Server WHQL Testing Services Enterprise Platforms and Services Division Intel® Server System S7000FC4URE-IR Server Test Submission (STS) Report For the Microsoft® Windows® Logo Program (WLP) Rev 2.0 June 24, 2008 ® This report describes the Intel S7000FC4UR Server System Windows* Logo Program test run conducted by Intel Enterprise Platforms and Services Division (EPSD).
Revision History and Disclaimers S7000FC4URE-IR-IR Revision History and Disclaimers Revision History Revision Date Comments 1.0 8/29/2007 Internal version of the STS Report for Windows Server 2003 Submission for Intel Server System S7000FC4UR (64-bit only) 1.1 9/5/2007 STS Report for Windows Server 2003 Submission for Intel Server System S7000FC4UR (32-bit and 64-bit ) 1.
S7000FC4URE-IR-IR Contents Contents Revision History and Disclaimers ..................................................................... 2 Introduction ......................................................................................................... 4 Overview of Contents.............................................................................................................. 4 Terms and Definitions .............................................................................................
Introduction S7000FC4URE-IR-IR Introduction This report provides an overview of the testing conducted on the Intel® Server System S7000FC4URE by Intel EPSD and provides details about this testing run. Overview of Contents Section Content Introduction Brief descriptions of the sections in the report. Table listing terms and definitions.
S7000FC4URE-IR-IR Server System Submission Information Server System Submission Information Intel Server System Submission Report: Completion of WLP Data in this section reflects system submission information at the time of WLP Update submission.
Server System Submission Information S7000FC4URE-IR-IR Server Board Configuration Information Processor Quantity 4 (physical processors installed) Front Side Bus Speed 1067 MHz Family/Model Quad-Core Intel® Xeon® Processors 7300 Series or Dual-Core Intel Xeon Processors 7200 Series Speed 1.60, 1.86, 2.13, 2.40, and 2.
S7000FC4URE-IR-IR Server System Submission Information Bus Types Check all that Apply 5 PS/2 Check all that Apply AGP* 1394 PCCard* (16-bit) CF (Compact Flash) CardBus* (32-bit) 5 PCI USB Mini-PCI USB 2.
Server System Submission Information S7000FC4URE-IR-IR Windows Server 2008 – 32Bit 1.2.79.9 (Pkg 12.4) Windows Server 2008 – 64Bit 1.2.79.9 (Pkg 12.4) Windows Server 2008 – 32Bit 8.24.3.0 Windows Server 2008 – 64Bit 8.24.3.0 Windows Server 2008 – 32Bit 1.0.4.0015 Windows Server 2008 – 64Bit 1.0.4.0015 Intel® ESG-SHV backplane Windows Server 2008 – 32Bit 5.00.6055.2 (Null driver) Windows Server 2008 – 64Bit 5.00.6055.
S7000FC4URE-IR-IR Hardware Compatibility Tests Used Hardware Compatibility Tests Used Microsoft* Windows Hardware Driver Central Server Testing Home Page: http://www.microsoft.com/whdc/hwtest/system/default.mspx. Please check this website regularly for test kit updates. Operating Systems Notes Hardware Compatibility Tests (HCT) Windows Server 2008 DTM 1.2 Test Procedures and Readme files for Windows XP SP2, Windows vista, Windows Server 2003, and Windows Server 2008 (4.95MB) DTM 1.
Errata and Contingencies S7000FC4URE-IR-IR Errata and Contingencies Microsoft* System DTM Errata list is available at: http://www.microsoft.com/whdc/hwtest/search/results.
S7000FC4URE-IR-IR Errata and Contingencies Testing Exceptions for S7000FC4URE-IR Windows Server 2008 Data in this section reflects product data and test exceptions listed in section 2 of the S7000FC4URE-IR Readme file at time of WLP First-Time submission ID Number 1296878. Failure type (Contingency, Errata, Incident) ID number (Windows XP, Windows 2000, etc.
Errata and Contingencies Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) S7000FC4URE-IR-IR Assertion 4BA8F23A-6BB1-48EE-88D8-ED1A3ECD34B9 SSVID register of the Subsystem ID and Subsystem Vendor ID Capability table must be read-only . Assertion 6B0F606E-DBB3-4B8C-887932B302412EB8 SSID register of the Subsystem ID and Subsystem Vendor ID Capability table must be read-only .
S7000FC4URE-IR-IR Errata and Contingencies Windows Server 2008 Errata 1113 Failing test name PCI Harware Compliance Test for Systems Running Windows Vista (PCIHCT) Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) Bit 5 (Retrain Link) in the Link Control register (offset 10h) in the PCI Express Capability table must always return 0 on reads even though it is read-write.
Errata and Contingencies Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) S7000FC4URE-IR-IR PCI Compliance - Bit 3 (Read Completion Boundary) in the Link Control register (offset 10h) in the PCI Express Capability table must be read-only and always return 0 for switch ports.
S7000FC4URE-IR-IR Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) Errata and Contingencies Assertion 7A5587BC-5646-4DC4-9A5D-22F85AB2204E: FAILED. PCI Express ports and bridges must implement Subsystem ID and Subsystem Vendor ID Capability.
Errata and Contingencies Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) S7000FC4URE-IR-IR According to the PCI Express Base Specification, Rev 2.0 Section 7.8.8, this bit field is undefined when the link is not up. If there is not PCIe device behind the bridge, then the link can NOT be up and therefore the field is undefined. Bit 13 in the same register (Link Status) can be used to determine if the link is active (up).
S7000FC4URE-IR-IR Errata and Contingencies Additional information (for example, test system in a multiple system configuration) Failure type (Contingency, Errata, Incident) ID number Windows Server 2008 Errata 563 Failing test name Signed Driver Check Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) Chklogo6 may fail when the device under test uses muiltiple drivers ERROR: Test was unable to match this device ID with the device ID of the
Errata and Contingencies S7000FC4URE-IR-IR Additional information (for example, test system in a multiple system configuration) Failure type (Contingency, Errata, Incident) ID number (Windows XP, Windows 2000, etc.
S7000FC4URE-IR-IR Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) Errata and Contingencies Bit 10 (Interrupt Disable) in the Command register (offset 4h) in the Header table must be read-writable if the device supports an interrupt. Additional information (for example, test system in a multiple system configuration) Failure type (Contingency, Errata, Incident) ID number (Windows XP, Windows 2000, etc.
Errata and Contingencies S7000FC4URE-IR-IR Additional information (for example, test system in a multiple system configuration) Failure type (Contingency, Errata, Incident) ID number (Windows XP, Windows 2000, etc.
S7000FC4URE-IR-IR Errata and Contingencies Failure type (Contingency, Errata, Incident) ID number (Windows XP, Windows 2000, etc.) Windows Server 2008 x64 Errata 566 Failing test name PCI Hardware Compliance Test Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) Assertion 7A5587BC-5646-4DC4-9A5D-22F85AB2204E: FAILED. PCI Express ports and bridges must implement Subsystem ID and Subsystem Vendor ID Capability.
Errata and Contingencies S7000FC4URE-IR-IR Additional information (for example, test system in a multiple system configuration) Failure type (Contingency, Errata, Incident) ID number Windows Server 2008 x64 Errata 1141 Failing test name PCI Hardware Compliance Test Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) Assertion 5FC5B29C-0F24-423B-856A-87C9E31C6802 Bit 14 (Completion Timeout Mask) in the Uncorrectable Error Mask register (offs
S7000FC4URE-IR-IR Applicable error message (Type N/A if the error message or failing text is excessive or if there is no text) Errata and Contingencies Chklogo6 may fail when the device under test uses muiltiple drivers ERROR: Test was unable to match this device ID with the device ID of the device for which Error: this driver file was tested with this driver file was tested with.
Appendix A – Submission History S7000FC4URE-IR-IR Appendix A – Submission History ® Microsoft “Designed for Windows*” logo submission history for the Intel Server S7000FC4URE-IR: Submission ID Type Date OS Qualified Processor Speeds Board Revision BIOS Version 1260857 First-Time 8/17/2007 Windows Server 2003 EE SP2 64bit 1.60, 1.86, 2.00, 2.33, 2.66, 3.00, 3.20, and 3.73 GHz 501 SFC4UR.86B.01.00.