Slimline USB Floppy/CD-ROM/DVD-ROM Drive Kit Install Guide: Intel® Server Chassis SC5400 Intel® Entry Server Chassis SC5299-E A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Intel Order Number: D51604-002
Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen.
Safety Information Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
Contents Contents Safety Information ..................................................................................................... iii Important Safety Instructions ................................................................................................ iii Wichtige Sicherheitshinweise ............................................................................................... iii Consignes de sécurité ......................................................................................
Contents vi Slimline USB Floppy/CD-ROM/DVD-ROM Drive Kit Install Guide
List of Figures List of Figures Figure 1. Removing Drive Cage from Drive Bay ........................................................................ 3 Figure 2. Removing Cage Top from Drive Cage ........................................................................ 4 Figure 3. Inserting Slimline Floppy Drive into Drive Cage.......................................................... 5 Figure 4. Securing Slimline Floppy Drive to Drive Cage ............................................................
List of Figures viii Slimline USB Floppy/CD-ROM/DVD-ROM Drive Kit Install Guide
1 Installation Information This Slimline USB Floppy/CD-ROM/DVD-ROM Drive Kit supports the following slimline drives in the Intel® Server Chassis SC5400 or Intel® Entry Server Chassis SC5299-E: • A USB slimline floppy drive AND • A slimline CD-ROM drive OR slimline DVD-ROM drive This accessory kit is required to connect a slimline floppy drive, slimline CD-ROM drive or slimline DVD-ROM drive to the server board. Note: You can install either a slimline CD-ROM drive OR a slimline DVD-ROM drive.
Installation Information — Fastener “FDU” Note: Slimline floppy drives, slimline CD-ROM drives and/or slimline DVD-ROM drives are not included with this kit. For a list of supported drives for the Intel® Server Chassis SC5400, see http://support.intel.com/support/motherboards/server/chassis/SC5400. For a list of supported drives for the Intel® Entry Server Chassis SC5299-E, see http:// support.intel.com/support/motherboards/server/chassis/SC5299-E.
Installation Information 4. Lift the drive cage up and out of the drive bay. B A AF000486 Figure 1.
Installation Information Remove Cage Top from Drive Cage 1. Face the front of the drive cage. 2. Pull out slightly on the rolled lip at the left side of the cage top. 3. Disengage the cage top from the tabs at the left side (see letter “A” in the following figure). 4. Lift the left side of the cage top. 5. Disengage the cage top from the tabs on the right side of the drive cage. 6. Remove the cage top (see letter “B”). A B AF000492 Figure 2.
Installation Information Install Slimline USB Floppy Drive 1. Insert the slimline floppy drive into the bottom tray of the drive cage. AF000494 Figure 3. Inserting Slimline Floppy Drive into Drive Cage 2. Line up the screw holes on the left and right sides of the slimline floppy drive with the corresponding holes in the drive cage (see letter “A” in the following figure). The front of the slimline floppy drive will extend slightly out from the front of the drive cage. 3.
Installation Information Install Slimline CD-ROM or DVD-ROM Drive Note: You can install either a slimline CD-ROM drive OR a slimline DVD-ROM drive.You cannot install both. Note: For Intel supplied CD-ROM/DVD-ROM drives, the correct setting is “No Jumper”. Note: For non-Intel supplied CD-ROM/DVD-ROM drives, see the documentation that came with your slimline drive for master/slave jumper settings. 1. Turn the drive cage so that the metal flange at the side of the drive extends to the right. 2.
Installation Information 5. Line up the screw holes on the left and right sides of the slimline CD-ROM/DVDROM drive with the corresponding screws on the drive cage (see letter “A” in the following figure). The front of the slimline drive will extend slightly from the front of the drive cage. 6. Use four screws from the bag marked “CD” to attach the drive to each side of the drive cage (two screws on each side). A A AF000487 Figure 6.
Installation Information Re-install Cage Top on Drive Cage 1. Hold the cage top (see letter “A” in the following figure) at a downward angle toward the drive cage. 2. Engage the slots at the right side of the cage top to the tabs at drive cage base (see letter “B”). 3. Rotate the cage top downward at the left side to engage the left tabs (see letter “C”). C A C B AF000488 Figure 7.
Installation Information Insert Drive Cage into Drive Bay 1. Insert the front of the device cage into the drive bay then lower the back of the drive cage (see letter “A” in the following figure). When properly positioned, the front of the cage will be flush and the screw holes in the drive cage will match the screw holes in the bottom of the drive bay. 2. Use two screws to secure the drive cage to the drive bay (see letter “B”). A B AF000489 Figure 8. Inserting Drive Cage into Drive Bay 3.
Installation Information the Slimline Drive Assembly into an Intel® Entry Server Chassis SC5299-E” on page 16. Installing the Slimline Drive Assembly into an Intel® Server Chassis SC5400 Note: This section only applies to installing the slimline drive assembly into an Intel® Server Chassis SC5400.
Installation Information Remove Bezel Assembly The bezel assembly consists of two parts, an inner bezel door and an outer bezel door. Both parts comprise the bezel assembly in the pedestal configuration. In the rack configuration, only the inner bezel door is used. To remove the bezel assembly: 1. Release the two plastic tabs (see letter “A” in the following figure) on the left side of the bezel assembly to disengage the tabs. 2. Rotate the bezel assembly (see letter “B”) no more than 40 degrees outward.
Installation Information Remove EMI Shield/Slide Assembly 1. Press in on the side latches (see letter “A” in the following figure) to remove the EMI shield/slide assembly from the upper device bay. A A AF000634 Figure 11. Removing EMI Shield/Slide Assembly from Intel® Server Chassis SC5400 Attach Drive Rails to Slimline Drive Assembly 1. Attach the drive rails to the slimline drive assembly using the top set of holes. AF000485 Figure 12.
Installation Information Insert Slimline Drive Assembly into Server Chassis 1. Slide the slimline drive assembly into the server chassis. 2. Make sure that the drive rails are using the correct slots in the chassis. A AF000633 Figure 13. Inserting Slimline Drive Assembly into Intel® Server Chassis SC5400 Make Cable Connections 1. Connect the IDE cable (see letter “A” in the following figure) from the chassis to the slimline drive backplane. 2.
Installation Information Re-install Bezel Assembly Note: Both the outer bezel door and inner bezel door are used when the chassis is configured for the pedestal position. For rack-configured systems, only the inner bezel door is used. 1. For a pedestal-configured system, open the outer bezel door of the bezel assembly (see letter “A” in the following figure). 2.
Installation Information Re-install Chassis Cover 1. Replace the chassis cover. 2. Slide the chassis cover forward. 3. (Optional) Secure the chassis cover to the chassis with screw (see letter “A” in the following figure). A A AF000572 Figure 16. Re-installing Chassis Cover on Intel® Server Chassis SC5400 4. Reconnect all peripheral devices and the AC power cord. 5. Power up the system.
Installation Information Installing the Slimline Drive Assembly into an Intel® Entry Server Chassis SC5299-E Note: This section only applies to installing the slimline drive assembly into an Intel® Entry Server Chassis SC5299-E. If you are installing the slimline drive assembly into an Intel® Server Chassis SC5400, follow the instructions under “Installing the Slimline Drive Assembly into an Intel® Entry Server Chassis SC5299-E” on page 16. Remove Chassis Cover 1. Unplug all power cables from the chassis.
Installation Information Remove Bezel Assembly 1. Disengage the two bezel tabs from the left side of the chassis (see letter “A” in the following figure). 2. Rotate the left side of the bezel assembly outward slightly (see letter “B”). 3. Disengage the three clips that attach the right side of the bezel assembly to the chassis (see letter “C”) and remove chassis cover. C A C C A B TP02034 Figure 18. Removing Bezel Assembly from Intel® Entry Server Chassis SC5299-E Remove EMI Shield 1.
Installation Information Insert Slimline Drive Assembly into Chassis 1. Move latch to the “unlock” position (see letter “A” in the following figure). A AF000636 Figure 20. Unlocking Device Bay Latch on Intel® Entry Server Chassis SC5299-E 2. Insert slimline drive assembly into the 5.25-in drive bay opening in the chassis (see letter “A” in the following figure). 3. Line up holes in slimline drive assembly with holes in chassis (see letter “B”). 4. Move latch to the “lock” position (see letter “C”).
Installation Information Make Cable Connections 1. Connect the IDE cable (see letter “A” in the following figure) from the chassis to the slimline drive backplane. 2. Connect the power adapter cable (see letter “B”) from a power connection to the slimline drive backplane. 3. Connect the USB cable (see letter “C”) from the server board to the slimline drive backplane. A B C AF000491 Figure 22.
Installation Information Re-install Bezel Assembly 1. Remove filler panel from the bezel assembly that corresponds with the position of the installed slimline drive assembly. TP01723 Figure 23. Removing Filler Panel from Bezel Assembly of Intel® Entry Server Chassis SC5299-E 2. Line up the three clips on the right side of the bezel assembly with the corresponding slots on the right side of the chassis (see letter “A” in the following figure). 3. Engage the clips with the slots (see letter “B”). 4.
Installation Information Re-install Chassis Cover 1. Slide the chassis cover on the chassis and latch securely (see letter “A” in the following figure). 2. (Optional) Secure the chassis cover to the chassis with screw (see letter “B” in the following figure). B A B TP00831 Figure 25. Re-installing Chassis Cover on Intel® Entry Server Chassis SC5299-E 3. Reconnect all peripheral devices and the AC power cord. 4.