Quick Start Guide Back

Side 2
24
Replace Side Cover
Re-install side cover and latch securely.
Side Cover
CAUTION: This chassis must be
operated with the SIDE COVERS
installed to ensure proper cooling.
14
Install Hard Drives into Fixed Drive Bay
A. Open Cage Access Doors B. Remove Device Slides
C. Install Slides to Hard Drive
Note: Device slides are
"tool-less". Insert slide
tabs into hard drive
mounting holes and
press firmly into place.
D. Insert Drive/Slide Assembly
into Cage
Note: Make sure connector end of drive
faces toward the rear of the cage.
Rear
of Cage
Loosen the
captive thumb
screw, then
open the
upper door.
Open the
lower door.
Connector
end of drive
to back.
Ta b
Close cage doors and tighten captive
thrumb screw. Repeat this procedure
for each drive.
Front Panel Controls
and Indicators
A. ID Button
B. System Reset
Button
C. NIC1 LED
D. System Power
Button
E. Hard Drive
Activity LED
F. System ON
LED
G. NIC2 LED
H. ID LED
I. Status LED
J. NMI Button
A
B
C
D
E
F
G
H
I
J
Reference
22
Rackmount
Conguration
(optional)
If you intend to configure
your server as a pedestal
system, disregard this
step.
If you intend to configure
your server as a rack
mount system, go to the
instructions that came
with your rack mount kit
to complete your server
assembly.
19
Memory Air Bae
Conguration
This memory air baffle is REQUIRED for all
Intel
®
Server Boards currently designated
for this chassis. This baffle ensures proper
cooling of installed memory DIMMs.
Memory
Air Baffle
DO NOT
REMOVE!
Underside of
processor air
duct shown.
18
Re-install Hot Swap
Fans (SC5400LX only)
Slide each fan into the chassis until the latch locks
into place.
A
A
Fan
Latch
23
Re-install Bezel Assembly
Set chassis upright if not
already in upright position.
A
Close the outer bezel door.
C
Open the front door of the bezel assembly and
remove bezel filler panel[s] that correspond to installed devices.
B
Fit right edge of bezel assembly against front of chassis and
engage plastic bezel hooks into raised metal slots at chassis edge.
D
Rotate bezel assembly toward chassis and latch two plastic tabs on
left side of bezel assembly to chassis.
E
E
A
B
C
B
E
E
E
D
D
E
CAUTION: Do not attach bezel assembly
to chassis at MORE than a 40 degree angle.
40
°
Max
15
Install Fixed Cage into
Chassis
A
Push HDD cage into
bay until blue plastic
retention mechanism
locks into place.
A
Connect data and power cables
to each drive.
B
B
Chassis Features and Components
1. Hot Swap Power Supply
2. Second Hot Swap Power
Supply (accessory)
3. Rear Serial-B Connector
4. PCI Add-in Card Panel
5. Memory Air Duct
6. Processor Air Duct
7. Hot Swap Fans - Large (2)
8. Hot Swap Fans - Small (2)
9. Hard Disk Drive Cage
Release Mechanisms (2)
10. Front Panel Controls
11. 5.25-inch Device Bays (3)
12. Front Panel USB/Serial B
13. Hot Swap Drive Cage - 4 Drive
(accessory)
14. Hot Swap Drive Cage - 6 Drive
(accessory)
1. Fixed Power Supply
2. Rear Serial B Connector
3. PCI Add-in Card Panel
4. Memory Air Duct
5. Processor Air Duct
6. Fixed Fans (2)
7. Hard Disk Drive Cage
Release Mechanisms (2)
8. Front Panel Controls
9. 5.25-inch Device Bays (3)
10. Front Panel USB/Serial B
11. Fixed Drive Cage - 4 Drive
(accessory)
12. Fixed Drive Cage - 6 Drive
1
3
2
Intel
®
Server Chassis
SC5400Base Components
Intel
®
Server Chassis
SC5400LX with Hot
Swap Components
1
4
3
2
Notes: • Intel
®
Server Chassis SC5400BRP not shown.
• Rack mount configurations are shown in the rack mount
conversion kit documentation.
7
8
9
10
11
12
13
14
6
5
6
12
7
8
11
5
4
10
9
A complete list of accessories and spares can be found at:
www.intel.com/go/serverbuilder
21
Install Additional Hot Swap
Power Supply Module (optional)
Note: If your chassis has a fixed power supply, go to Step 22.
Remove two screws and
remove power supply
filler panel.
Secure with screw as shown
only if shipping chassis to
another location.
Insert power supply module
until it clicks into place.
A
B
C
A
B
A
17
Install Add-in Cards
PCI Slot
C
D
E
Close back panel PCI add-in
card retention device.
D
Replace PCI add-in card retainer.
E
PCI Slot
Shield
B
Insert add-in card into
server board PCI slot.
Open back panel PCI add-in card
retention device by pressing open
from inside of chassis.
A
C
Remove PCI slot shield by
pushing out from inside of
chassis.
B
PCI Add-in Card
Retention Device
(located on rear of chassis)
A
20
Re-install Air Ducts
Note: This step only applies if your system has
two processors. If only one processor is
installed, leave the air baffle in place.
Remove the air baffle from inside of
the processor air duct.
A
A
Processor 2
Air Baffle
(Remove only
if system has
two processors.)
Underside
of processor
duct shown.
Processor
Air Duct
Memory
Air Duct
Congure Processor Air Duct for
Two Processors:
Read this Before Installing Air Ducts! Install Processor and
Memory Air Ducts
These two tabs slide into matching
hooks on the chassis center wall.
A
These two tabs slide into matching slots on
the top edge of the chassis center wall.
B
This edge of the memory duct sits on
top of the processor duct.
D
This large tab on the memory air duct
interlocks with the matching slot
on the processor duct.
C
Two small tabs on the
memory duct insert into
matching slots on the
processor duct.
E
Memory duct latching tab.
F
Push this tab to release the
memory duct from the chassis wall.
G
Note: Before installing the two air ducts, it is important
to view the features that interconnect or latch.
B
A
A
C
G
Push to
release
D
E
F
Hooks
Slots
Memory
Duct
Latch
Install
the processor air
duct first. Make sure that
tabs engage their
matching chassis hooks
before inserting tabs
into chassis slots.
1
Install
the memory air
duct last. Holding the
large-tab end at a
downward angle, insert
the large tab from
the underside of the
processor duct. Then
rotate the memory duct
downward until the two
small tabs engage
and the memory duct
snaps into place at .
Note: Use care to avoid pinching
wires and cables.
2
1
2
Top View of Intel
®
Server
Chassis SC5400
C
F
A
B
E
25
Finishing Up
2. Connect the AC
power cable last.
1. See your Intel
®
Server Board
Quick Start User's
Guide to connect
your keyboard,
mouse, video, and
other I/O cables.
AC
Power
Serial B
I/O Connections
Intel® Server Chassis SC5400
with Fixed Power Supply
I/O Connections
Intel® Server Chassis SC5400
with Hot Swap Power Supply
Serial B
AC
Power
CAUTION:
830 watt and 670
watt power supplies
require a 16-gauge
power cord.
ARIGRACK
4-Drive SAS/SATA Bay
Rack Conversion Accessory Kit
AXX6DRV3G
6-Drive SAS/SATA Bay
Accessories and Order Codes
AXX4DRV3GEXP4-Drive SAS/SATA Bay (Expander)
AXX4DRV3G
6-Drive SAS/SATA Bay (Expander)
AXX4FIXDB
AXX6DRV3GEXP
4-Drive Fixed Drive Bay
AXXLCPPED
Intel® Local Control Panel
AXXCMA3U7U
Cable Management Arm
830W Power Supply Module
FPWRCABLENA
North American Power Cable
AXXCDUSBFDBRK
Slimline USB CD-Floppy Drive
FXX830WPSU
ARIG2PMKIT
Preventative Maintenance Kit
CAUTION: For a one-processor
configuration, the air baffle must
be installed to ensure proper
cooling.
16
Install Server
Board
Open the Intel
®
Server Board box. Follow the
instructions in the enclosed Intel
®
Server
Board Quick Start User's Guide and return
to this document when finished.
Note: Follow the instructions in the RAID
card Quick Start Guide for RAID card installation
and cable routing.
Processor 2
Air Baffle