Datasheet

S Registry INSYS Modem 336/56k 4.1 (UL)
S31* General settings
Bit Meaning
Bit 0 Reserved
Bit 1 Description
Connect message
0: 3-line message (\V0)
1: Expanded 1-line message (\V1)
Bit 2-3 Error correction
Messages
Messages:
0: Only PC baud rate
1: PC and phone baud rate (ATW1)
2: Only phone baud rate (ATW2)
Bit 4-7 Reserved
S36* Reset of error logs
Bit Meaning
Bit 0..2 determines what happens
if an attempt to establish a
V.42 LAP-M connection
fails. It is connected to the
registry S48.
0 Modem hangs up
1 Modem stays online and establishes a direct
mode connection.
2 Reserved
3 Modem stays online and establishes a direct
mode connection.
4 Modem attempts to establish a MNP connec-
tion. In case of failure it hangs up.
5 Modem attempts to establish a MNP connec-
tion. In case of failure a direct mode connection
is established.
6 Reserved
7 Modem attempts to establish a MNP connec-
tion. In case of failure a normal mode connec-
tion is established.
Bit 3.0.5 SMS type
0: normal fixed network modem (AT*M0)
1: D1 and E networks (AT*M1)
4: D2 network
(AT*M4)
5: Fax (AT*M5)
6: Fixed network SMS
(AT*M6)
Bit 6 Key abort
0: Key abort activated (AT%B0)
1: Key abort deactivated (AT%B1)
Bit 7 Call acceptance
1: Call answer not locked (AT*A1)
0: Call acceptance locked (AT*A0)
S38 Time period until forced hang up
Maximum time left for the buffers to empty their data, after a command to hang
up has been received. Only applies to error corrected connections.
82 July 06