Data Sheet

Page
23
10. Hardware Serial RS-232 & RS-485 Configuration
Hardware Serial RS-485
Switch configuration:
In order to enable the Hardware Serial RS-485 the total configuration of the Ardbox Analog HF
will be:
LEFT ZONE
SWITCH
MODE
DE-RS485
ON
D10/A0.2-Q0.2
OFF
RE-RS485
ON
D11/A0.1-Q0.1
OFF
SDA-D2/I0.0
-
SCL-D3/Q0.6
-
TOP ZONE
SWITCH
MODE
I0.3
OFF
RS485 HS
ON
I0.2
OFF
RS485 HS
ON