Monthly Specification Update Intel® Server Board S2600CP Family Intel® Server Board S2600CO Family Intel® Server System P4000CP Family May, 2014 Intel® Server Boards & Systems
Intel® Server Boards & Systems Monthly Specification Update Revision History Date Modifications March, 2012 Initial release.
Monthly Specification Update Intel® Server Boards & Systems Contents Preface ....................................................................................................................................... 1 1. Nomenclature ......................................................................................................... 1 2. Product Scope........................................................................................................ 1 Summary Tables of Changes ......................
Intel® Server Boards & Systems Monthly Specification Update 25. Integrated BMC Web Console – Sensor Readings Page – Memory Throttling sensor status will stay “Critical” once triggered ...................................................................... 12 26. WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64bit OS ......... 12 27. System only reports the first occurrence of power redundancy loss ..................... 13 28. BMC will generate flood event log and send PEF continuously .......
Monthly Specification Update Intel® Server Boards & Systems
Intel® Server Boards & Systems Monthly Specification Update Preface This document is an update to the specifications contained in the Intel® Server Board S2600CP Family and Intel ® Server System P4000CP Family Technical Product Specification. It is intended for hardware system manufacturers and software developers of applications, operating systems, or tools. It will contain specification changes, specification clarifications, errata, and document changes. 1.
Monthly Specification Update S2600COE S2600CO4 2 Intel® Server Boards & Systems -20x 01.01.0001 01.01.1002 01.02.0003 01.03.0002 01.06.0001 01.08.0003 02.01.0002 02.02.0002 1.00 1.04 1.10 1.16 1.17 1.19 1.20 1.03 1.09 1.10 1.11 02.01.05.069 02.01.05.107 02.01.07.112 02.01.07.231 02.01.07.
Intel® Server Boards & Systems Monthly Specification Update Summary Tables of Changes The following tables provide an overview of known errata and known document changes that apply to the specified Intel Server Products. The tables use the following notations: Doc: Intel intends to update the appropriate documentation in a future revision. Fix: Intel intends to fix this erratum in the future. Fixed: This erratum has been previously fixed. No Fix: There are no plans to fix this erratum.
Monthly Specification Update Intel® Server Boards & Systems No. Plans Description of Errata 25. Fixed Integrated BMC Web Console – Sensor Readings Page – Memory Throttling sensor status will stay “Critical” once triggered 26. Fixed WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64bit OS 27. Fixed System only reports the first occurance of power redundancy loss 28. Fix BMC will generate event log until it full and send PEF continuely 29.
Intel® Server Boards & Systems Monthly Specification Update Errata 1. Linux* Operating Systems are not supported on RSTe mode Problem Intel® RSTe mode is not supported on Red Hat* Linux and SUSE* Linux. Implication User may not able to install Red Hat* Linux and SUSE* Linux on Intel® C600 Series Chipset based Server Boards under Intel® RSTe mode Status This issue may be fixed in future driver or BIOS releases. Workaround None. 2.
Monthly Specification Update 4. Intel® Server Boards & Systems HDD status LEDs do not function under specific configuration Problem If drives are connected through expander to SCU ports and configured under RSTe mode, the HDD status LEDs may not function properly. Implication HDD status LED may not show the HDD locate, HDD fault or RAID rebuild message. Status This issue is fixed in RSTe driver 3.2.0.1134 and later version. Workaround None. 5.
Intel® Server Boards & Systems Monthly Specification Update Implication User may see system hang with mentioned configuration. Status This issue is fixed in BIOS release R01.03.0002. Workaround None. 8. Microsoft Windows 2003* x86 installation failure under Pass-through mode of SCU controller Problem Microsoft Windows Server 2003* x86 installations on SCU RSTe pass-through mode fail. Implication User may not able to install Microsoft Windows Server 2003* x86 on mentined BIOS configuration.
Monthly Specification Update Intel® Server Boards & Systems Implication The SEL log may indicate that system has an occasional reset in a normal POST during DC cycle test (global reset). Status This issue was fixed in BMC 1.04. Workaround None. 11.
Intel® Server Boards & Systems Workaround 14. Monthly Specification Update Select another page in the Integrated BMC Web Console and then return to the Power Control Page. The Perform Action button will then be available. IPMI Get Chassis Status command returns incorrect Chassis Identify State. Problem When a Get Chassis Status command is issued, after the Chassis Identify LED has been forced on, the status of off (00b) is returned for Chassis Identify State (response data byte 4 – bits [5:4]).
Monthly Specification Update 17.
Intel® Server Boards & Systems Monthly Specification Update Status The issue is fixed with ESRT2 driver 15.00.0927.2012. Workaround None. 20. System may detect unrecognized sensors Problem Prior to updating the sytem with the FRU/SDR package, the system may detect unrecognized sensors. Implication The system may have additional System Event Log (SEL) for the unrecoginzed sensors being detected, system status LED may turn amber and system FAN may boost.
Monthly Specification Update Workaround 23. Intel® Server Boards & Systems None. System will boot from on-board video although install add-in video card Problem When try to boot from add-in video card, system can not boot up. Implication Bios video output policy by default was booting from onboard video although install the add-in video card. Status This issue was fixed in BIOS 01.02.0009 and changed video output to installed add-in video card by default.
Intel® Server Boards & Systems Monthly Specification Update Problem With Intel® LAN driver version 17.1, WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64bit OS. Implication You may not be able to wake system through onboard NIC port. Status This issue was fixed in a LAN driver 17.4 release. Workaround None. 27.
Monthly Specification Update 29. Intel® Server Boards & Systems System BIOS may report POST error code 0x146 with the Intel® Xeon Phi™ Coprocessor installed Problem System BIOS may report POST error code 0x146 “PCI out of resource error” when one or more Intel® Xeon Phi™ Coprocessors are installed with the BIOS default setting. Implication The Intel® Xeon Phi™ Coprocessor might not be recognized using the default BIOS setting as it requires more PCI space.
Intel® Server Boards & Systems Workaround 32. Monthly Specification Update None. Reported processor frequency is lower than expected when the BIOS setup option EIST is disabled and the system is also in idle mode. Problem When the system is in idle mode during OS runtime and EIST is disabled in BIOS setup, the reported processor speed may report a lower than expected frequency. Implication EIST may function incorrectly. Status This issue may be fixed in a future BIOS update. Workaround N/A.
Monthly Specification Update Documentation Changes N/A 16 Intel® Server Boards & Systems