Technical Advisory

This Technical Advisory describes an issue which may or may not affect the customer’s product
Intel Technical Advisory TA-1041-1
5200 NE Elam Young Parkway
Hillsboro, OR 97124
November 12, 2013
Copyright © 2013 Intel Corporation. * Other names and brands may be claimed as the property of others.
When a Baseboard Management Controller (BMC) reset occurs due to
an IPMI cold reset command or a firmware update, the BMC firmware
may not restart properly
Products Affected
Intel
®
Server Boards S2600xx product family
Intel
®
Server System R1000xx product family
Intel
®
Server System R2000xx product family
Intel
®
Server System P4000xx product family
Description
Unexpected behavior has been observed when heavy traffic is present on any of the NIC ports available to the
Baseboard Management Controller (BMC), coincident with a BMC reset resulting from either an IPMI cold reset
command, or the reset that occurs after a BMC firmware update. Under these conditions the BMC firmware may not
restart properly.
The BMC will not respond to most IPMI commands after it has entered this state. An additional failure symptom is that
the Chassis ID (Blue LED on baseboard and Front Panel) will continue to blink.
This issue applies to all products listed in the Products Affected section above.
Root Cause
BMC firmware prior to BMC 1.19.5018 did not disable the network services before initiating the reset. Consequently,
network traffic continued to be buffered to memory. This same area of memory is used for different purposes after the
reboot. It is possible that the buffered network traffic would lead to a memory checksum error to be detected by the
BMC firmware. This checksum error would prevent the BMC from booting its operating system and instead go into
firmware update transfer mode.
Corrective Action / Resolution
This issue has been fixed in BMC 1.19.5018 and later.
Workarounds
Disconnecting any NIC ports available to the BMC before performing firmware updates or an IPMI cold reset command
will ensure that this issue will not occur. If the issue occurs, an AC power cycle of the system is required to clear it.
Please contact your Intel Sales Representative if you require more specific information about this issue.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR
IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT.
EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO

Summary of content (2 pages)