Quick Start Guide Back

Side 2
22
Replace Side Cover
Re-install side cover and latch securely.
Side Cover
CAUTION: This chassis must be
operated with the SIDE COVERS
installed to ensure proper cooling.
13
Install Hard Drives into Fixed Drive Bay
A. Open Cage Access Doors B. Remove Device Slides
C. Install Slides to Hard Drive
Note: Device slides are
"tool-less". Insert slide
tabs into hard drive
mounting holes and
press firmly into place.
D. Insert Drive/Slide Assembly
into Cage
Note: Make sure connector end of drive
faces toward the rear of the cage.
Rear
of Cage
Loosen the
captive thumb
screw, then
open the
upper door.
Open the
lower door.
Connector
end of drive
to back.
Ta b
Close cage doors and tighten captive
thrumb screw. Repeat this procedure
for each drive.
Front Panel Controls
and Indicators
A. ID Button
B. System Reset
Button
C. NIC1 LED
D. System Power
Button
E. Hard Drive
Activity LED
F. System ON
LED
G. NIC2 LED
H. ID LED
I. Status LED
J. NMI Button
A
B
C
D
E
F
G
H
I
J
Reference
20
Rack Mount
Conguration
(optional)
If you intend to configure
your server as a pedestal
system, disregard this
step.
If you intend to configure
your server as a rack-
mount system, go to the
instructions that came
with your rack-mount kit
to complete your server
assembly.
17
Re-install Hot-Swap
Fans (SC5600LX only)
Slide each fan into the chassis until the latch locks
into place.
A
A
Fan
Latch
21
Re-install Bezel Assembly
Set chassis upright if not
already in upright position.
A
Close the outer bezel door.
C
Open the front door of the bezel assembly and
remove bezel filler panel[s] that correspond to installed devices.
B
Fit right edge of bezel assembly against front of chassis and
engage plastic bezel hooks into raised metal slots at chassis edge.
D
Rotate bezel assembly toward chassis and latch two plastic tabs on
left side of bezel assembly to chassis.
E
E
A
B
C
B
E
E
E
D
D
E
CAUTION: Do not attach bezel assembly
to chassis at MORE than a 40 degree angle.
40
°
Max
14
Install Fixed Cage into
Chassis
A
Push HDD cage into
bay until blue plastic
retention mechanism
locks into place.
A
Connect data and power cables
to each drive.
B
B
16
Install Add-in Cards
PCI Slot
C
D
E
Close back panel PCI add-in
card retention device.
D
Replace PCI add-in card retainer.
E
PCI Slot
Shield
B
Insert add-in card into
server board PCI slot.
Open back panel PCI add-in card
retention device by pressing open
from inside of chassis.
A
C
Remove PCI slot shield by
pushing out from inside of
chassis.
B
PCI Add-in Card
Retention Device
(located on rear of chassis)
A
Chassis Features and Components
Notes: Intel
®
Server Chassis SC5600BRP not shown.
Rack-mount configurations are shown in the rack-mount
conversion kit documentation.
Intel® Server Chassis
SC5600LX with Hot-
Swap Components
1. Hot-Swap Power Supply #2
2. Hot-Swap Power Supply #1
3. Rear Serial-B Connector
4. PCI Add-in Card Panel
5. Memory/Processor Air Duct
6. Hot Swap Fans - Large (2)
7. Hot Swap Fans - Small (2)
8. HDD Cage Release
Mechanisms (2)
9. Front Panel Control
10. 5.25" Device Bays (3)
11. Front Panel USB/Serial B
12. Hot-Swap Drive Cage - 4 Drive
(accessory)
13. Hot-Swap Drive Cage - 6 Drive
(accessory)
1
2
3
4
5
6
7
8
9
10
11
12
13
1. Fixed Power Supply
2. Rear Serial-B Connector
3. PCI Add-in Card Panel
4. Memory/Processor Air Duct
5. Fixed Fans (2)
6. HDD Cage Release
Mechanisms (2)
7. Front Panel Control
8. 5.25" Device Bays (3)
9. Front Panel USB/Serial B
10. Fixed Drive Cage - 4 Drive
(accessory)
11. Fixed Drive Cage - 6 Drive
1
2
3
4
5
6
7
8
9
10
11
Intel® Server Chassis
SC5600Base Components
19
Install Additional Hot-Swap
Power Supply Module
(optional)
Note: If your chassis has a fixed power supply, go to Step 20.
Release the latch and
remove the power
supply filler panel.
Insert power supply
module until it clicks
into place.
A
B
Latch
15
Install Server
Board
Open the Intel
®
Server Board box. Follow the
instructions in the enclosed Intel
®
Server
Board Quick Start User's Guide and return
to this document when finished.
Note: Follow the instructions in the RAID
card Quick Start Guide for RAID card installation
and cable routing.
Accessories and Order Codes
4-Drive SAS/SATA Bay
6-Drive SAS/SATA Bay
6-Drive SAS/SATA Bay (Expander)
4-Drive Fixed Drive Bay
Intel
®
Local Control Panel
AXX4DRV3GR
AXX6DRV3GR
AXX6DRV3GEXP
AXX4FIXDB
AXXLCPPED
Cable Management Arm
AXXCMA3U7U
750W Power Supply Module
AXX750WPS
Rack Conversion Accessory Kit
ARIGRACK
4-Drive SAS/SATA Bay (Expander)
AXX4DRV3GEXP
North American Power Cable
FPWRCABLENA
Tower Passive Heat Sink for the
Intel
®
Server Chassis SC5600LX*
FXXRGTHSINK
23
Finishing Up
2. Connect the AC
power cable last.
1. See your Intel
®
Server Board
Quick Start User's
Guide to connect
your keyboard,
mouse, video, and
other I/O cables.
AC
Power
Serial B
I/O Connections
Intel
®
Server Chassis SC5600
with Fixed Power Supply
I/O Connections
Intel
®
Server Chassis SC5600
with Hot-Swap Power Supply
Serial B
AC
Power
CAUTION:
750 watt and 670
watt power supplies
require a 16-gauge
power cord.
Connections for Intel® Server Board S5520HC,
S5500HCV and Intel® Workstation Board S5520SC
Note: For a non-Intel Chassis, see your chassis documentation for server board connection information.
Optional Connections
HSBP_A
HSBP_B
USB_Front Panel
SATA Connectors
SATA Software RAID 5 Key
SAS Module SAS Connectors (optional)
Serial B
SATA SGPIO
SAS Module SES (optional)
SAS Module SGPIO (optional)
SAS Software RAID 5 Key (optional)
Intel
®
Server Chassis SC5600Base/BRP
CPU/System Fan Connections
CPU Fan 1 Header
CPU Fan 2 Header
Chassis Fan 1 Header
Chassis Fan 2 Header
Chassis Fan 3 Header
Chassis Fan 4 Header
Chassis Fan 5 Header
(Small front chassis fan)
(Large front chassis fan)
(rear chassis fan)
Intel
®
Server Chassis SC5600Base/BRP
Required Connections
CPU 1 Power Connector
CPU 2 Power Connector
Main Power Connector
Auxiliary Power Connector
Front Panel Header
Intel
®
Server Chassis SC5600Base/BRP
Intel
®
Server Chassis SC5600LX
Intel
®
Server Chassis SC5600LX
Intel
®
Server Chassis SC5600LX
(Either SAS SES or SGPIO)
(Either SAS SES or SGPIO)
(Either SAS SES or SGPIO)
(Either SAS SES or SGPIO)
Preventative Maintenance Kit
ARIGTPMKIT
*This accessory is required when using the Intel
®
Server
Chassis SC5600LX
Document Type
Reference Documentation
Technical Product Specification
Spares and Configuration Guide
Software and Drivers
Content
In-depth technical information
Supported accessories and spares list
Up-to-date firmware, driver and utility information
These and additional reference documents can be found at: http://support.intel.com
18
Re-install Air Duct
Read this Before Installing the
SC5600BASE and SC5600BRP
Air Duct!
Chassis alignment holes for air duct.
A
Air duct alignment holes.
B
Align the air duct and chassis rails.
D
Install the air duct. Ensure that alignment
holes match up, then engage the latch.
E
Note: Before installing the air duct,
it is important to view the features
that interconnect or latch.
To install the air duct:
A
Read this Before Installing the
SC5600LX Air Duct!
Chassis alignment holes for air duct.
A
Air duct alignment holes.
B
Air duct alignment tabs.
C
Align the air duct and chassis rail.
G
Install the air duct. Ensure that
alignment holes and tabs match up,
then engage the latch.
H
Chassis alignment slots for air duct.
D
Note: Before installing the air duct, it is important
to view the features that interconnect or latch.
To install the air duct:
A
C
Air duct and chassis alignment rails.
E
Air duct and chassis alignment rails.
F
Air duct alignment tab and matching
chassis alignment slot.
WARNING: Improper installation and
removal of the air duct can cause
damage to the server board. Install and
remove the air duct with caution.
B
SC5600BASE/BRP Air Duct
E
Inlet Filler Board Removal Detail
Warning! Remove the inlet filler board
for dual processor configuration
(SC5600Base/BRP Air Duct only)
Chassis
Alignment Rails
Air Duct
Alignment Rails
Chassis Rear Fan Bracket
C
C
D
D
D
H
SC5600LX
Air Duct
C
B
G
Chassis
Alignment Rails
Chassis Rear Fan Bracket
E
Air Duct
Alignment Rails
E
H
WARNING: Improper installation and
removal of the air duct can cause
damage to the server board. Install and
remove the air duct with caution.
F

Summary of content (1 pages)