld, drill or modify the air tank of this compressor. Welding or modifications on the air
compressor tank can severely impair tank strength and cause an extremely hazardous condition.
Welding or modifying the tank in any manner will void the warranty. If tank develops a leak, replace
it immediately with a new tank or replace the entire compressor.
RISKOFELECTRICALSHOCK. Never use an electric air compressor outdoors when it is raining or on a wet surface, as it may
cause an electric shock. Failure to provide adequate grounding to this product could result in
serious injury or death from electrocution. Make certain that the electrical circuit to which the
compressor is connected provides proper electrical grounding, correct voltage and adequate fuse
protection.