Datasheet

INSYS Modem 336/56k 4.1 (UL) S Registry
Register Function Units Range Default
S30 Time until hang-up for inactivity 10 s 0-255 0
S31* General settings - 192
S36* Resetting the error protocols - 135
S38 Time until forced hang-up s 0-255 20
S39* Flow control - 3
S40* General settings - 104
S41* General settings - 195
S46* Data compression - 138
S48* Settings for V42 negotiation phase - 7
S86 Error result code - read only
S91* Send level - 0-15 14
S95* Result code - 0
9.2 Description S Registry
Note: Registries marked with *) are stored in the user defaults with the command
AT&W.
S0* Number of ringing tones until automatically going off-hook
Number of rings until the modem goes off-hook
For S0=0 the modem will not go off-hook when a call comes in. The value of S0
can be between 0 and 5.
S1
Ringing tone counter
Counter for call ringing. S1 is read-only. S1 will be reset to zero, when the modem
answers a call.
S2*
Escape
Escape character which causes a switch from data mode to online command input
mode. Values larger than 127 will lead to the fact that no ESC character will be
recognized.
S3 Return
Carriage Return Character (CR).
July 06 77