90 MPCMM0001 Chassis Management Module Software Technical Product Specification
The Command Line Interface (CLI)
syncuserledstate
Gets/Sets whether the LED
state is synced between the
active and standby CMM.
Both "Yes" or "No" “Yes” or “No”
powersequence
Used to get/set the power
sequence order, Power
Sequencing Delay,
ShelfManagerControlledActiva
tion in the CDM.
Note: The power sequencing
delay is in tenths of a second
to delay before powering up
any other FRU after powering
this FRU. The value of the
power sequencing delay is
between 0 and 63. Shelf
Manager Controlled Activation
determines if the Shelf
Manager activates the FRU
residing at this location when it
reaches M2.
Both
It will be in INI format displayed on the
console as follows:
[Settings]
EntryCount=xxx
[Power Sequence 1]
Location=cmm1
FRUDeviceID=0
ShelfManagerControlledActivation=Ye
s
DelayBeforeNextPowerOn=0
[Power Sequence 2]
… …
[Power Sequence xxx]
Location=blade12
FRUDeviceID=0
ShelfManagerControlledActivation=N
o
DelayBeforeNextPowerOn=0
INI file with its path,
such as "-v /home/
PowerSeq.INI"
loginmessage
Used to customize the login
screen message by allowing
user to add the OEM name.
Both
The OEM string that is displayed at
the login screen
"OEMWelcomeMes
sage" where the
OEMWelcomeMess
age is the message
that will appear at
the login screen
Max length = 63
characters
cmdlineprompt
Used to customize the bash
prompt by allowing user to add
the OEM name.
Both
The OEM Name string to be
prepended to the $PS1 variable
"OEMName" where
the OEMName is
the string that will
appear at the
beginning of the
bash prompt.
Max length = 63
characters
FaultLEDColor
Get/Set the color of the fault/
health LED on the CMM
fronted FRUs (Filter Tray,
CDM) to be used when an
error is reported. Does not
affect CMM Health LED.
Both "amber" or "red" “amber” or “red”