Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Cabling Guide for: Intel® C610 Series Chipset based Server Boards and Systems Intel® RAID Controller RS3WC080, RS3DC040, RS3DC080, RS3FC044, RS3UC080, RS25FB044, RS25AB080, RS25DB080, RS25NB008, RS25SB008, RCS25ZB040, RCS25ZB040LX Intel® Integrated RAID Module RMS3CC080, RMS3HC080, RMS3JC080, RMT3CB080, RMT3PB080, RMS25PB080, RMS25PB080N, RMS25PB040, RMS25CB080, RMS25CB040, RMS25KB080, RMS25
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Revision History Date Revision Number Modifications August, 2014 1.0 Initial release October, 2014 1.1 Updated chapter 1.1 Disclaimers Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Contents 1. Introduction ......................................................................................................................................................................................................... 1 2. Enclosure Cabling List .....................................................................................................................................................
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures 1. Introduction Chapter 2 introduces the cabling from server boards’ onboard RAID options, and from RAID controllers or integrated RAID modules to backplane with or without expander. Below tables give guidance on which cables to order for specific hardware configurations with selected server board, chassis, and backplane.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Boards 2 Cabling from On-board SATA Capable Controller Cabling from Mezzanine 12Gb/s Integrated RAID Module Cabling from Mezzanine 6Gb/s Integrated RAID Module Cabling from 12Gb/s RAID Controller1 n/a AXXCBL875HDHD AXXCBL875HDMS AXXCBL875HDHD n/a AXXCBL875HDHD AXXCBL875HDMS AXXCBL875HDHD Reuse cables supplied with system Reuse cables supplied with system AXXCBL730HDMS Reuse cables sup
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Boards Chassis Backplane Cabling from On-board SATA Capable Controller Cabling from Mezzanine 12Gb/s Integrated RAID Module Cabling from Mezzanine 6Gb/s Integrated RAID Module Cabling from 12Gb/s RAID Controller1 Cabling from 6Gb/s RAID Controller1 A2UREARHSDK Use cables in kit n/a n/a New cable from expander n/a A2U44X25NVME DK n/a n/a n/a n/a n/a Notes: 1.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures 2.2 Board Intel® Server Board S2600CW Product Family Cabling Drive Fixed or Types of Numbe hotDrives r& swap Supported2 Type Fixed SATA Only Drive kit required No additional parts needed. Expander required N/A 4x3.5” S2600CW Hot Swap 8x3.5” 8x2.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Board Drive Fixed or Types of Numbe hotDrives r& swap Supported2 Type S2600CW Hot Swap SATA + SAS Drive kit required FUP8X25S3HSDK (with SAS only HSBP FXX8X25S3HSBP) Up to 4x 2.5” NVMe 8x2.5” Hot drives, Up 1x to 8 Swap, FUP8X25S3NVDK NVMe SATA/SAS (with Combo support drives HSBP) (total 8 drives) 16x2.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures S2600CW Board Drive Fixed or Types of Numbe hotDrives r& swap Supported2 Type 16x2.5” Hot Swap SATA + SAS Drive kit required Expander required No expander (use onboard SATA and SAS controllers, 2X or use two FUP8X25S3HSDK 8 port HBAs.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Board Drive Fixed or Types of Numbe hotDrives r& swap Supported2 Type S2600CW SATA + SAS 16x2.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures 2.3 Cable Introduction Cable view Cable P/N AXXCBL950HDHD AXXCBL875HDHD AXXCBL800HDHD AXXCBL730HDHD Description 950mm long, cable kit (2 cables included), straight SFF8643 to straight SFF8643. Used in multiple systems as spare and/or accessory (1304, 2308, 2312). 875 mm long, cable kit (2 cables included), straight SFF8643 to straight SFF8643.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Cable view Cable P/N Description 950mm long, cable kit (2 cables included), straight SFF8643 to straight SFF8087. AXXCBL950HDMS Required in S2600WT 2U systems with 6Gb/s SAS integrated RAID module or 6Gb/s SAS RAID controller. (1304 with RAID controller, 2308 and 2312 with RAID controller/integrated RAID module). 875mm long, cable kit (2 cables included), straight SFF8643 to straight SFF8087.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Cable view Cable P/N AXXCBL1UHRHD AXXCBL450HD7S Description Combo cable kit, contains 2 cables: one is 730mm long and the other is 800mm long; right angle SFF8643 to straight SFF8643; spare cables used in 1U S2600WT systems to connect to onboard SATA ports. 2pcs 450mm, straight SFF8643 to 7 pin straight, used to replace cables shipped with pedestal 4U chassis. S2600CW spare kit.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures 3. Hot-Swap Backplane Overview Note: Before any cabling operation, refer to the respective integrated RAID module or RAID controller Tested Hardware and Operating System lists, in order to confirm the compatible Intel® Server Boards or Systems. Supported system/ chassis Backplane P/N Description Disk drive slot and cabling connector view (Two sides of backplane) 0-7: 8 x 3.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Supported system/ chassis Backplane P/N in chassis R2312XX XX and system R2312WT TYS Spare for 1U 8x2.5” chassis (R1208 family); Included in chassis R1208XX XX and system R1208WT TGS and R1208WT 2GS 12 Description Disk drive slot and cabling connector view (Two sides of backplane) A-C: 4-port SFF8643 connectors – Drives 8-11, 4-7, and 0-3 D: Power connectors E: SMBus connector 0-7: 8 x 2.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Supported system/ chassis Backplane P/N Description Disk drive slot and cabling connector view (Two sides of backplane) 0-3: 4 x 2.5'’ SATA/SAS drive slots 4-7: PCIe* SFF devices/ 4 x 2.5'’ SAS drive slots Spare for 1U 8x2.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Supported system/ chassis Spare for 1U 4x3.5” chassis (R1304 family); Included in chassis R1304XX XX and system R1304WT TGS and R1304WT 2GS Spare for 2U 8x2.5” cage (R2200 and P4000 families) 14 Backplane P/N Description Disk drive slot and cabling connector view (Two sides of backplane) 0-3: 4 x 3.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Supported system/ chassis Spare for R2200 system family or R2000 chassis family Backplane P/N Included in A2U8X25S3DPDK October, 2014 Description Disk drive slot and cabling connector view (Two sides of backplane) 0-7: 8 x 2.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Supported system/ chassis Spare for 2U or Pedestal systems 16 Backplane P/N Description Included in FUP8X25S3NVDK for Pedestal; Included in A2U44X25NVMEDK for 2U 0-7: 8 x 2.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Supported system/ chassis Backplane P/N Description Disk drive slot and cabling connector view (Two sides of backplane) 0-3: 4 x 3.
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Supported system/ chassis Backplane P/N Description Disk drive slot and cabling connector view (Two sides of backplane) TYS; A: SGPIO connector B: drive 1 C: Power connector D: HSBP I2C connector E: drive 0 Note: For more details of above backplanes, refer to Chapter 5.5 Storage Backplane Option in the Intel® Server System R1000WT Product Family Technical Product Specification, Chapter 6.