Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN Technical Product Specification Intel reference number G17455-008 Revision 2.
Revision History Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Revision History Date ii September 2010 Revision Number 0.1 Modifications Initial release. November 2010 0.5 Updated the hardware info. January 2011 0.7 Updated S1200BTS info. March 2011 1.0 Updated Regulatory info. May 2011 1.1 Updated Chassis Dimensions info. Updated Operation Temperature info. January 2012 2.0 Updated System Feature Set table. Added a note in chapter 1. October 2012 2.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Disclaimers Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT.
Table of Contents Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Table of Contents 1. Introduction ........................................................................................................................1 1.1 Chapter Outline ......................................................................................................1 1.2 Server Board Use Disclaimer .................................................................................2 2. Product Overview ...........
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Table of Contents 4.3 AC Inlet Connector ...............................................................................................20 4.3.1 AC Power Cord Specification Requirements ........................................................20 4.4 Marking and Identification ....................................................................................21 4.5 Efficiency...................................................................
List of Figures Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS List of Figures Figure 1. Intel® Server System R1304BTSSFAN/R1304BTLSFAN .............................................5 Figure 2. Intel® Server System R1304BTLSHBN ........................................................................5 Figure 3. Intel® Server System R1304BTSSFAN/R1304BTLSFAN Major System Components .. 6 Figure 4. Intel® Server System R1304BTLSHBN Major System Components .............................
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS List of Tables List of Tables Table 1. System Feature Set.......................................................................................................3 Table 2. Intel® Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN Dimensions5 Table 3. Input Voltage Range......................................................................................................9 Table 4. Intel® 250W PSU Cable Lengths ..............................
List of Tables Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS < This page intentionally left blank. > viii Revision 2.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 1. Introduction Introduction The Intel® Server Systems R1304BTSSFAN, R1304BTLSFAN, and R1304BTLSHBN are 1U server systems. The Intel® Server System R1304BTSSFAN supports up to four fixed Serial ATA (SATA) hard disk drives. The Intel® Server System R1304BTSSFAN includes the Intel® Server Board S1200BTS. The Intel® Server System R1304BTLSFAN supports up to four fixed Serial ATA (SATA) hard disk drives.
Introduction Glossary Reference Documents 1.2 Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Server Board Use Disclaimer Intel Corporation server boards contain a number of high-density VLSI (Very Large Scale Integration) and power delivery components that need adequate airflow to cool.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 2. Product Overview Product Overview The Intel® Server Systems R1304BTLSFAN and R1304BTLSHBN are both of 1U server system designed to support the Intel® Server Board S1200BTL. The Intel® Server System R1304BTSSFAN is 1U server system designed to support the Intel® Server Board S1200BTS. The Intel® Server Board S1200BTL, the Intel® Server Board S1200BTS, and the systems have features designed to support the entry-level market.
Product Overview Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Feature Description LAN - DB-9 serial Port A connector - Four USB ports on two USB/LAN combo connectors at the rear of the board - One USB 2x5 pin header, supporting two USB 2.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 2.1 Product Overview System Views Figure 1. Intel® Server System R1304BTSSFAN/R1304BTLSFAN Figure 2. Intel® Server System R1304BTLSHBN 2.2 Chassis Dimensions Table 2. Intel® Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN Dimensions Revision 2.4 Height 1.67 inches (4.24 centimeters) Width 17.25inches (43.82 centimeters) Depth 21.8 inches (55.
Product Overview 2.3 Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS System Components A Rack handles (two) F System Memory DIMM slots B Server Board G Cooling Fans C PCIe Riser Assembly H Front Panel D Processor and heatsink I Hard Drive Bays E Power supply J Front Panel Slimline optical drive Figure 3. Intel® Server System R1304BTSSFAN/R1304BTLSFAN Major System Components 6 Revision 2.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS A Rack handles (two) F System Memory DIMM slots B Server Board G Cooling Fans C PCIe Riser Assembly H Front Panel Board D Processor and Heatsink I Hard Drive Bays E Power supply J Slimline optical drive Product Overview Figure 4. Intel® Server System R1304BTLSHBN Major System Components The I/O connector locations on the back of the system are pre-cut, so an I/O shield is not required.
Product Overview 2.4 Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS System Boards The Intel® Server Systems R1304BTSSFAN, R1304BTLSFAN, and R1304BTLSHBN include system boards used as internal interconnects and provide feature accessibility. The following section provides a brief description for each. 2.4.1 Intel® Server System R1304BTSSFAN The Intel® Server System R1304BTSSFAN includes an Intel® Server Board S1200BTS. This board supports a PCI Express* riser card.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 3. 250W Power Subsystem 250W Power Subsystem The power subsystem of the server systems consists of a single, non-redundant 250-W power supply with five outputs: 3.3 V, 5 V, 12 V, -12 V, and 5 VSB. The form factor fits into a 1U system and provides a wire harness output to the system. An IEC connector is provided on the external face for AC input to the power supply. The power supply provides one non-redundant 40 mm fan for self-cooling.
250W Power Subsystem 3.1 Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Mechanical Specifications The 1U 250W power supply is designed specifically for use in the Intel® Server Systems R1304BTSSFAN and R1304BTLSFAN. The physical size of the power supply enclosure is intended to accommodate power ranges from 250 W. The power supply size is 40mm x 81.5mm x 150mm and has a wire harness for the DC outputs.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 3.2 250W Power Subsystem Output Connectors Listed or recognized component appliance wiring material (AVLV2), CN, rated min 80°C, 300 VDC (Volts Direct Current) should be used for all output wiring. Table 4.
250W Power Subsystem 3.2.2 Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Processor Power Connector (P2) Connector housing: 8-pin Molex* 39-01-2085 or equivalent. Contact: 44476-1111 or equivalent. Table 6. P2 Processor Power Connector 1 Pin Signal COM Black 5 Signal +12V Yellow 2 COM Black 6 +12V Yellow 3 COM Black 7 +12V Yellow 4 COM Black 8 +12V Yellow 3.2.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 3.3 250W Power Subsystem AC Inlet Connector The AC input connector should be an IEC 320 C-14 power inlet. This inlet is rated for 10A/250 VAC. 3.3.1 AC Power Cord Specification Requirements The AC power cord must meet the following specification requirements. Cable Type SJT Wire Size 16 AWG Temperature Rating 105ºC Amperage Rating 13 A Voltage Rating 125 V Figure 7. AC Power Cord Specifications 3.
250W Power Subsystem 3.7 Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Output Power/Currents The following table defines two power and current ratings for this 250-W power supply. The combined output power of all outputs should not exceed the rated output power. The power supply must meet both static and dynamic voltage regulation requirements for the minimum loading conditions. Table 10. Load Ratings Voltage +3.3 V 0.1 A Minimum 6A Maximum Output Power 19.8 W +5 V 0.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 250W Power Subsystem voltages are measured at the harness connectors. The voltage shall never exceed the maximum levels when measured at the power pins of the output harness connector during any single point of fail. The voltage shall never trip any lower than the minimum levels when measured at the power pins of the connector. Table 12. Over Voltage Protection (OVP) Limits 3.8.3 Output Voltage +3.3V 3.7 OVP MIN (V) 4.
350W Power Subsystem 4. Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 350W Power Subsystem The power subsystem of the server systems consists of a single, non-redundant 350-W power supply with five outputs: 3.3 V, 5 V, 12 V, -12 V, and 5 VSB. The form factor fits into a 1U system and provides a wire harness output to the system. An IEC connector is provided on the external face for AC input to the power supply. The power supply provides one non-redundant 40 mm fan for self-cooling.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 4.1 350W Power Subsystem Mechanical Specifications The 1U 350W power supply is designed specifically for use in the Intel® Server System R1304BTLSHBN. The physical size of the power supply enclosure is intended to accommodate power ranges from 350 W. The power supply size is 40mm x 81.5mm x 150mm and has a wire harness for the DC outputs.
350W Power Subsystem 4.2 Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Output Connectors Listed or recognized component appliance wiring material (AVLV2), CN, rated min 80°C, 300 VDC should be used for all output wiring. Table 14.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 4.2.2 350W Power Subsystem Processor Power Connector (P2) Connector housing: 8-pin Molex* 39-01-2085 or equivalent. Contact: 44476-1111 or equivalent. Table 16. P2 Processor Power Connector 1 Pin Signal COM Black 5 Signal +12V Yellow 2 COM Black 6 +12V Yellow 3 COM Black 7 +12V Yellow 4 COM Black 8 +12V Yellow 4.2.
350W Power Subsystem Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Table 19. AUX Power Connector 1 Pin Signal SCL 24 AWG Color White/Green 4 Signal COM 24 AWG Color White/Black 2 SDA White/Yellow 5 +3.3V White/Brown 3 N/C N/C 4.2.6 Pin Hot-swap Backplane Power Connector (P7) Connector housing: Molex* 39-01-2085 or equivalent. Contact: Molex* 39-00-0079 or equivalent. Table 20.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 4.4 350W Power Subsystem Marking and Identification The power supply module marking supports the following requirements: safety agency requirements, government requirements (if required, for example, point of manufacturing), power supply vendor requirements, and Intel manufacturing and field support requirements. 4.
350W Power Subsystem Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS OFF for 15sec min (with +5VSB/0.1A) and a PSON# cycle HIGH for 1sec shall be able to reset the power supply. 4.8.1 Over Current Protection (OCP) Each output shall have individual OCP protection circuits. The PSU shall shut down and latch off after an over current condition occurs. Whereas OCP of +5VSB shall turn the power supply into “hiccup mode” until the OCP condition removed.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 4.9 350W Power Subsystem PMBus* The PMBus* features included in this specification are requirements for ac/dc silver box power supply for use in server systems. This specification is based on the PMBus* Specifications Parts I and II, revision 1.1X3. 4.9.1 Related Documents PMBus* Power System Management Protocol Specification Part I – General Requirements, Transport and Electrical Interface, Revision 1.1X3.
Cooling Subsystem 5. Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Cooling Subsystem The Intel® Server System R1304BTSSFAN, R1304BTLSFAN, and R1304BTLSHBN cooling subsystem consists of three fans, a CPU air duct, and a PS/electronics bay isolation air baffle. These components provide the necessary cooling and airflow to the system. A fan on the processor heatsink is not needed.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 5.1 Cooling Subsystem Power Supply Fans The power supply supports one non-redundant 40 mm fan. It is responsible for the cooling of the power supply. 5.2 CPU Air Duct The chassis requires the use of a CPU air duct to direct airflow through the processor’s heatsink and memory area. Figure 12. Intel® Server System R1304BTSSFAN/R1304BTLSFAN Air Duct Figure 13. Intel® Server System R1304BTLSHBN Air Duct Revision 2.
Peripheral and Hard Drive Support 6. Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Peripheral and Hard Drive Support The Intel® Server System R1304BTSSFAN/R1304BTLSFAN provides support for four fixed hard drive bays and one slimline peripheral drive bay at the front of the chassis. The fixed hard drive bays are designed to support SATA drives only. A Slimline optical drive bay B Hard drive bays Figure 14.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 6.1 Peripheral and Hard Drive Support Optical Drive Support Both the fixed and hot-swap systems provide a slimline drive bay that you can configure for a SATA optical CD-ROM or DVD/CDR drive. The slimline devices are not hot-swappable. 6.1.1 Optical Drive Support The server systems support a slimline SATA optical drive. 6.2 Hard Disk Drive Support The Intel® Server System R1304BTSSFAN/R1304BTLSFAN supports up to four, 3.
Front Control Panel 7. Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Front Control Panel The standard control panel supports a power button, a status LED, a hard drive activity LED, and NIC 1 and NIC 2 activity LEDs. The control panel assembly comes pre-assembled into the chassis. The control panel assembly module slides into a predefined slot on the front of the chassis.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS LED System Status (on standby power) N/A N/A N/A Disk Activity Green Random blink HDD access Off Off No hard disk activity 7.1 Color Front Control Panel State Description Power/Sleep LED Table 28. SSI Power LED Operation State Power Off Power Mode Non-ACPI Off LED Description System power is off, and the BIOS has not initialized the chipset.
PCI Riser Cards and Assembly 8. Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS PCI Riser Cards and Assembly The Intel® Server System R1304BTSSFAN, R1304BTLSFAN, and R1304BTLSHBN provides one PCI Express* x8 slot that supports one riser card with one riser card slot. The riser card supports one low-profile PCI Express* x8 add-in card. Figure 17. PCIe Riser Card Assembly for the Intel® Server System R1304BTSSFAN, R1304BTLSFAN, and R1304BTLSHBN 30 Revision 2.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Intel® Server System R1304BTLSHBN Passive SAS/SATA Hot-swap Backplane 9. Intel® Server System R1304BTLSHBN Passive SAS/SATA Hot-swap Backplane The Intel® Server System R1304BTLSHBN supports a passive backplane designed to be compatible with the Intel® Server Board S1200BTL. The Intel® Server Board S1200BTL is connected directly to the SATA backplane (default) or you can connect the backplane to an add-in SAS or SATA adapter.
Intel® Server System R1304BTLSHBN Passive SAS/SATA Hot-swap Backplane Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Table 29. Passive SATA/SAS Backplane Power Connector Pin-out Pin # 1 Signal Name Ground 2 Ground 3 P5V 4 P5V 5 P12V 6 P12V 7 No Connection 8 P3V3 Table 30. Passive SATA/SAS Backplane Connector to Hard Drive Pin-out 9.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Supported Intel® Server Boards 10. Supported Intel® Server Boards The Intel® Server Systems R1304BTSSFAN, R1304BTLSFAN, and R1304BTLSHBN are mechanically and functionally designed to support the Intel® Server Board S1200BT family. For detailed server board information, refer to the Intel® Server Board S1200BT Technical Product Specification. Revision 2.
Environmental Specifications Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS 11. Environmental Specifications 11.1 System Level Environmental Limits The following table defines the system-level operating and non-operating environmental limits. Table 31.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips When adding or removing components or peripherals from the server board, AC power must be removed. With AC power plugged into the server board, 5-Volt standby is still present, even though the server board is powered off. When updating the BIOS and BMC, AC power must be on.
Appendix B: Integrated BMC Sensor Tables Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix B: Integrated BMC Sensor Tables The Intel® Server Board S1200BTL implements the following sensors: Sensor Type Codes The sensor table given below lists the sensor identification numbers and information regarding the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix B: Integrated BMC Sensor Tables Event Data Event data is the data that is included in an event message generated by the associated sensor. For threshold-based sensors, these abbreviations are used: - R: Reading value - T: Threshold value Rearm Sensors The rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states.
Appendix B: Integrated BMC Sensor Tables Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Table 32.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/Reading Type Appendix B: Integrated BMC Sensor Tables Event Offset Triggers Contrib.
Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Front Panel Temperature (Front Panel Temp) Sensor # Platform Applicability Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Sensor Type Event/Reading Type All Temperature 01h Threshold 01h All Temperature 01h Threshold 01h All Temperature 01h Threshold 01h Hot-swap Backplane Temperature 29h (HSBP Temp) All Temperature 01h Threshold 01h Fan Tachometer Sensors (Chassis specific sensor names) Chas
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Full Sensor Name (Sensor name in SDR) Power Supply 1 AC Power Input (PS1 Power In) Sensor # Platform Applicability Sensor Type Event/Reading Type 54h Chassisspecific Other Units 0Bh Threshold 01h 55h Chassisspecific Other Units 0Bh Threshold 01h 58h Chassisspecific Current 03h Threshold 01h 59h Chassisspecific Current 03h Threshold 01h 5Ch Chassisspecific Temperature 01h Threshold 01h Power Supply 2 Temperature (PS2 T
Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Sensor Type Event/Reading Type Event Offset Triggers Processor Thermal Control % (P1 Therm Ctrl %) 78h All Temperature 01h Threshold 01h Catastrophic Error (CATERR) 80h All Processor 07h Digital Discrete 01 – State Asserted 03h MSID Mismatch (MSID Mismatch) 81h All Processor 07h Processor Population Fault (CPU Mis
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Full Sensor Name (Sensor name in SDR) Baseboard +12V (BB +12.0V) Baseboard +5V (BB +5.0V) Baseboard +3.3V (BB +3.3V) Baseboard +5V Stand-by (BB +5.0V STBY) Baseboard +3.3V Auxiliary (BB +3.3V AUX) Baseboard +1.2V Processor Vccp (BB P1 Vccp) Baseboard +1.5V VDDQ (BB +1.5V P1 MEM) Baseboard CMOS Battery (BB +3.3V Vbat) Revision 2.
Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Baseboard Processor Vcc (BB P1 Vcc) Baseboard Processor VccUSA (BB P1 VccUSA) Baseboard +1.05V PCH (BB +1.05V PCH) Baseboard +1.05V Auxiliary (BB +1.05V AUX) Baseboard +1.35V VDDQ (BB +1.35V P1 MEM) Baseboard +12.0V V1 (BB +12.0V V1) Baseboard +1.5V Auxiliary (BB +1.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Full Sensor Name (Sensor name in SDR) Hard Disk Drive 1 Status (HDD 1 Status) Hard Disk Drive 2 Status (HDD 2 Status) Hard Disk Drive 3 Status (HDD 3 Status) Revision 2.
Appendix C: POST Code Diagnostic LED Decoder Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix C: POST Code Diagnostic LED Decoder During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix C: POST Code Diagnostic LED Decoder Progress Code 0x0F Diagnostic LED Decoder O = On, X=Off Upper Nibble Lower Nibble MSB 8h 4h 2h 1h 8h 4h 2h 1h LSB #7 #6 #5 #4 #3 #2 #1 #0 X X X X O O O O 0x10 X X X O PEI Phase X X X X PEI Core Starts 0x11 X X X O X X X O CPU PEI Module Starts 0x15 X X X O X O X O North Bridge PEI Module Starts 0x19 X X X O O X X O South Bridge PEI Module Starts 0x31 X X O O X X X O Memory Ins
Appendix C: POST Code Diagnostic LED Decoder Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Progress Code 0xA3 Diagnostic LED Decoder O = On, X=Off Upper Nibble Lower Nibble MSB 8h 4h 2h 1h 8h 4h 2h 1h LSB #7 #6 #5 #4 #3 #2 #1 #0 O X O X X X O O DXE IDE detect 0xA4 O X O X X O X X DXE IDE enable 0xA9 O X O X O X X O DXE verifying SETUP password 0xAB O X O X O X O O DXE SETUP start 0xAC O X O X O O X X DXE SETUP input wait 0xAD O X O X O O X O DXE Ready to Boot 0xAE
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix D: POST Error Beep Codes Appendix D: POST Error Beep Codes The following table lists POST error beep codes. Prior to system video initialization, the BIOS uses these beep codes to inform users of error conditions. The beep code is followed by a user-visible code on POST Progress LEDs. Table 35.
Appendix D: POST Error Beep Codes Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Error Code A100 BIOS ACM Error Error Message Response Major A421 PCI component encountered a SERR error Fatal A5A0 PCI Express* component encountered a PERR error Minor A5A1 PCI Express* component encountered a SERR error Fatal POST Error Beep Codes The following table lists POST error beep codes.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Glossary Glossary This section contains important terms used in the preceding chapters. For ease of use, numeric entries are listed first (for example, 82460GX) with alpha entries following (for example, AGP 4x). Acronyms are then entered in their respective place, with non-acronyms following.
Glossary Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Term Hz 2 52 Definition Hertz (1 cycle/second) IC Inter-Integrated Circuit Bus IA Intel Architecture IBF Input Buffer ICH I/O Controller Hub ICMB Intelligent Chassis Management Bus IERR Internal Error IFB I/O and Firmware Bridge ILM Independent Loading Mechanism IMC Integrated Memory Controller INTR Interrupt I/OAT I/O Acceleration Technology IOH I/O Hub IP Internet Protocol IPMB Intelligent Platform M
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Term Definition PEP Platform Event Paging PIA Platform Information Area (This feature configures the firmware for the platform hardware) PLD Programmable Logic Device PMI Platform Management Interrupt POST Power-On Self Test PSMI Power Supply Management Interface PWM Pulse-Width Modulation QPI QuickPath Interconnect RAM Random Access Memory RASUM Reliability, Availability, Serviceability, Usability, and Manageability RIS
Glossary Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Term ZIF 54 Definition Zero Insertion Force Revision 2.
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Reference Documents Reference Documents Refer to the following documents for additional information: Intel® Server Board S1200BT BIOS External Product Specification Intel® Server Board S1200BT Common Core Integrated BMC External Product Specification Revision 2.