Technical Advisory

This Technical Advisory describes an issue which may or may not affect the customer’s product
Intel Technical Advisory TA1068
5200 NE Elam Young Parkway
Hillsboro, OR 97124
September 23, 2014
Copyright © 2014 Intel Corporation. * Other names and brands may be claimed as the property of others.
The Intel
®
Remote Management Module 4 (RMM4) Dedicated NIC for the
Intel
®
Server Board S2600JF/S2600WP/S1600JP4 encounters link down
issue or experiences high package loss rate under 1Gbps link
Description
Customers have observed abnormal link issues on Intel
®
Compute Module HNS2600JF/HNS2600WP/BBS1600JP4
with an RMM4 NIC module installed:
Login attempt failures through the BMC remote management NIC port
Timeout errors with ISO image transmissions during the media redirection
Root Cause
The network package loss rate on failed components is higher than 24.2%. The high package loss rate can lead to link
issues.
Corrective Action / Resolution
Intel recommends that customers update to the latest BMC 1.21.6593 revision, which will limit the highest link speed
of the dedicated management port to 100Mbps. This may result in a performance drop for the management port
when large-size files are transmitted with the media redirection function enabled. Customers should validate and test
using their normal network traffic to assess impact to their configuration.
Products Affected
The following Intel
®
Server Spare Products are potentially affected by this issue:
Product Name
Product Code
MM#
Intel
®
RMM4 IO Module carrier for HNS2600JF family
AXXRMM4IOM
918249
Intel
®
RMM4 IO Module carrier for HNS2600WP family
AXXRMM4IOMW
918304
Intel
®
RMM4 IO Module carrier for R1000JP4 family
A1UJPRMM4IOM
924114
Please contact your Intel Sales Representative if you require more specific information about this issue.