Data Sheet

Page
24
Jumper configuration:
Having configured Ardbox Analog HF as it is shown above, these are the features that are
available:
o Available communication protocols:
Hardware Serial RS-485.
I2C *If I2C is active I0.0 & Q0.6 are disabled
SPI
TTL
USB
o Inputs: 8 out of 10 inputs, I0.0, I0.1 and 10.4 to I0.9. If using I2C I0.0 is also disabled
o Digital Outputs: All 10 outputs. If using I2C Q0.6 is disabled.
o Analog Outputs: From A0.0 to A0.6. If using I2C A0.6 is disabled
Hardware Serial RS-232
In order to enable the Hardware Serial RS-232 the total configuration of the Ardbox Relay HF
will be:
Switch configuration:
JUMPER ZONE 1
LEFT
RIGHT
RS-485
RS-485
D0
D1
-
-
JUMPER ZONE 2
LEFT
RIGHT
I0.2
I0.3
D4
D8
-
-
LEFT ZONE
SWITCH
MODE
DE-RS485
OFF
D10/A0.2-Q0.2
ON
RE-RS485
OFF
D11/A0.1-Q0.1
ON
SDA-D2/I0.0
-
SCL-D3/Q0.6
-
TOP ZONE
SWITCH
MODE
I0.3
OFF
RS232 HS
ON
I0.2
OFF
RS232 HS
ON
Note: The switches of the left
zone of the RS-485 dont
interfere in the RS-232 HS, the
thing is that as pins 0 & 1 are
reserved for the RS-232, the
RS-485 is totally disabled. As it
is disabled, there is no point on
configuring these switches as
RS-485 mode