Datasheet

S Registry INSYS Modem 336/56k 4.1 (UL)
S46* V.42bis Data Compression
S46=136 No data compression
S46=138 V.42bis data compression on
S48* V.42bis Connection setup protocol
S48=0 Only LAPM connection possible
S48=7 LAPM or MNP 4 connection
S48=128 Connection protocol as laid down in S36
S86
Error event code
When a connection fails (NO CARRIER), an event code is written into this registry.
S86=0 Normal disconnect, no error
S86=4 Carrier lost
S86=5 No establishing of an error-corrected (V.42) connection
S86=6 No extensions could be negotiated
S86=7 Remote terminal only supports synchronous modems
S86=8 No joint framing detected
S86=9 No protocol could be established
S86=10 Invalid answer when negotiating extensions
S86=11 No synchronous marks received from remote terminal
S86=12 Normal disconnection by remote terminal
S86=13 Remote terminal didn’t respond any more (ten attempts)
S86=14 Protocol error
S86=15 DTR drop
S86=16 Remote terminal demanded cleardown (GSTN cleardown)
S86=17 Inactivity timer expired
S86=18 Desired speed is not supported
S86=19 Long space disconnect
S86=20 Key abort (character was sent during connection setup)
S86=22 No connection setup possible
S86=23 Cleardown after 3 retrains
S86=25 Termination of the connection by the remote terminal or by a phone
connected in series
S86=26 Remote terminal hung up
84 July 06