Monthly Specification Update Intel® Server Board S2600GZ/GL Intel® Server System R1000GZ/GL Product Family Intel® Server System R2000GZ/GL Product Family November, 2014 Intel® Server Boards and Systems
Monthly Specification Update Revision History Date Modifications March, 2012 Initial release. Added errata 1 through 14. April, 2012 Added documentation changes. May, 2012 Added errata 15, 16 and 17. June, 2012 Updated errata 2, 9, 10, 11 and 12, added errata 18. July, 2012 No update. August, 2012 Updated Product Scope, Table 2, added errata 19, 20, 21 and 22, updated errata 4 and 17. September, 2012 Updated errata 7 and 13. October, 2012 Added errata 23 and 24.
Monthly Specification Update Disclaimers The Monthly Specification Update Server System may contain design defects or errors known as errata that may cause the product to deviate from the published specifications. Current characterized errata are documented in this Specification Update. Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Monthly Specification Update Contents Preface .......................................................................................................................................1 Summary Tables of Changes ...................................................................................................2 Errata .........................................................................................................................................4 1.
Monthly Specification Update 26. The Intel® Xeon Phi™ Coprocessor PCI Express* Card Status Sensor may show "Unknown" 12 27. The Intel® Xeon Phi™ Coprocessor PCI Express* Card sensors numbering may not be consistent with riser slot numbering ............................................................................13 28. The Activity/Link LED of the Intel® I/O Expansion Modules may not be solid green13 29.
Monthly Specification Update
Monthly Specification Update Preface This document is an update to the specifications contained in the following documents: 1. Intel® Server Board S2600GZ/GL Technical Product Specification 2. Intel® Server System R1000GZ/GL Product Family Technical Product Specification 3. Intel® Server System R2000GZ/GL Product Family Technical Product Specification It is intended for hardware system manufacturers and software developers of applications, operating systems, or tools.
Monthly Specification Update Summary Tables of Changes The following tables provide an overview of known errata and known document changes that apply to the specified Intel Server Products. The tables use the following notations: Doc: Intel intends to update the appropriate documentation in a future revision. Fix: Intel intends to fix this erratum in the future. Fixed: This erratum has been previously fixed. No Fix: There are no plans to fix this erratum.
Monthly Specification Update No. Plans Description of Errata ® 25. Fixed Intel FDR InfiniBand* ConnectX* -3 I/O Module may not comply with FCC and Industry Canada regulations. 26. Fixed The Intel Xeon Phi™ Coprocessor PCI Express* Card Status Sensor may show "Unknown" 27. Fixed The Intel Xeon Phi™ Coprocessor PCI Express* Card sensors numbering may not be consistent with riser slot numbering. 28. Fixed The Activity/Link LED of the the Intel® I/O Expansion Modules may not be solid green 29.
Monthly Specification Update Errata 1. Linux* Operating Systems are not supported on RSTe mode Problem Intel® RSTe mode is not supported on Red Hat* Linux and SUSE* Linux. Implication User may not able to install Red Hat* Linux and SUSE* Linux on Intel® C600 Series Chipset based Server Boards under Intel® RSTe mode. Status This issue may be fixed in future driver or BIOS releases. Workaround None. 2.
Monthly Specification Update 4. HDD status LEDs do not function under specific configuration Problem If drives are connected through expander to SCU ports and configured under RSTe mode, the HDD status LEDs may not function properly. Implication HDD status LED may not show the HDD locate, HDD fault or RAID rebuild message. Status This issue was fixed in RSTe driver 3.2.0.1134 and later version. Workaround None. 5.
Monthly Specification Update 7. System may halt under specific BIOS configurations Problem Once BIOS options “EFI Optimized Boot” and “Memory Mapped I/O Above 4GB” are both enabled, and RSTe mode is selcted, system may halt during the system POST. Implication User may see system hang with mentioned configuration. Status This issue was fixed in BIOS 01.03.0002 and later version. Workaround None. 8.
Monthly Specification Update 10. Integrated BMC Web Console – Power Statistics page – Minimum wattage reads as zero Problem On some systems the Integrated BMC Web Console Power Statistic page may display the Minimun wattage as zero (0W) after the system has been powered. This reading will stay at zero until the next power cycle of the system. Implication This is an incorrect reading only and does not affect operation. Status This issue was fixed in BMC 01.10.3560 and later version.
Monthly Specification Update 13. The BIOS and ME Firmware can't be updated successfully via Intel® One Boot Flash Update Utility(OFU) under SuSE* Linux Enterprise Server 11* (64-bit) with SP2 Problem OFU will fail to update BIOS & ME under SuSE* Linux Enterprise Server 11* (64-bit) with SP2 Operating System. Implication If the system is running SuSE* Linux Enterprise Server 11* (64-bit) with SP2 Operating System, using OFU to update System Firmware Update Package(SFUP) will fail.
Monthly Specification Update Workaround 16. None. Intel® RAID C600 Upgrade Key replacement Issue Problem With Manageability Engine (ME) Firmware 02.01.05.069, the server may detect the incorrect Storage Control Unit (SCU) Redundant Array of Inexpensive/Independent Disks (RAID) information after installing or replacing the RAID upgrade key. The board or system may still show the previous RAID information even if you replace the key with a new one. Implication With the ME firmware 02.01.05.
Monthly Specification Update [1920x1200,High Color(16bit), 60 Hertz] Status This issue was fixed in BMC 01.16.4010 and later release. Workaround None. 19. Hard drive locate LED may not instantly respond to the locate command if backplane is connected through SAS expander to a RAID controller Problem If backplane is connected through SAS expander to a RAID controller, the hard drive locate LED may not instantly respond to the locate command from the RAID controller.
Monthly Specification Update Workaround 22. None. POST Code Diagnostic LEDs may not be all off after POST has completed Problem The POST Code Diagnostic LEDs should be all off after POST has completed. But the LEDs may show other values after booting to an Operating System. The codes seen could change at any time after POST or have any value. A POST code of “0xD4” has been observed after Microsoft* Windows* Server 2008 R2 completes loading.
Monthly Specification Update 24. System fan speed may not slow down as expected after hot-swapping a failed fan within the Intel® Server System R2000GZ/GL Product Family Problem System does not recognize a hot-swapped fan causing the fans to run at high speed. Implication After a system fan failure, the remaining fans will speed up to maintain proper system cooling. After replacing the failed fan with a new one, the system will continue to operate fans at high speed until a system reboot is performed.
Monthly Specification Update Workaround 27. None. The Intel® Xeon Phi™ Coprocessor PCI Express* Card sensors numbering may not be consistent with riser slot numbering Problem The Intel® Xeon Phi™ Coprocessor PCI Express* Card (MIC card) sensors numbering may not be consistent with riser slot numbering on the server board.
Monthly Specification Update 29. Intel® FDR InfiniBand* ConnectX* -3 I/O Module AXX2FDRIBIOM port 2 may have interconnect problem with Mellanox* 1m FDR or 7m SFP+ passive copper cables Problem Intel® FDR InfiniBand* ConnectX* -3 I/O Module AXX2FDRIBIOM port 2 may have interconnect problem when used with Mellanox* 1 meter FDR or 7 meters SFP+ passive copper cables.
Monthly Specification Update Assembly) numbers: G11481-352, G11481-353, G29051-353, G11481-354, and G29051-354. The Intel® Server Board S2600GZ/GL with other PBA numbers are not impacted. The PBA number can be found on the label attached to the server board or in the server board FRU (Field Replaceable Unit) information.
Monthly Specification Update Implication Customers may observe a system hang when using the 3ware® RAID controller card to create RAID logic volume. Status This issue was fixed by BIOS R02.03.0001 and later release. Workaround None. 34. Updated Technical product specification (TPS) rev2.3 -- Remove the “Battery Failure” from Table37 and Table51. 35.