Datasheet

S Registry INSYS Modem 336/56k 4.1 (UL)
9 S Registry
S registries may be read and written using the ATS<n> command. (See Chapter 8
AT Command Set”, command ATS<n>) Certain S registries may only be read; into
others only a particular range of values may be entered.
If the range of values is exceeded, the modem will report OK, although the value
was not accepted. We therefore recommend to immediately check modifications
by reading (ATS<n>?).
Note:
* These registries are stored in the user defaults with AT&W0 or AT&W1.
** The defaults can differ depending on the set country code.
9.1 Overview S Registry
Register Function Units Range Default
S0* Rings to auto answer rings 0-5 5
S1 Ring counter rings 0-255 0
S2* Escape character ASCII 0-255 43
S3 Return character ASCII 0-127 13
S4 Line feed character ASCII 0-127 10
S5 Backspace character ASCII 0-255 8
S6* Waiting time for dial tone s 3-7 3
S7* Waiting time for carrier signal s 0-100 50
S8* Dialing pause s 1-7 2
S9* Reaction time on carrier signal 0.1 s 1-255 6
S10* Time between lost carrier signal and hang-up 0.1 s 14-254 14
S12* ESC prompt delay 0.02 s
0-255 50
S13* Number of dialing attempts for alarm 1-12 3
S14* General settings 146
S15* Data Transmit Controller DTC 1s 0-255 0
S17* Remote initial character 0-127 42
S21* Settings for V24 52
S22* Settings 117
S24* Time until changing to sleep mode s 0-255 0
S25 Time for DTR signal 0.01 s
0-255 5
S26 Time between RTS/CTS 0.01 s
0-255 1
S27* General settings - 137
S29 Time for modifiers „flash“ 10 ms
0-17 17
76 July 06