Intel® Server System R2000GZ/GL Product Family Quick Installation User's Guide Thank you for buying an Intel® Server System. The following information will help you assemble your Intel® Server System and install components. If you are not familiar with ESD [Electrostatic Discharge] procedures used during system integration, see the complete ESD procedures described in your Service Guide. This guide and other supporting documents are located on the web at: http://www.intel.com/support. * 2.
(This page is intentionally left blank.
Table of Contents System Overview .............................................................................................................................. 1 General Installation Process ........................................................................................................ 2 Preparing the System ....................................................................................................... 2 Remove the Top Cover .................................................................
Warning Warning Caution Read all caution and safety statements in this document before performing any of the instructions. Also see the Intel ® Server Board and Server Chassis Safety Information document at: http://www.intel.com/support/ motherboards/server/sb/cs-010770 .htm for complete safety information. Installation and service of this product to be performed only by qualified service personnel to avoid risk of injury from electrical shock or energy hazard.
System Overview Intel® Server System R2000GZ/GL Product Family System Features and Components Server Board CPU1 CPU2 Add-in Card Riser Assembly 1+1 Redundant Power Supply Modules System Fans Hot Swap Hard Drive Bays Air Duct Optical Drive Bay Front Control Panel * 2.5" Hard Drive Bay system as shown Useful Information: • Riser Slot 2 is not functional without having two processors installed. • The SCU1 (4-7) port requires an Intel® RAID C600 Upgrade Key installed to be functional.
General Installation Process The installation instructions in this section are for common components of Intel® Server System R2000GZ/GL Product Family. 1 Minimum Hardware Requirements To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: Preparing the System Observe normal ESD (Electrostatic Discharge) procedures. • Processor: Intel® Xeon® processor E5-2600 product family.
General Installation Process 5 Install the Processor(s) A. Open the Socket Lever A B B. Open the Load Plate Push down the lever and slide away from the socket to release it. Repeat step A to release the lever on the other side. A Press the locking lever slightly to raise the load plate. B Open the load plate all the way. CL OS E t LG NO NN 1s O XC FO EN U 11 OP CP 0 A2 1s ILM t O 56 EN 17 P NO 2 1s A t CP NOTE: Release the levers in the order as shown.
General Installation Process 6 CAUTION: Do not over-tighten fasteners. CAUTION: The heatsink has thermal interface material (TIM) on the underside of it. Use caution so that you do not damage the thermal interface material. Use gloves to avoid sharp edges. A Remove the protective film on the TIM if present. B Align heatsink fins to the front and back of the chassis for correct airflow. Airflow goes from front-to-back of chassis.
General Installation Process Install Memory Modules ... Continued To Install DIMMs: Open both DIMM socket levers. C Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. D Push down firmly on the DIMM until it snaps into place and both levers close. E IMPORTANT! Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot. C E CAUTION: Avoid touching contacts when handling or installing DIMMs. A B Note location of alignment notch.
General Installation Process Install Hard Drives ... Continued 3.5" Hard Drive Carrier (For system with 3.5" hard drive bay only) Remove the drive carrier by pressing the green button and opening the lever. B Slide the carrier out. C Remove the four screws securing the HDD interface bracket and remove the HDD interface bracket. TO P AB G F T TIN E OF OU IV K M DR EA RE RD BR EFO HA B 5´´ 2. A AB NG F T TI E OF OU IV K M DR EA RE RD BR EFO HA B 5´´ 2.
General Installation Process 9 A Install Optical Drive Install the plastic guide onto the back of the drive and attach with two screws as shown. B Insert the optical drive into chassis opening and push all the way until it stops. C Connect the cables as shown. cal OptiDrive A IMPORTANT NOTE: If you do not install a device at this location, install the optical device bay filler panel shown below. This is required to maintain proper system cooling.
General Installation Process 13 Install Add-in Card Riser Assembly A B C D E Hooks (2) Slide back the card guide on the air duct. Pull up the blue plastic pin out of the card guide. B Slots (2) Position the riser card edge connector over the server board riser socket and align the two hooks on the back edge of the riser assembly with the slots on the back of the chassis, then press straight down into riser socket. Slide forward the card guide to lock in the back edge of the add-in card.
General Installation Process 18 A Install Second Power Supply Module (optional) Use the 'finger hole' to remove the filler panel. B Insert the power supply module into the power supply cage and push all the way until it clicks into place. Power Supply Removal: Pull out the module from the chassis by holding the handle and pressing the green latch in the direction shown. A B Finger Hole 19 20 Install Bezel (optional) NOTE: Before installing the bezel, you must install the rack handles.
General Installation Process 22 Software • BIOS, Drivers, and Operating System Installation A. Update the System Software: Update the System BIOS, ME Firmware, BMC Firmware, and FRU & SDR data, using the latest versions posted for this product at http://www.intel.com/support. NOTE: The FRUSDR utility must be run for full platform management functionality. B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller.
Reference Front Panel Controls and Indicators Standard Control Panel Your system may include one of two front control panel types.The features of each are as follows: A. ID Button with integrated LED B. NMI Button (recessed, tool required) C. LAN-1 Activity LED D. LAN-3 Activity LED E. System Cold Reset Button J I F. System Status LED G. Power Button with integrated LED H. HDD Activity LED I. LAN-4 Activity LED J.
Reference System Fan Connection Air F 1 FAN 1 FAN 2 FAN 3 FAN 4 FAN 5 A complete list of accessories and spares can be found at http://www.intel.com/support.
Reference System Cabling Diagram For system with 8 x 3.5” hard drive bay: NOTES: To activate the port SCU1 (4-7) on the server board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. A second SSD is supported when the optical drive is NOT in use. For cable routing, please refer to Page 14. Intel® Integrated RAID Module Power Supply SSD 2 8 x 3.
Reference System Cabling Diagram For system with 12 x 3.5” hard drive bay: 0 1 2 3 4 5 Installed into PCIe Riser Card Intel® Integrated RAID Module Intel® RAID Expander Card RES2SV240 Power Supply SSD SSD 2 Mount on Air Duct IC BBU Front Panel Server Board Interposer Board 12 x 3.
Reference System Cabling Diagram For system with 8 x 2.5” hard drive bay: NOTES: To activate the port SCU1 (4-7) on the server board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. A second SSD is supported when the optical drive is NOT in use. For cable routing, please refer to Page 17.
Reference System Cabling Diagram For system with 16 x 2.5” hard drive bay: NOTE: A second SSD is supported when the optical drive is NOT in use. For cable routing, please refer to Page 17. Intel® Integrated RAID Module Power Supply SSD 2 SAS Expander B C D 8 x 2.5" HSBP E Front Panel USB A Front Panel BBU Server Board Front Panel Video Mount on Air Duct IC F 8 x 2.
Reference System Cabling Diagram For system with 24 x 2.5” hard drive bay: NOTE: To activate the port SCU1 (4-7) on the server board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. Intel® Integrated RAID Module Power Supply SSD SSD 2 Mount on Air Duct IC A SAS Expander B G H C D 8 x 2.5" HSBP Front Panel BBU Server Board I E F Interposer Board 8 x 2.5" HSBP 2 8 x 2.
G31061-004