Quick Start Guide Back

16
Software
• BIOS, Drivers, and Operating System Installation
A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS
Setup Utility to determine the installed BIOS version. Compare this to the versions at:
http://www.intel.com/support/motherboards/server.
If new versions are available, update the BIOS on your server. See the Techinical Product Specification
on the Intel
®
Server Deployment Toolkit CD for update instructions.
B. Configure your RAID Controller:
Use the instructions provided with the RAID controller.
C. Install your Operating System:
Use the instructions provided with the RAID controller
and with the operating system.
D. Install Operating System Drivers: With the operating system running, insert the
Intel
®
Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel
®
Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other
operating systems, browse the CD folders to locate and install the driver files.
Side 2
9
Install Optical
Drive and
Hard Drive(s)
See the documentation that came
with your server chassis for drive
installation.
14
Install Add-in
Card[s]
See the documentation that came with your
server chassis for add-in card installation.
For the Intel
®
Server Chassis P4000 series,
see the Quick Start User's Guide
accompanying the chassis.
15
Finishing Up
Before installing your operating system, you must finish your chassis
installation, make I/O connections and plug in AC power.
See your chassis documentation for AC power and grounding requirements.
CAUTION: See your chassis
documentation for AC power and
grounding requirements.
Network
USB
0-1
USB
2-3
NIC1
10/100/
1000 Mb
NIC2
10/100/
1000 Mb
Video
Serial A
Common Problems and Solutions
The system does not boot or show video at power-on.
Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power.
Only Intel
®
Xeon
®
E3-1200 processors, the 2
nd
Generation Intel
®
Core™ i3 processors, Intel
®
Xeon
®
E3-1200 V2 processors or the 3
rd
Generation Intel
®
Core™ i3 processors
with 95W and
less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel
®
Xeon
®
processors are not supported.
Beep code 1-5-2-1 in a system means you do not have the supported processor installed.
The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that indicates memory errors in early POST.
Remember, all DIMMs must be:
DDR3 1066/1333/1600 MHz UDIMM.
From the same manufacturer.
Installed beginning with DIMM A1.
For a list of hardware components that have been tested with this system, see:
http://www.intel.com/support/motherboards/server.
11
Attach Intrusion Switch Cable
Note: For a non-Intel chassis, see your chassis
documentation for intrusion switch requirements.
Server
Board
Server
Board
Intrusion
Switch
Connector
IMPORTANT NOTE:
Return to your Intel
®
Server
Chassis Quick Start User's
Guide, or your non-Intel
®
chassis documentation to
finish installation and
configuration of your Intel
®
Server Board S1200BTS.
Return to this document to
finish up, including software,
BIOS, drivers and operating
system installation.
12
Attach Front Panel, Serial, and USB Connections
Note: For a non-Intel
®
chassis,
see your chassis documentation
for front panel features and server
board connection requirements.
Internal
USB/Serial
Connector
Detail
Serial B
USB
Front Panel
USB Floppy
USB
Connector
Detail
13
Chassis Fan Connections
For a non-Intel
®
server chassis, see the "Making Connections ... Quick Reference"
section below, and the documentation accompanying your chassis for specific
chassis fan connection requirements.
Attach fans
with 4-pin
connectors
here.
Server
Board
7
Install DIMM Memory Modules
To Install DIMMs:
DDR3 DIMM Memory Identification:
Open both DIMM socket levers.
Push down firmly on the DIMM until it
snaps into place and both levers close.
Insert DIMM making sure the connector edge
of the DIMM aligns correctly with the slot.
C
A
D
IMPORTANT! Visually check that each
latch is fully closed and correctly
engaged with each DIMM edge slot.
E
Note location of alignment notch.
B
CAUTION: Avoid touching contacts when
handling or installing DIMMs.
DIMM
notch and
socket
bump must
align as
shown.
Other
Memory
DDR3
This server board supports up to 4 DDR3 1066/1333/1600
ECC UDIMM.
CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures
to avoid possible damage to system components.
Memory Configurations and Population Order:
Memory Type: Minimum of one 1 GB, DDR3 1066/1333/1600 MHz ECC UDIMM.
A
C
D
B
E
Note: For additional memory configurations, see the Intel
®
Server Board S1200BTS
Techinical Product Specification at:
http://www.intel.com/support/motherboards/server.
Memory sizing and configuration is supported only for qualified DIMMs approved by
Intel
®
. For a list of supported memory, see the tested memory list at
http://serverconfigurator.intel.com/default.aspx
DIMM A2
DIMM A1
DIMM B2
DIMM B1
Intel
®
Server Board S1200BTS
Component Layout
Note: Not all
components, jumpers
and connectors are
described in this
diagram. Refer to
your Server Board
Technical Product
Specification on the
Intel
®
Server
Deployment Toolkit
CD for additional
information.
SATA 5
SATA 2
SATA 1
SATA 0
USB 4-5
Front Panel
Connector
SATA 4
SATA 3
SATA_SGPIO
SYS FAN_3
SYS FAN_1
Processor Socket
CPU Fan
Connector
CMOS battery
HDD LED
TPM
SATA Key
Chassis Intrusion
CPU Power
Connector
Diagnostic
LEDs
SYS FAN_2
Note: Refer to the Technical Product Specification
for Diagnostic LED decoder list.
Slot 4 ( PCI )
3
2
Default
Recover
J2G1
BIOS
Recovery
3
2
Default
Clear
J1H3
CMOS
Clear
3
2
Default
J1G1
Password
Clear
Cleared
3
2
Default
J2J1
Enabled
ME
Force
Update
Serial-A
VGA
NIC2
USB2
USB3
NIC1
USB0
USB1
Main Power
Connector
DIMM_A2
DIMM_A1
DIMM_B2
DIMM_B1
Slot 6 ( PCIe x 8 ) LP Riser
Slot 5 ( PCIe x 4 )
Slot 7 ( PCIe x 8 )
USB 6
2
Reset Button
NIC 2
Link/Act
NIC 1
Link/Act
Power Button
HDD LED
Power LED
Front Panel Header
(J1C1)
Document/Tool
Available Documents
Technical Product Specification
Monthly Specification Update
Spares, Parts List, and Configuration Guide
Sever Configurator Tool
Software and Drivers
Content
In-depth technical information
Technical information and issues update
Supported accessories and spares list
Tested peripherals and operating systems list
Tested memory list
Supported processors list
Up-to-date firmware, driver and utility information
Additional Reference documents available at:
http://www.intel.com/support/motherboards/server.
A complete list of accessories and spares can be found at:
http://www.intel.com/support/motherboards/server
(search for the document titled “Spares and Configuration Guide”.)
Accessories and Order Codes
Intel
®
Integrated RAID Module
Intel
®
Integrated RAID Module
Intel
®
Trusted Platform Module
AXXTPME3
AXXRMS2AF040
AXXRMS2LL040
Additional Reference documents available at:
http://www.intel.com/support/motherboards/server
ATX I/O Shield AXXTIO
SATA Slim-Line DVD
AXXSATADVDROM
Making Connections to the Server Board ... Quick Reference
=
Make this connection
=
Make this connection
D. System Fan 1 Header
E. System Fan 2 Header
F. System Fan 3 Header
Intel
®
Server Chassis
P4000 series
CPU/System Fan Connections
A. +12V CPU Power Connector
B. Main Power Connector
C. Front Panel Header
Required Connections
Intel
®
Server Chassis
P4000 series
=
Make this connection
Optional Connections
H. USB 4-6
I. SATA Connectors
J. SATA SGPIO
K. TPM
L. SATA Key
M. Chassis Intrusion Header
Intel
®
Server Chassis
P4000 series
G. CPU Fan Header
IMPORTANT Note:
Cables should be
tied for better airflow.
Use cable-ties as necessary.
C
Front Panel
Serial ATA
I
USB
H
6
4-5
Main Power
12V CPU Power
A
Intrusion
M
SATA Key
L
SATA SGPIO
J
TPM
K
B
CPU Fan
G
E
Sys Fan 3
D
Sys Fan 1
F
Sys Fan 2
Note: For a non-Intel Chassis, see your chassis
documentation for server board connection information.
Note: Not all optional connections are shown in this
diagram. Refer to your Server Board Service Guide, and
your server chassis documentation for additional
connection information.
8
Make Server
Board Power
Connections
Attach the CPU power connector.
Attach the main power connector.
IMPORTANT NOTE:
If you are using a non-Intel server chassis
with an ATX power supply, see the documentation that came
with your chassis for installation information.
CAUTION:
Note the location of the
latch on each power cable
connector and align it with the matching
tab on each server board socket.
Main Power
Connector Detail
B
Latch
Tab
CPU Power
Connector Detail
A
A
B
10
Connect Hard Drives/Optical
Drive to Server Board
Connect SATA Data Cables
to server board here.
Begin cable connections
at the SATA 0 location.
SATA Data
Cable Connector
Server
Board
0
4
2
Server
Board
1
5
3

Summary of content (1 pages)