Datasheet

INSYS Modem 336/56k 4.1 (UL) S Registry
S13* Number of dialing attempts to send the message
Bit Meaning
Bit 0 – 3 Number of dialing attempts Range of values: 1...12
Default value: 3
S13 determines the number of attempts to send the
message.
Note: The limitation to a maximum of 12 at-
tempts is necessary for approval pur-
poses (black listing).
Bit 4 - 7 Reserved
S14*
General settings
Bit Meaning
Bit 0 Reserved
Bit 1 Echo on inputs Command echo 0: Echo off
1: Echo on
Bit 2 Reserved
Bit 3 Result format
Result codes: 0: Message numbers (ATV0)
1: Message texts (ATV1)
Bit 4 Reserved
Bit 5 Tone/pulse dialing
Tone/pulse 0: Tone dialing (ATT)
1: Pulse dialing (ATP)
Bit 6 Reserved
Bit 7 Originate/answer Originate/answer 0: Answer mode
1: Originate mode
S15* DTC Time Settings
The idle connection control is a function integrated in the firmware which moni-
tors the data transmission in online mode. This function prevents the modem to
stay online for an unlimited amount of time, although no data is being transmit-
ted anymore.
In the registry S15, any time period between 1 and 255 seconds may be entered. If
S15 is set to 0, the idle connection control is switched off.
The timer will run immediately after the modem goes off-hook. As soon as the
timer has run out, a modem reset is performed (which will forcibly lead to the
hanging up of the modem).
S17* Initial character for remote configuration
In S17, the ASCII code of a character which is used to start the remote configura-
tion, is defined. Values >127 switch the remote configuration off completely. The
default setting in S17 is “42”, which equals the ASCII character “*”. This means
that the remote configuration is started with the Escape character sequence
<Pause> **** <Pause>.
Note: The number of characters in the Escape sequence is fixed to “4” characters).
July 06 79