Datasheet

Functions INSYS Modem 336/56k 4.1 (UL)
5.8 Send Messages
Not for INSYS Modem LL.
Note: The sending time of an SMS from the sender to a recipient de-
pends on the pertinent provider of the service number. De-
pending on the degree of utilization and the time of day, an
SMS may be on the way for an extended period.
5.8.1 Transmission Configuration
The modem can not only send the alarm message to another
analogue modem, but also to a mobile phone as an SMS. Cur-
rently GSM900 and GSM1800, and SMS to fixed networks, fax
and e-mail.
The maximum text length is 160 characters.
Protocol settings – see table -
Transmission Protocol Data format Example
Data Connection AT*M0
SMS to Mobile PET 8N1
D1 or
E Network
AT*M1
SMS to Mobile UCP 7E1 AT*M2
SMS to Mobile PET 7E1 AT*M3
SMS to Mobile UCP 8N1 D2 network AT*M4
Fax AT*M5
AT*M<n>
30 July 06