Technical Advisory 951

This Technical Advisory describes an issue which may or may not affect the customer’s product
Intel Technical Advisory TA-0951-2
5200 NE Elam Young Parkway
Hillsboro, OR 97124
Aug 9, 2010
Copyright © 2010 Intel Corporation. * Other names and brands may be claimed as the property of others.
FRUSDR may not be updated properly with BMC00.48 or BMC00.49
installed
Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise,
to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such
products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of
Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent,
copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining
applications. Intel may make changes to specifications and product descriptions at any time, without notice. The Intel products
described herein may contain design defects or errors known as errata which may cause the product to deviate from published
specifications. Current characterized errata are available on request.
Products Affected
S5520UR S5520HC
SR1600UR S5520HCT
SR1600URHS S5500HCV
SR1625UR S5520SC
SR1625URSAS SC5650HCBRP
SR2600URBRP SC5650SCWS
SR2600URLX S5500BC
SR2625URBRP SR1630BC
SR2625URBRP SC5650BCDP
SR2625URLX SR2612UR
SR2625URSAS
S5500WB
SR2600URSATA
SR1690WB
Description
With BMC (Baseboard Management Controller) version 00.48 and 00.49 installed on the above products, Intel has
identified a rare possibility that the system FRUSDR fails to get updated properly. This occurs when an attempt is made
to update the FRUSDR.
The following error message may display if UEFI shell interface is used to update FRUSDR: “ERROR: Invalid base
board product ID ‘0’ detected”. If Intel
®
Deployment Assistant is used to update FRUSDR, the following error message
may display: “Error string not found”.
Specifically to the Intel
®
Server Board S5500WB and Intel
®
Server System SR1690WB only, when this issue happens,
the following false error messages may be flagged, including incorrect SDR sensor reading (no reading on BB +1.1V P2
Vccp, BB +1.5V P2 DDR3, P2 Thermal Margin, P2 Thermal Ctrl% and not readable on P1 VRD Hot and P2 VRD Hot),
unexpected CPU missing SEL event and System Status LED be lit yellow unexpectedly.

Summary of content (2 pages)