MOUNTING INSTRUCTIONS
Heater must be installed with the Quartz horizontally level. For maximum tube life, use a carpenter’s level tool to
nd the optimum level position for the heater’s body. Always maintain the minimum clearances from the heater
body to any combustible materials.
6"
[15.2 CM]
3" [7.6 CM]
8-3/16"
[20.2 CM]
9-3/8" [23.8 CM]
5-3/8"
[13.6 CM]
SWIVEL MOUNTING
BRACKETS [CEILING
OR WALL MOUNT]
LENGTH WILL VARY
DEPENDING ON
MODEL
INSULATED HOUSING
These models may be chain or bracket mounted to any ceiling or horizontal surface. Installation must be such
that 18" [45.7 cm] minimum clearance is maintained around the heater on all 4 sides and 36" [91.4 cm] directly in
front. A minimum of 6" [15.24 cm] of clearance provided by mounting brackets is required behind the plane of the
face. Heater can be hung using chains or custom brackets. Heater must be level, but can be rotated around its
horizontal axis.