IS THERE VOLTAGE FROM IGNITION
CONTROL TO COMBINATION GAS
VALVE?
CHECK ELECTRICAL WIRES FROM IGNITION
CONTROL TO COMBINATION GAS VALVE
CHECK IGNITION CONTROL, REPLACE IF
NECESSARY
NO
IS GAS COMING THROUGH
ORIFICE ON THE HEATER?
YES
ENSURE ALL GAS VALVES ARE OPEN
NO
YES
DOES THE IGNITION CONTROL
TERMINATE THE SPARKING
PROCESS AFTER THE HEATER IS
OPERATING?
CHECK SPARK IGNITER FOR CRACKS,
REPLACE SPARK IGNITER IF NECESSARY
ENSURE THE SENSING WIRE IS SECURELY
CONNECTED TO THE SENSING PROBE
CLEAN THE SENSING PROBE ON THE SPARK
IGNITER
ENSURE THE FLAME SENSOR IS WITHIN 1/4"
ABOVE THE CERAMIC TILE
CHECK FLAME SIGNAL WITH METER, IF LOW
CHANGE SENSOR
REPLACE WITH NEW IGNITION CONTROL
UNIT IF OTHER CHECKS ARE OK
DOES HEATER SHUT DOWN
AFTER IGNITION CEASES?
CHECK FLAME SIGNAL USING A METER
INSTALLED IN SERIES WITH SENSOR CABLE,
CHECK (MICROAMPS) STRENGTH OF SIGNAL
FOR 1.5uA MINIMUM
YES
YES
NO
NO
STILL HAVING TROUBLE
OPERATING THE HEATER?
REPEAT THE ABOVE TROUBLE SHOOTING
PROCEDURES
IF THE PROBLEM PERSISTS, CONTACT YOUR
SCHWANK DISTRIBUTOR.
YES
NO
TROUBLESHOOTING
COMPLETE
IF SIGNAL IS LOW REPLACE SENSOR AND
WIRE