Technical Advisory 1011

This Technical Advisory describes an issue which may or may not affect the customer’s product
Intel Technical Advisory TA-1011-01
5200 NE Elam Young Parkway
Hillsboro, OR 97124
June 14, 2012
Copyright © 2012 Intel Corporation. * Other names and brands may be claimed as the property of others.
I2C CABLE CONNECTION ISSUE WITH INTEL
®
SERVER SYSTEM P4208CP4MHGC
Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise,
to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such
products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of
Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent,
copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining
applications. Intel may make changes to specifications and product descriptions at any time, without notice. The Intel products
described herein may contain design defects or errors known as errata which may cause the product to deviate from published
specifications. Current characterized errata are available on request.
Products Affected
Intel
®
Server System P4208CP4MHGC, with the MM# and Serial Numbers, listed in the table below:
MM# From Serial Number To Serial Number
918995 FZUP2110413 FZUP2110413
918995 FZUP2130004 FZUP2130007
918995 FZUP2130121 FZUP2130121
918995 FZUP2130504 FZUP2130504
918995 FZUP2130506 FZUP2130597
918995 FZUP2130608 FZUP2130608
918995 FZUP2171697 FZUP2171699
918995 FZUP2171702 FZUP2171702
918995 FZUP2171704 FZUP2171706
918995 FZUP2171708 FZUP2171708
918995 FZUP2171710 FZUP2171714
918995 FZUP2171717 FZUP2171751
918995 FZUP2171753 FZUP2171803
Description
In the Intel
®
Server System P4208CP4MHGC with the above mentioned Serial Numbers, the I
2
C cable is connected to
the connector labeled “I2C_OUT” on the backplane (Figure 1). However, to install a second backplane in the system,
the I
2
C cable needs to be connected to the connector labeled “I2C_IN” on the original installed backplane (Figure 2).
When installing a second backplane in the Intel
®
Server System P4208CP4MHGC, the two backplanes need to be
cascaded with two I
2
C cables. The first I
2
C cable should connect to the “I2C_IN” connector on the first backplane, and
the second I
2
C cable should connect from the “I2C_OUT” connector on the first backplane to the “I2C_IN” connector on
the second backplane (Figure 3).