Intel® Server System R2000GZ/GL Product Family Technical Product Specification Revision 2.
Intel® Server System R2000GZ/GL Product Family TPS Revision History Date January 2012 April 2012 Revision Number 1.0 1.
® Intel Server System R2000GZ/GL Product Family Date Revision Number Modifications Appendix A Revision 2.
Intel® Server System R2000GZ/GL Product Family TPS Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT.
® Intel Server System R2000GZ/GL Product Family TPS Table of Contents 1. Introduction ........................................................................................................................ 1 1.1 Chapter Outline...................................................................................................... 1 1.2 Server Board Use Disclaimer ................................................................................. 1 1.3 Product Errata ..........................................
® Intel Server System R2000GZ/GL Product Family TPS 3.7.3 DC Inrush Current................................................................................................ 26 3.7.4 DC Input Under Voltage ....................................................................................... 26 3.7.5 DC Holdup Time and Dropout .............................................................................. 26 3.7.6 DC Line Surge Voltages (Line Transients) .....................................................
® Intel Server System R2000GZ/GL Product Family TPS 7.3 Intel® Integrated RAID Module Support (Available Option) ................................... 54 7.4 Intel® SAS Expander Support .............................................................................. 55 7.4.1 24-Port PCIe Intel® RAID Expander Card RES2SV240 ........................................ 56 7.4.2 24-Port and 36-Port Internal Intel RAID Expander Cards ..................................... 56 7.4.3 SAS Expander Usage Guidelines .......
® Intel Server System R2000GZ/GL Product Family TPS List of Figures Figure 1. Chassis Dimensions .................................................................................................... 6 Figure 2. System Components Overview .................................................................................... 8 Figure 3. 3.5" Hard Drive Bay - 8 Drive Configuration ................................................................. 8 Figure 4. 3.5" Hard Drive Bay - 12 Drive Configuration .........
® Intel Server System R2000GZ/GL Product Family TPS Figure 43. 36-Port Expander SAS Connector/Drive Identification Block Diagram ..................... 58 Figure 44. Front I/O Panel Features ......................................................................................... 60 Figure 45. Front Control Panel Features................................................................................... 61 Figure 46. Intel Local Control Panel Option .........................................................
® Intel Server System R2000GZ/GL Product Family TPS List of Tables Table 1. System Feature Set ...................................................................................................... 4 Table 2. System Environmental Limits Summary ........................................................................ 7 Table 3. Power Supply Module Output Power Connector Pin-out ............................................. 18 Table 4. Riser Slot Power Pin-out ("OPT_12V_PWR_#") .............................
® Intel Server System R2000GZ/GL Product Family TPS < This page intentionally left blank. > Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS 1. Introduction This Technical Product Specification (TPS) provides system level information for the Intel® Server System R2000GZ and Intel® Server System R2000GL product families. The system level features of both these product families are common, however the server board integrated into them is different.
® Intel Server System R2000GZ/GL Product Family TPS 1.3 Product Errata The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Product Errata are documented in the Intel® Server Board S2600GZGL, Intel® Server System R1000GZGL, Intel® Server System R2000GZGL Monthly Specification Update which can be downloaded from Intel.com 2 Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS 2. Product Family Overview This generation of Intel 2U server platforms offers a variety of system options to meet the varied configuration requirements of high-density high-performance computing environments. The Intel® Server System R2000GZ/GL product family includes several available 2U rack mount server systems that are integrated with either an Intel® Server Board S2600GZ or Intel® Server Board S2600GL.
® Intel Server System R2000GZ/GL Product Family TPS Table 1.
® Intel Server System R2000GZ/GL Product Family TPS Power Supply Options The server system can have up to two power supply modules installed, providing support for the following power configurations: 1+0, 1+1 Redundant Power, and 2+0 Combined Power Two power supply options: AC 460W Gold AC 750W Platinum DC 750W Gold Storage Bay Options 8x – 3.5” SATA/SAS Hot Swap Hard Drive Bays + Optical Drive support 12x – 3.5” SATA/SAS Hot Swap Hard Drive Bays 8x – 2.
® Intel Server System R2000GZ/GL Product Family TPS 2.1 Chassis Dimensions Figure 1. Chassis Dimensions 6 Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS 2.2 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 2. System Environmental Limits Summary Parameter Limits Temperature Operating ASHRAE Class A2 – Continuous Operation. 10º C to 35º C (50º F to 95º F) with the maximum rate of change not to exceed 10°C per hour ASHRAE Class A3 – Includes operation up to 40C for up to 900 hrs per year.
® Intel Server System R2000GZ/GL Product Family TPS Disclaimer Note: Intel ensures the unpackaged server board and system meet the shock requirement mentioned above through its own chassis development and system configuration. It is the responsibility of the system integrator to determine the proper shock level of the board and system if the system integrator chooses different system configuration or different chassis.
® Intel Server System R2000GZ/GL Product Family TPS Figure 4. 3.5" Hard Drive Bay - 12 Drive Configuration Note: Each set of four drives with a common color device ID represents a common SATA/SAS cable interface connector on the backside of the backplane. Figure 5. 2.5" Hard Drive Bay - 8 Drive Configuration Figure 6. 2.5" Hard Drive Bay - 16 Drive Configuration Figure 7. 2.5" Hard Drive Bay - 24 Drive Configuration Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS Note: Each set of four drives with a common color device ID represent a common SATA/SAS cable interface connector on the backside of the backplane. 2.3.2 Back Panel Features Figure 8. Back Panel Feature Identification 2.3.
® Intel Server System R2000GZ/GL Product Family TPS 2.4 Server Board Features Overview The following illustration provides a general overview of the server board, identifying key feature and component locations. The majority of the items identified are common between the Intel® Server Board S2600GL and S2600GZ. Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS ® Figure 10. Intel Server Board S2600GZ Label A B C D E F G H 12 Description System ID System Status POST Code Diagnostics 12V Stand-by Power Present CPU-2 Fault System Fan #6 Fan Fault System Fan #5 Fan Fault System Fan #4 Fan Fault Label I J K L M N O Description System Fan #3 Fan Fault Memory Fault System Fan #2 Fan Fault System Fan #1 Fan Fault CPU-1 Fault CATERR System Power Good Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS ® Figure 11. Intel Light-Guided Diagnostic LEDs - Server Board 2.5 Available Front Bezel Support The optional front bezel is made of Black molded plastic and uses a snap-on design. When installed, its design allows for maximum airflow to maintain system cooling requirements. (Intel Product Order Code – A2UBEZEL) The face of the bezel assembly includes snap-in identification badge options and a wave feature option to allow for customization.
® Intel Server System R2000GZ/GL Product Family TPS Figure 13. Front Bezel accessory with optionally installed wave and ID badge (1) Figure 14. Front Bezel accessory with optionally installed wave and ID badge (2) 14 Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS Figure 15. Front Bezel accesssory ID Badge mechanical drawings 2.6 Available Rack and Cabinet Mounting Kit Options Advisory Note – Available rack and cabinet mounting kits are not designed to support shipment of the server system while installed in a rack. If you choose to do so, Intel advises you verify your shipping configuration with appropriate shock and vibe testing, before shipment.
® Intel Server System R2000GZ/GL Product Family TPS 3. Power Subsystem This chapter provides a high level overview of the power management features and specification data for the power supply options available for this server product. Specification variations will be identified for each supported power supply.
® Intel Server System R2000GZ/GL Product Family TPS Airflow direction 2mm B25 Retention Latch A25 185mm FCI 2x25 card edge connector 10035388-102 74mm B1 A1 11mm 40mm fan 39mm 8.5mm Figure 16. Power Supply Module Mechanical Drawing Figure 17. Power Supply Module Figure 18. AC and DC Power Supply - Connector Views Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS 3.2 3.2.1 Power Connectors Power Supply Module Card Edge Connector Each power supply module has a single 2x25 card edge output connection that plugs directly into a matching slot connector on the server board. The connector provides both power and communication signals to the server board. The following table defines the connector pin-out. Table 3.
® Intel Server System R2000GZ/GL Product Family TPS Each connector is labeled as “OPT_12V_PWR_1” and “OPT_12V_PWR_2” on the server board. The following table provides the pin-out for both connectors. Table 4.
® Intel Server System R2000GZ/GL Product Family TPS 3.3 Power Supply Module Efficiency The following tables provide the required minimum efficiency level at various loading conditions. These are provided at three different load levels: 100%, 50% and 20%. Efficiency is tested over an AC input voltage range of 115 VAC to 220 VAC. Table 7. 460 Watt AC Power Supply Efficiency (Gold) Loading Minimum Efficiency 100% of maximum 88% 50% of maximum 92% 20% of maximum 88% 10% of maximum 80% Table 8.
® Intel Server System R2000GZ/GL Product Family TPS Figure 20. DC Power Cord Table 11. DC Power Cable Connector Pin-out 3.5 Pin Definition 1 + Return 2 Safety Ground 3 - 48V Optional Chassis Grounding Support The system provides 10-32 threaded grounding studs on the back panel of the chassis, allowing for optional system grounding via a grounding strap. Figure 21.
® Intel Server System R2000GZ/GL Product Family TPS 3.6 AC Power Supply Input Specifications The following sections provide the AC Input Specifications for systems configured with AC power supply modules. 3.6.1 Power Factor The power supply must meet the power factor requirements stated in the Energy Star® Program Requirements for Computer Servers. These requirements are stated below. Output power Power factor 10% load > 0.65 20% load > 0.80 50% load > 0.90 100% load > 0.
® Intel Server System R2000GZ/GL Product Family TPS 3.6.4.1 AC Line 12VSBHoldup The 12VSB output voltage should stay in regulation under its full load (static or dynamic) during an AC dropout of 70ms min (=12VSB holdup time) whether the power supply is in ON or OFF state (PSON asserted or deasserted). 3.6.5 AC Line Fuse The power supply shall have one line fused in the single line fuse on the line (Hot) wire of the AC input. The line fusing shall be acceptable for all safety agency requirements.
® Intel Server System R2000GZ/GL Product Family TPS Table 15. Performance Criteria Level A B C 3.6.9 Description The apparatus shall continue to operate as intended. No degradation of performance. The apparatus shall continue to operate as intended. No degradation of performance beyond spec limits. Temporary loss of function is allowed provided the function is self-recoverable or can be restored by the operation of the controls.
® Intel Server System R2000GZ/GL Product Family TPS Table 16. 460 Watt Power Supply Over Current Protection Output Voltage +12V 12VSB Input voltage range 90 – 264VAC 90 – 264VAC Over Current Limits 47A min; 55A max 2A min; 2.5A max Table 17. 750 Watt Power Supply Over Current Protection Output Voltage +12V 12VSB 3.6.15.2 Input voltage range 90 – 264VAC 90 – 264VAC Over Current Limits 72A min; 78A max 2.5A min; 3.
® Intel Server System R2000GZ/GL Product Family TPS 3.7.1 DC Input Voltage The power supply must operate within all specified limits over the following input voltage range. Table 19. DC Input Rating PARAMETER DC Voltage Input Current 3.7.2 MIN -40.5 VDC 24A RATED -48VDC/-60VDC MAX -75VDC 12.5A DC Input Fuse The power supply shall have the –48VDC input fused. The fusing shall be acceptable for all safety agency requirements. DC inrush current shall not cause the fuse to blow under any conditions.
® Intel Server System R2000GZ/GL Product Family TPS Table 20. Line Voltage Transient Limits Duration 200µs max 3.7.
® Intel Server System R2000GZ/GL Product Family TPS 3.7.8.1 Current Limit (OCP) The power supply shall have current limit to prevent the outputs from exceeding the values shown in table below. If the current limits are exceeded the power supply shall shutdown and latch off. The latch will be cleared by toggling the PSON# signal or by an DC power interruption. The power supply shall not be damaged from repeated power cycling in this condition. 12VSB will be auto-recovered after removing OCP limit.
® Intel Server System R2000GZ/GL Product Family TPS subsystem to shutdown or become over loaded. The default state of the power subsystem is all power supplies ON. There needs to be at least one power supply in Cold Redundant Active state or Standard Redundant state to allow the Cold Standby state power supplies to go into Cold Standby state. 3.8.
® Intel Server System R2000GZ/GL Product Family TPS 3.9 Closed Loop System Throttling (CLST) The server system has support for Closed Loop System Throttling (CLST). CLST prevents the system from crashing if a power supply module is overloaded. Should system power reach a pre-programmed power limit, CLST will throttle system memory and/or processors to reduce power. System performance will be impacted should this occur.
® Intel Server System R2000GZ/GL Product Family TPS 4. Thermal Management The fully integrated system is designed to operate at external ambient temperatures of between 10ºC- 35ºC with limited excursion based operation up to 45ºC, as specified in Table 2. System Environmental Limits Summary.
® Intel Server System R2000GZ/GL Product Family TPS • • • • • • 4.2 System Configuration - 16x 2.5” hard drive bay or 8x 3.5” hard drive bay configuration + Intel® Server Board S2600GZ (24 DIMM server board) Memory slot 3 populated on all memory channels System Configuration - 24x 2.5” hard drive bay or 12x 3.5” hard drive bay configuration + Intel® Server Board S2600GL (16 DIMM server board) Memory slot 2 populated on all memory channels All hard drive bays must be populated.
® Intel Server System R2000GZ/GL Product Family TPS BIOS Setup (BIOS>Advanced>System Acoustic and Performance Configuration) allow for parameter adjustments based on the actual system configuration and usage. Refer to the following sections for a description of each setting. 4.2.1 Set Throttling Mode This option is used to select the desired memory thermal throttling mechanism. Available settings include: [Auto], [DCLTT], [SCLTT] and [SOLTT].
® Intel Server System R2000GZ/GL Product Family TPS The following IPMI thermal sensors are used as input to fan speed control: • • • • • • • • • • • • • • • Front Panel Temperature Sensor1 CPU Margin Sensors2,4,5 DIMM Thermal Margin Sensors2,4 Exit Air Temperature Sensor1, 7, 9 PCH Temperature Sensor3,5 On-board Ethernet Controller Temperature Sensors3, 5 Add-In Intel SAS/IO Module Temperature Sensors3, 5 PSU Thermal Sensor3, 8 CPU VR Temperature Sensors3, 6 DIMM VR Temperature Sensors3, 6 BMC Temperatur
® Intel Server System R2000GZ/GL Product Family TPS 4.3 System Fans Five 60x38-mm fans and an embedded fan for each installed power supply, provide the primary airflow for the system. The following table provides the volumetric air flow requirements for different 2U system configurations. Table 25. 2U System Volumetric Air Flow Requirements System Configuration Air Flow Range (CFM) 3.5” x 12 drives 20 – 96 CFM 2.
® Intel Server System R2000GZ/GL Product Family TPS Figure 24. System Fan Assembly The system fan assembly is designed for ease of use and supports several features. Each fan is hot-swappable. Each fan is designed for tool-less insertion and extraction from the fan assembly. For instructions on installing or removing a fan module, see the Intel® Server System R2000GZ/GL Service Guide. Fan speed for each fan is controlled by the integrated BMC on the server board.
® Intel Server System R2000GZ/GL Product Family TPS Table 26.
® Intel Server System R2000GZ/GL Product Family TPS Intel® Xeon Phi™ Coprocessor and GPGPU Add-in Card Support 5. Some (not all) system configurations of the Intel® Server System R2000GZ/GL product family have thermal and mechanical support for Intel® Xeon Phi™ Coprocessor cards and non-Intel GPGPU add-in cards. Which card and system configurations can be supported is dependent on power and thermal limits of the system, and power and thermal requirements of the add-in card.
® Intel Server System R2000GZ/GL Product Family TPS With a 2-slot riser card installed, the embedded fan speed control will operate system fans at a higher speed. 3-slot riser cards (as shipped in the standard platform configuration) cannot be used due to air flow and thermal limitations. NOTE: The latest posted system software updates must be installed on the system to ensure proper fan speed control is enabled.
® Intel Server System R2000GZ/GL Product Family TPS • A system configured with the contents of Intel Accessory Kit AGZCOPRODUCT can support the following add-in card configurations. o Add-in cards with minimum 100 LFM (0.5 m/s) or 200 LFM (1m/s) air flow requirement can be installed in any available add-in card slot in both Riser Card #1 and Riser Card #2. o Add-in cards with a >200 LFM air flow requirement cannot be supported.
® Intel Server System R2000GZ/GL Product Family TPS 6. System Storage and Peripheral Drive Bays Overview The Intel® Server System R2000GZ/GL product family has support for many storage device options, including: • • • • • • Hot Swap 2.5” Drives Hot Swap 3.5” Drives SATA Optical Drive SATA Solid State Devices (SSDs) SATA DOMs Low Profile (2mm) eUSB Solid State Device (eUSB SSD) Support for different storage and peripheral device options will vary depending on the system SKU.
® Intel Server System R2000GZ/GL Product Family TPS Figure 28. 2.5" Drive Bay - 24 Drive Configuration The drive bay can support either SATA or SAS hard disks or SSDs. Mixing of drive technologies (SATA/SAS) within a common hot swap backplane is not supported. Systems with multiple hot swap backplanes can support different drive type configurations as long as the drives attached to a common backplane are the same and the installed controller attached to the given backplane can support the drive type.
® Intel Server System R2000GZ/GL Product Family TPS Table 28. Drive Activity LED States Condition Power on with no drive activity Green Power on with drive activity Power on and drive spun down Power on and drive spinning up 6.1.1 Drive Type SAS SATA SAS SATA SAS SATA SAS SATA Behavior LED stays on LED stays off LED blinks off when processing a command LED blinks on when processing a command LED stays off LED stays off LED blinks LED stays off 2.
® Intel Server System R2000GZ/GL Product Family TPS On the backside of each backplane are several connectors. The following illustration identifies each.
® Intel Server System R2000GZ/GL Product Family TPS 6.2 3.5” Drive Support The server is available in 3.5” form factor storage device configurations of 8 and 12 devices as illustrated below. Label A B C D E F Description System Label Pull-out Tab SATA Optical Drive Video Connector USB Ports Front Control Panel 3.5” Hard Drive Bays Figure 29. 3.5" Drive Bay - 8 Drive Configuration Figure 30. 3.
® Intel Server System R2000GZ/GL Product Family TPS Note: To maintain system thermals, all drive bays must be populated with a drive tray mounted with a hard disk drive, SSD, or supplied drive blank. The provided 3.5” drive blank can also be used as a 2.5” device bracket, allowing a 2.5” SSD to be installed into a 3.5” device carrier. Figure 31. Option to install 2.5” SSD into a 3.5” drive blank Note: Due to degraded performance and reliability concerns, the use of the 3.5” drive blank as a 2.
® Intel Server System R2000GZ/GL Product Family TPS Amber Off Solid On Blink No access and no fault Hard Drive Fault has occured RAID rebuild in progress (1 Hz), Identify (2 Hz) Condition Power on with no drive activity Green Power on with drive activity Power on and drive spun down Power on and drive spinning up 6.2.
® Intel Server System R2000GZ/GL Product Family TPS Label A B C Description 4-port mini-SAS connectors Power connectors SMBus connector A – 4-port Mini-SAS Connectors – The backplane includes two or three multi-port mini-SAS cable connectors, each providing SGPIO and I/O signals for four SAS/SATA hard drives on the backplane. Cables can be routed from matching connectors on the server board, add-in SAS/SATA RAID cards, or an optionally installed SAS expander card.
® Intel Server System R2000GZ/GL Product Family TPS 6.3 Optical Drive Support Systems configured with eight 3.5” hard drive bays or up to sixteen 2.5” hard drive bays also include support for an optical drive bay ‘A’ as illustrated below. Figure 32. Optical Drive Support A 2x3 pin power connector on the server board labeled “ODD/SSD PWR” is designed to provide power to two SATA SSDs or a single SATA SSD and a SATA optical drive.
® Intel Server System R2000GZ/GL Product Family TPS 6.4 Internal – Fixed Mount Solid State Drive (SSD) Support The system can support up to two internal fixed mount 2.5” Solid State Drives (SSD). Each drive is attached to the top side of the air duct as illustrated below. Figure 33. 2.5" Solid State Drive (SSD) Mounting Option A 2x3 pin power connector on the server board labeled “ODD/SSD PWR” is designed to provide power to both SSDs or a single SSD and an optical drive.
® Intel Server System R2000GZ/GL Product Family TPS 6.5 Low Profile eUSB SSD Support The system provides support for a low profile eUSB SSD storage device. A 2mm 2x5-pin connector labeled “eUSB SSD” near the rear I/O section of the server board is used to plug this small flash storage device into. Bottom View Top View Figure 34. Low Profile eUSB SSD Support eUSB features include: • • • • 6.6 2 wire small form factor Universal Serial Bus 2.
® Intel Server System R2000GZ/GL Product Family TPS 7. Storage Controller Options Overview The server platform supports many different embedded and add-in SATA/SAS controller and SAS Expander options to provide a large number of possible storage configurations. This section will provide an overview of the different options available. 7.
® Intel Server System R2000GZ/GL Product Family TPS 7.2 Embedded Software RAID Support The system includes support for two embedded software RAID options: • • Intel® Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW RAID technology Intel® Rapid Storage Technology (RSTe) Pressing the key to enter the BIOS Setup Utility during system POST, options are available to enable/disable SW RAID, and select which embedded software RAID option to use.
® Intel Server System R2000GZ/GL Product Family TPS 7.3 Intel® Integrated RAID Module Support (Available Option) The system has support for many Intel and 3rd party PCIe add-in RAID adapters which can be installed in available PCIe add-in cards slots. For system configurations with limited add-in card slot availability, an optional Intel® Integrated RAID mezzanine module can be installed onto a high density 80-pin connector (labeled “SAS Module”) on the server board. ® Table 30.
® Intel Server System R2000GZ/GL Product Family TPS Figure 36. AXXBBU9 Installation Figure 37.
® Intel Server System R2000GZ/GL Product Family TPS Intel® RAID Expander Features: • • • • • • • • • • • • • • 7.4.1 SAS protocol, described in the Serial Attached SCSI (SAS) Standard, version 2.
® Intel Server System R2000GZ/GL Product Family TPS Figure 39. Internal SAS Expander Installation The following diagrams are used to help identify the mini-SAS connectors found on the SAS expander cards. Care should be taken when connecting connectors from the SAS expander to the connectors on the backplane because each connector is pre-programmed at the factory to provide specific drive identification mapping. Improper connections may provide undesirable drive mappings. Figure 40.
® Intel Server System R2000GZ/GL Product Family TPS Figure 42. Internal 36-Port SAS Expander Card (RES2CV360) 0-3 4-7 24-27 28-31 32-35 A B G H I 8 7 36-port SAS 6 0 6Gb 5 1 Expander 4 2 3 8-11 12-15 16-19 20-23 C D E F Figure 43. 36-Port Expander SAS Connector/Drive Identification Block Diagram Each connector on the SAS expander card can be used as a “cable in” (SAS Controller to SAS Expander) or “cable out” (SAS Expander to Hot Swap Backplane) type connector.
® Intel Server System R2000GZ/GL Product Family TPS 7.4.4.1 Cable Routing using the both embedded SCU ports and a SAS Expander Card (RSTe only) SCU controller limitations prevent both SCU mini-SAS connectors on the server board from being attached to the same expander card. Therefore, in order to use both embedded SCU ports with a SAS expander card, one SCU port is connected directly to backplane and one SCU port is connected to the expander card.
® Intel Server System R2000GZ/GL Product Family TPS 8. Front Control Panel and I/O Panel Overview All system configurations will include a Control Panel on the front of the system providing push button system controls and LED indicators for several system features. Systems configured with eight 3.5” hard drive bays or up to sixteen 2.5” hard drive bays will also include an I/O Panel providing additional system I/O features. This section describes the features and functions of both front panel options.
® Intel Server System R2000GZ/GL Product Family TPS Label A Description System ID Button w/Integrated LED Label F Description System Status LED B NMI Button (recessed, tool required for use) G Power / Sleep Button w/Integrated LED C NIC-1 Activity LED H Hard Drive Activity LED D NIC-3 Activity LED I NIC-4 Activity LED E System Cold Reset Button J NIC-2 Activity LED Figure 45.
® Intel Server System R2000GZ/GL Product Family TPS F – System Status LED – The System Status LED is a bi-color (Green/Amber) indicator that shows the current health of the server system. The system provides two locations for this feature; one is located on the Front Control Panel, the other is located on the back edge of the server board, viewable from the back of the system. Both LEDs are tied together and will show the same state.
® Intel Server System R2000GZ/GL Product Family TPS Amber Solid on Critical, nonrecoverable – System is halted Fatal alarm – system has failed or shutdown: CPU CATERR signal asserted MSID mismatch detected (CATERR also asserts for this case). CPU 1 is missing CPU Thermal Trip No power good – power fault DIMM failure when there is only 1 DIMM present and hence no good 1 memory present . Runtime memory uncorrectable error in non redundant mode.
® Intel Server System R2000GZ/GL Product Family TPS 9. Intel® Local Control Panel The Intel® Local Control Panel option (Intel Product Order Code – A1U2ULCP) utilizes a combination of control buttons and LCD display to provide system accessibility and monitoring. Label A B C D E F Description LCD Display Left Control Button “Enter” Button Right Control Button USB 2.0 Port USB 2.
® Intel Server System R2000GZ/GL Product Family TPS 10. PCI Riser Card Support The system includes two riser card slots on the server board. Available riser cards can be used in either slot. This section will provide an overview of each available riser card and describe the server board features and architecture supporting them. 10.1 Riser Slot Overview The server board includes two riser card slots labeled “RISER 1” and “RISER 2”.
® Intel Server System R2000GZ/GL Product Family TPS ® Figure 48. Intel Server Board S2600GZ/GL PCI Bus Layout Diagram 66 Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS 10.2 Riser Card Assembly The system includes two riser card assemblies which include a riser card bracket and a riser card. The riser card bracket will accept riser cards with up to three add-in card slots Figure 49.
® Intel Server System R2000GZ/GL Product Family TPS Thermally, the system can support the following PCI add-in cards. • Add-in cards with a minimum 100 LFM (0.5 m/s) air flow requirement can be installed in any available add-in card slot in both Riser Card #1 and Riser Card #2 • Add-in cards with a minimum 200 LFM (1 m/s) air flow requirement can be installed in any available add-in card slot on Riser Card #2 and the bottom add-in card slot on Riser Card #1.
® Intel Server System R2000GZ/GL Product Family TPS 10.3.2 2-Slot PCIe Riser Card Slot # 10.3.3 Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS 10.4 PCIe Add-in card support The PCIe sub-system of the server board has support for PCIe add-in cards that follow the PCIe Gen1, Gen2 and Gen3 specifications. However, the performance of some PCIe Gen3 cards may be forced to operate at Gen2 speeds due to electrical signaling characteristic limitations that exist between the server board and some PCIe Gen 3 add-in cards.
® Intel Server System R2000GZ/GL Product Family TPS The “Processor PCIe Link Speed” menu will display selectable options for each installed processor, identified as “Socket #”, where # identifies the CPU number. Using information provided in the following tables, select the processor associated with the PCIe port to be configured. Table 33. Riser Slot #1 – PCIe Port Routing Riser Slot #1 – Riser Card Options Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS Table 34.
® Intel Server System R2000GZ/GL Product Family TPS Select the desired PCIe Gen level. After making all desired changes in BIOS setup, be sure to save the changes and reboot the system. Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS 11. Mezzanine Module Support 11.1 IO Module Support In addition to the embedded I/O features of the server board, and those available with the addition of a PCIe add-in card, the server also provides concurrent support of an optionally installed mezzanine I/O module. The following table lists the Intel® I/O modules available for this server.
® Intel Server System R2000GZ/GL Product Family TPS On the server board each Intel® RMM4 component is installed at the following locations. ® Figure 51. Intel RMM4 Dedicated Management NIC Installation ® Figure 52. Intel RMM4 Lite Activation Key Installation Table 35.
® Intel Server System R2000GZ/GL Product Family TPS Appendix A: Integration and Usage Tips This section provides a list of useful information that is unique to the Intel® Server System R2000GZ/GL Product Family and should be kept in mind while configuring your server system. • • • • • • • • • • 76 Only the Intel® Xeon® processor E5-2600 and the Intel® Xeon® processor E5-2600 V2 product families are supported in this Intel® Server System. Previous generation Intel® Xeon® processors are not supported.
® Intel Server System R2000GZ/GL Product Family TPS Appendix B: POST Code Diagnostic LED Decoder As an aid to assist in trouble shooting a system hang that occurs during a system’s Power-On Self Test (POST) process, the server board includes a bank of eight POST Code Diagnostic LEDs on the back edge of the server board.
® Intel Server System R2000GZ/GL Product Family TPS Table 37. Diagnostic LED POST Code Decoder Diagnostic LED Decoder 1 = LED On, 0 = LED Off Lower Nibble Checkpoint Upper Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED # #7 #6 #5 #4 #3 #2 #1 #0 Description SEC Phase 01h 0 0 0 0 0 0 0 1 First POST code after CPU reset 02h 0 0 0 0 0 0 1 0 Microcode load begin 03h 0 0 0 0 0 0 1 1 CRAM initialization begin 04h 0 0 0 0 0 1 0 0 Pei Cache When Disabled 05h 0 0 0 0 0 1 0 1 SEC Core At Power On Begin.
® Intel Server System R2000GZ/GL Product Family TPS Diagnostic LED Decoder 1 = LED On, 0 = LED Off Lower Nibble Checkpoint Upper Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED # #7 #6 #5 #4 #3 #2 #1 #0 Description A3h 1 0 1 0 0 0 1 1 DXE IDE detect A4h 1 0 1 0 0 1 0 0 DXE IDE enable A5h 1 0 1 0 0 1 0 1 DXE SCSI begin A6h 1 0 1 0 0 1 1 0 DXE SCSI reset A7h 1 0 1 0 0 1 1 1 DXE SCSI detect A8h 1 0 1 0 1 0 0 0 DXE SCSI enable A9h 1 0 1 0 1 0 0 1 DXE verifying SETUP password ABh 1 0 1 0 1 0 1 1 DXE SETUP start ACh
® Intel Server System R2000GZ/GL Product Family TPS POST Memory Initialization MRC Diagnostic Codes There are two types of POST Diagnostic Codes displayed by the MRC during memory initialization; Progress Codes and Fatal Error Codes. The MRC Progress Codes are displays to the Diagnostic LEDs that show the execution point in the MRC operational path at each step. Table 38.
® Intel Server System R2000GZ/GL Product Family TPS Table 39. MRC Fatal Error Codes Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble Description MSB LED LSB 8h 4h 2h 1h 8h 4h 2h 1h #7 #6 #5 #4 #3 #2 #1 #0 MRC Fatal Error Codes E8h E9h 1 1 1 0 1 0 0 0 1 1 1 0 1 0 0 1 1 1 1 0 1 0 1 0 1 1 1 0 1 0 1 1 1 1 1 0 1 1 0 1 1 1 1 0 1 1 1 1 EAh EBh EDh EFh Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS Appendix C: POST Code Errors Most error conditions encountered during POST are reported using POST Error Codes. These codes represent specific failures, warnings, or are informational. POST Error Codes may be displayed in the Error Manager display screen, and are always logged to the System Event Log (SEL). Logged events are available to System Management applications, including Remote and Out of Band (OOB) management.
® Intel Server System R2000GZ/GL Product Family TPS Error Code 8132 8133 8160 8161 8162 8163 8170 8171 8172 8173 8180 8181 8182 8183 8190 8198 8300 8305 83A0 83A1 84F2 84F3 84F4 84FF 8500 8501 8520 8521 8522 8523 8524 8525 8526 8527 8528 8529 852A 852B 852C 852D 852E 852F 8530 8531 8532 8533 8534 8535 8536 8537 8538 8539 853A 853B 853C 853D 853E 853F (Go to 85C0) 8540 8541 Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS Error Code 8542 8543 8544 8545 8546 8547 8548 8549 854A 854B 854C 854D 854E 854F 8550 8551 8552 8553 8554 8555 8556 8557 8558 8559 855A 855B 855C 855D 855E 855F (Go to 85D0) 8560 8561 8562 8563 8564 8565 8566 8567 8568 8569 856A 856B 856C 856D 856E 856F 8570 8571 8572 8573 8574 8575 8576 8577 8578 8579 857A 857B 857C 857D 84 Error Message DIMM_A3 disabled DIMM_B1 disabled DIMM_B2 disabled DIMM_B3 disabled DIMM_C1 disabled DIMM_C2 disabled DIMM_C3 disabl
® Intel Server System R2000GZ/GL Product Family TPS Error Code 857E 857F (Go to 85E0) 85C0 85C1 85C2 85C3 85C4 85C5 85C6 85C7 85C8 85C9 85CA 85CB 85CC 85CD 85CE 85CF 85D0 85D1 85D2 85D3 85D4 85D5 85D6 85D7 85D8 85D9 85DA 85DB 85DC 85DD 85DE 85DF 85E0 85E1 85E2 85E3 85E4 85E5 85E6 85E7 85E8 85E9 85EA 85EB 85EC 85ED 85EE 85EF 8604 8605 8606 92A3 92A9 A000 A001 A002 A003 A100 Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS Error Code A421 A5A0 A5A1 A6A0 Error Message PCI component encountered a SERR error PCI Express component encountered a PERR error PCI Express component encountered an SERR error DXE Boot Service driver: Not enough memory available to shadow a Legacy Option ROM Response Fatal Minor Fatal Minor POST Error Beep Codes The following table lists the POST error beep codes.
® Intel Server System R2000GZ/GL Product Family TPS Appendix D: System Configuration Table for Thermal Compatibility The following list reflects specified notes identified in the “Support Notes” column in the table. Each note reflects support criteria associated with a specific system configuration. Notes not specified in the table will reflect support criteria for a R1000GZ/GL Base System SKU described in the appropriate 1U Technical Product Specification. Notes: 1.
® Intel Server System R2000GZ/GL Product Family TPS Base System SKUs: R2312GZ/GL ASHRAE 25° C 25° C A2 A3 A4 35° C 40° C Redundant Fan Configuration ● ● ● Redundancy Available ● ● EP, 60w, 6C (E5-2630L) ● ● EP, 70w, 8C (E5-2650L) EP, 95w, 6C (E5-2620 , E5-2630, E52640) ● ● ● ● ● ● EP, 95w, 8C (E5-2650, E5-2660) ● ● ● Intel® Xeon® processor E52600 product family EP, 115w, 8C (E5-2665, E5-2670) ● ● ● EP, 130w, 6C (E5-2667) ● ● EP, 130w, 8C (E5-2680) ● ● EP, 135w, 8C (
® Intel Server System R2000GZ/GL Product Family TPS Base System SKUs: R2312GZ/GL ASHRAE 25° C 25° C A2 A3 A4 35° C 40° C Riser #1 - Bottom Slot (1U riser and 2U riser) ● ● Riser #1 - Middle Slot (2U riser) ● ● Riser #1 - Top Slot (2U riser) Riser #2 - Bottom Slot (1U riser and 2U riser) ● Riser #2 - Middle Slot (2U riser) I/O Modules Intel® Xeon Phi™ or NonIntel GPGPU RAID Battery Backup Internal SSD Revision 2.
® Intel Server System R2000GZ/GL Product Family TPS Glossary Word/Acronym ACA Australian Communication Authority ANSI American National Standards Institute BMC Baseboard Management Controller BIOS Basic Input/Output System CMOS Complementary Metal-oxide-semiconductor D2D DC-to-DC EMP Emergency Management Port FP Front Panel FRB Fault Resilient Boot FRU Field Replaceable Unit 2 90 Definition IC Inter-integrated Circuit bus LCD Liquid Crystal Display LPC Low-pin Count LSB Least
® Intel Server System R2000GZ/GL Product Family TPS Reference Documents See the following documents for additional information: Intel® Server Board S2600GZ/GL Technical Product Specification Intel® Server Board S2600GZ/GL Product Family Spares/Parts List and Configuration Guide Intel® Server System R2000GZ/GL Service Guide Intel® Server System R2000GZ/GL Quick Installation Guide Intel® S2600GZGL Product Family Power Budget and Thermal Configuration Tool BIOS for Platforms Base