17
Software
• BIOS, Drivers, and Operating System Installation
A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS
Setup Utility to determine the installed BIOS version. Compare this to the versions at:
http://www.intel.com/support/motherboards/server.
If new versions are available, update the BIOS on your server.
B. Configure your RAID Controller:
Use the instructions provided with the RAID controller.
C. Install your Operating System:
Use the instructions provided with the RAID controller
and with the operating system.
D. Install Operating System Drivers: With the operating system running, insert the
Intel
®
Server Deployment and Management DVD. If using a Microsoft Windows* operating system,
the Intel
®
Deployment Assistant will autorun and allow you to select the appropriate drivers to install.
On other operating systems, browse the DVD folders to locate and install the driver files.
Side 2
10
Locate the white 4-pin key header between Serial B port and Front
Panel USB port. Match the Key and connector orientation and press
down to install.
15
Install Add-in
Card (Optional)
See the documentation that came with your
server chassis for add-in card installation.
For the Intel
®
Server Chassis P4000 series,
see the Quick Installation User's Guide
accompanying the chassis.
14
Install TPM, RMM4 and
eUSB SSD (Optional)
See the Intel
®
Trusted Platform Module Hardware
User’s Guide for the TPM module installation.
See Intel
®
Remote Management Module 4 User
GUide for the RMM4 installation.
See the instructions come along with the eUSB SSD
device for eUSB SSD installation.
16
Finishing Up
CAUTION: See your chassis
documentation for AC power and
grounding requirements.
Network
USB 0
USB 1
USB 2
USB 3
NIC1
10/100/
1000 Mb
NIC2
10/100/
1000 Mb
NIC3
10/100/
1000 Mb
NIC4
10/100/
1000 Mb
Video
Serial A
Before installing your operating
system, you must finish your chassis
installation, make I/O connections and
plug in AC power.
See your chassis documentation for AC
power and grounding requirements.
Common Problems and Solutions
The system does not boot or show video at power-on.
Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power.
Only Intel
®
Xeon
®
Processor E5-2600 series
with 130 W and less Thermal Design Power (TDP) are supported on this server board.
Previous generation Intel
®
Xeon
®
processors are not supported.
Beep code 1-5-2-1 in a system means you do not have Intel
®
Xeon
®
Processor E5-2600 series
installed.
The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that indicates memory errors in early POST .
Remember, all DIMMs must be:
DDR3 800/1066/1333/1600 MHz UDIMM/RDIMM/LRDIMM.
From the same manufacturer.
Installed beginning with DIMM A1.
For a list of hardware components that have been tested with
this system, see:
http://www.intel.com/support/motherboards/server
Main Power
Connector Detail
C
Latch
Tab
CPU Power
Connector Detail
B
A
8
Make Server Board
Power Connections
Attach the CPU 1 power connector.
Attach the CPU 2 power connector.
CAUTION:
Note the location of the
latch on each power cable
connector and align it with the matching
tab on each server board socket.
A
B
Attach the main power connector.
C
IMPORTANT NOTE:
If you are using a
non-Intel server chassis with an ATX
power supply, see the documentation
that came with your chassis for
installation information.
11
Connect Hard Drives/Optical Drive to
Server Board
Connect SAS/SATA Data Cables to server board here.
NOTE:
* Ports 0-3 are eanbled as SATA ports by
default. Optional Intel
®
RAID C600
Upgrade Key is required to support SAS
feature on ports 0-3, or additional
SATA/SAS ports 4-7.
** 6Gb/s SATA port.
SAS/SATA 0*
SAS/SATA 1*
SAS/SATA 2*
SAS/SATA 3*
SAS/SATA 4*
SAS/SATA 5*
SAS/SATA 6*
SAS/SATA 7*
Server
Board
SATA 1**
SATA 4
SATA 5
SATA 3
SATA 2
SATA 0**
Server
Board
System Fan 7
Connector
Detail
System Fan 1-6
Connector
Detail
13
Chassis Fan Connections
For a non-Intel server chassis, see the documentation accompanying your chassis for specific chassis
fan connection requirements. Refer to the "Making Connections to the Server Board - Quick Reference"
section below.
C1DIMM C2 D1 D2
B2DIMM B1 A2 A1
E1DIMM E2 F1 F2
H2DIMM H1 G2 G1
Memory Configurations and Population Order:
Note: For additional memory configurations, see the
Techinical Product Specification for Intel
®
Server
Board S2600CP at:
http://www.intel.com/support/motherboards/server.
Memory sizing and configuration is supported only for
qualified DIMMs approved by Intel
®
.
Memory Type: Minimum of one 1 GB,
DDR3 800/1066/1333/1600 MHz
UDIMM/RDIMM/LRDIMM.
7
Install DIMM Memory Modules
DDR3 DIMM Memory Identification:
DIMM
notch and
socket
bump must
align as
shown.
Other
Memory
DDR3
This server board supports up to 16 DDR3 800/1066/1333/1600
UDIMM/RDIMM/LRDIMM.
CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures
to avoid possible damage to system components.
Install Optical
Drive and
Hard Drive(s)
See the documentation that came
with your server chassis for drive
installation.
9
Making Connections to the Server Board — Quick Reference
12
Attach Front Panel, Serial, and USB Connections
Note: For a non-Intel
chassis, see your
chassis documentation
for front panel features
and server board
connection requirements.
Internal
USB/Serial
Connector
Detail
Serial B
USB
Front Panel
USB
USB
Connector
Detail
Front Panel
Connector
Detail
Connect When
NIC3/NIC4
Ports Available
Install Intel® RAID C600
Upgrade Key (Optional)
Server Board
Power
Supply
CPU2 CPU1
Main Power
Front
Panel
SAS/SATA*
USB
E
B
A
D
C
F
G
FAN_2
FAN_1
H
I
Server Board
Power Supply
CPU2 CPU1
Main Power
Front
Panel
SAS/SATA*
SGPIO**
HSBP_I
2
C
USB
B
A
D
C
H
I
J
G
E
F
PMBus
FAN_3
FAN_4
FAN_5
FAN_2
FAN_1
K
L
M
N
O
STOR_UPG_KEY
= Make this connection
Intel
®
Server Chassis
P4000 series
A. CPU 1-2 Power Connector
B. Main Power Connector
C. Front Panel Header
Required Connections
Intel
®
Server Chassis
P4000 series
Optional Connections
D. System Fan 1 Header
E. System Fan 2 Header
F. System Fan 3 Header
G. System Fan 4 Header
H. System Fan 5 Header
I. System Fan 6 Header
J. System Fan 7 Header
K. CPU 1 Fan Header
L. CPU 2 Fan Header
M. Serial B
N. Storage Upgrade Key
O. USB (Front Panel)
P. IPMB
Q. SAS/SATA Connectors
R
1. SATA 6G R2. SATA 3G
S. RMM4 Lite
T. Chassis Intrusion
U. RMM4 NIC
V. HSBP_I
2
C
X. SATA SGPIO
Y. eUSB SSD
Z. TPM
AA. USB (Type A)
AB. LCP
AC. PMBus
W. SAS SGPIO
IMPORTANT Note:
Cables should be
tied for better airflow.
Use cable-ties as necessary.
Note: For a non-Intel Chassis, see your chassis documentation
for server board connection information.
Note: Not all optional connections are shown in this diagram.
Refer to your Server Board Service Guide, and your server
chassis documentation for additional connection information.
Cable Routing with Fixed Fans, Fixed HDDs, Fixed PSU Cable Routing with Hotswap Fans, backplane(s), redundant PSU(s)
Note: Make CPU
FAN connections
if necessary.
CPU1/CPU2 Power Cable
Server Board Main Power Cable
Backplane Power Cable
ODD Power Cable
Front Panel Cable, USB Cable
ODD Data Cable (Connect To White SATA 6G
Connectors On Server Board)
MiniSAS and SGPIO
PMBus Cable
HSBP_I2C Cable (From Server Board To First
Backplane)
HSBP_I2C Cable (From First Backplane To Second
Backplane when Second Backplane Available)
System FAN 1
System FAN 2
System FAN 3
System FAN 4
System FAN 5
A
B
C
D
E
F
G
H
I
J
K
L
L
N
O
A
B
C
D
E
ODD Data Cable (Connect To White
SATA 6G Connectors On Server Board)
Fixed HDD Data Cable
System FAN 1
System FAN 2
F
B
G
H
I
CPU1/CPU2 Power Cable
Server Board Main Power Cable
Fixed HDD Power Cable
ODD Power Cable
Front Panel Cable, USB Cable
Make the connections with fixed fans
Make the connections with hotswap fans, backplane(s), power supply(s)
Make the connection when applicable
C
Front Panel
SAS/SATA
Q
USB
O
IPMB
P
HSBP_I
2
C
V
CPU 1 Power
A
CPU 2 Power
A
Chassis Intrusion
T
RMM4 Lite
S
RMM4 NIC
U
SAS SGPIO
W
TPM
Z
Main Power
B
E
Sys Fan 2
D
Sys Fan 1
0
1
USB
AA
PMBus
LCP
AB
AC
Serial B
M
eUSB SSD
Y
CPU 1 Fan
K
CPU 2 Fan
L
G
Sys Fan 4
F
Sys Fan 3
I
Sys Fan 6
H
Sys Fan 5
Sys Fan 7
J
Storage Upgrade Key
N
DIMM E1
DIMM E2
DIMM F1
DIMM F2
DIMM H2
DIMM H1
DIMM G2
DIMM G1
DIMM B2
DIMM B1
DIMM A2
DIMM A1
DIMM C1
DIMM C2
DIMM D1
DIMM D2
SATA
R1
SATA
R2