Intel® Server Chassis SC5600 Service Guide A Guide for Technically Qualified Assemblers of Intel® identified Subassemblies/Products Order Number: E39533-003 Revision 1.
Disclaimer Disclaimer ® Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Safety Information Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also ® Intel Server Boards and Server Chassis Safety Information on the Intel Server Deployment Toolkit 3.0 CD and/or at: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen.
Warnings Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
Preface Preface About this Manual ® Thank you for purchasing and using the Intel Server Chassis SC5600. This manual is written for system technicians responsible for troubleshooting, upgrading, and repairing this server chassis. This document provides a brief overview of the features of the board/chassis, list of accessories or other components you may need, troubleshooting information, and instructions on how to add ® and replace components on the Intel Server Chassis SC5600.
Preface / NOTE ® ® When installing either the Intel Server Board S5520HC or S5500HCV in the Intel Server Chassis SC5600LX, a passive processor heat sink (FXXRGTHSINK) is required.
Preface For information about compatible accessories, memory, processors, and third-party hardware and ordering information for Intel products, see: http://support.intel.com/support/motherboards/server/chassis/SC5600/compat.htm Additional Information and Software If you need more information about this product or information about the accessories you can use with this server chassis, use the following resources. You can find these files at: http://support.intel.
Preface
Contents Contents Safety Information ............................................................................................. iii Preface ................................................................................................................ v 1 Server Chassis Features .............................................................................. 1 Component Identification ..........................................................................................................
Contents Replacing a Fixed Power Supply............................................................................................ 49 Replacing the Hot Swap Power Supply Power Distribution Board ........................................ 50 Replacing the Control Panel ................................................................................................... 54 Installing and/or Removing a Server/Workstation Board .......................................................
Contents Warnungen zu Netzspannung und Elektrizität .............................................................. 72 Warnhinweise für den Systemzugang ........................................................................... 73 Warnhinweise für Racks ................................................................................................ 73 Elektrostatische Entladungen (ESD) ............................................................................. 73 Andere Gefahren .........................
Figures Figures Figure 1. Intel® Server Chassis SC5600 ........................................................................................ 1 Figure 2. Intel® Server Chassis SC5600Base Components Location ........................................... 5 Figure 3. Intel® Server Chassis SC5600LX Components Location ............................................... 6 Figure 4. Front Control Panel .........................................................................................................
Figures and Tables Figure 50. Preparing Chassis for Addition of PCI add-in board ................................................... 45 Figure 51. Installing PCI Add-in Board ......................................................................................... 46 Figure 52. Reinstalling PCI Add-in Card Retainer ....................................................................... 47 Figure 53. Removing Hot Swap Power Supply from Chassis......................................................
Server Chassis Features 1 Server Chassis Features ® This chapter briefly describes the main features of the Intel Server Chassis SC5600. This chapter provides a list of the server chassis features and diagrams showing the location of important components and connections on the server chassis. Figure 1. Intel® Server Chassis SC5600 ® Table 1 summarizes the features of the Intel Server Chassis SC5600Base SKU. Table 1.
Server Chassis Features Feature Description ® selected) Intel Local Control Panel (Optional) LEDs and displays (dependent on option selected) With Front Control Panel • NIC1 Activity • NIC2 Activity • Power/Sleep • System Status • System Identification • Hard Drive Activity Power Supply One fixed 670-W PFC (Power Factor Correction) Power Supply with an integrated cooling fan Fans Three fixed, non-redundant system fans: • One 120-mm front fan • One 92-mm front fan • One 120-m
Server Chassis Features Feature Description • System Status • System Identification • Hard Drive Activity Power Supply (1+1) hot-swap redundant PFC high-efficiency 750-W PMBus-compliant power supply with integrated cooling fans.
Server Chassis Features Power Supply with integrated cooling fans, Second redundant 750-W module included Fans Four hot-swap, redundant chassis fans: • Two 120-mm front fans • Two 92-mm front pans One air duct 4 Processor Heat Sink Processor heat sink is not included Passive tower processor heat sink(s) (FXXRGTHSINK) is required when used ® with compatible Intel server/workstation board Supports up to 95-W processor USB 2.
Server Chassis Features Component Identification 1. Fixed Power Supply 7. Front Control Panel 2. Rear Serial B Connector 8. 5.25-inch Device Bays (optional optical drive shown) 3. PCI Add-in Card Panel 9. Front Panel USB/Serial B 4. Air Duct and Rear Fixed Fan 10. Fixed Drive Cage 4-Drive (accessory) 5. Front Fixed Fans (2) 11. Fixed Drive Cage 6-Drive 6. Hard Disk Drive Cage Release Mechanisms (2) Figure 2.
Server Chassis Features 1. Hot-swap Power Supply #2 8. Hard Disk Drive Cage Release Mechanism (2) 2. Hot-swap Power Supply #1 9. Front Control Panel 3. Rear Serial B Connector 10. 5.25-inch Device Bays (optional optical drive shown) 4. PCI Add-in Card Panel 11. Front Panel USB/Serial B 5. Air Duct 12. Hot-swap Drive Cage 4-Drive (accessory) 6. Hot-swap Fans – Large (2) 13. Hot-swap Drive Cage 6-Drive (accessory) 7. Hot-swap Fans –Small (2) Figure 3.
Server Chassis Features Front Control Panel A. ID LED Toggle Switch F. NIC2 Activity LED (green) B. Reset Button G. ID LED (blue) C. NIC1 Activity LED (green) H. Status LED (bi-color) D. Power Button I. NMI Button E. Hard Drive Activity LED (green) Figure 4.
Server Chassis Features Descriptions of the front control panel LEDs are listed in the following table. See your server/workstation documentation for functionality of the buttons. Table 4.
Server Chassis Features Callout A B C D E Function LCD display (variable content) LCD up navigation button LCD down navigation button LCD backup level navigation button LCD command enter button Figure 5.
Server Chassis Features Callout A B C D E F / Function Fixed Power Supply I/O Ports PCI Add-in Card Slots PCI Card Latch Rear Serial B Connector (optional) AC Power Connector NOTE I/O ports vary, depending on the server/workstation board installed. See your server board documentation for port identification. Figure 6.
Server Chassis Features Peripheral Devices The chassis provides locations and hardware for installing hard drives, CD-ROM drive, DVD-ROM drive, or a tape drive. You must purchase the drives separately. The following figure shows the available options. Callout A. B. C. D. Function DVD-ROM drive/CD-ROM drive (Optional) Front USB ports (2) 4-Bay hot-swap hard disk drive bay (optional) 6-Bay hot-swap hard disk drive bay (optional) Figure 7.
Server Chassis Features Standard and Optional Hot-swap Drive Bays One bay supporting six cabled drives ships with the standard chassis. Optional hot-swap drive bays may replace the 6-drive fixed drive bay. An optional 4-drive fixed drive bay (for cabled drives) is available. No tools are required to replace the fixed drive bays. Optional 4-drive and 6-drive SAS/SATA are available. For instructions on installing hard drives, see “Removing and Installing Hot Swap Drive(s)” on page 55.
Server Chassis Features Tower Passive Processor Heat Sink (FXXRGTHSINK) ® This tower passive heat sink (FXXRGTHSINK) is required when installing the Intel Server Board ® S5520HC/S5500HCV into the Intel Server Chassis SC5600LX. Two tower heat sinks are required for dualprocessor installation. ® ® This tower passive heat sink is NOT required for other Intel Server Chassis in the Intel Server Chassis SC5600 families.
Hardware Installations and Upgrades 2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to “Appendix B: Safety Information.” This document provides instructions for adding and replacing chassis components. For instructions on replacing components on the server board, such as the processor and memory DIMMs, see the instructions provided with the server/workstation board.
Hardware Installations and Upgrades Removing and Installing the Chassis Cover Removing the Chassis Cover ® You must operate the Intel Server Chassis SC5600 with the top cover in place to ensure proper cooling. You must remove the top cover to add or replace components inside of the platform. Before removing the top cover, power down the server and unplug all peripheral devices and the AC power cable.
Hardware Installations and Upgrades Installing the Chassis Cover 1. Slide the chassis cover on the chassis. 2. Latch the cover securely to the chassis. 3. If the chassis will be re-shipped, secure the chassis cover to the chassis with the access cover screw (see letter “A” in the following figure). Figure 9.
Hardware Installations and Upgrades 3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.” 4. Release the two plastic tabs (see letter “A” in the following figure) on the left side of the bezel assembly to disengage the tabs. 5. Rotate the bezel assembly (see letter “B”) no more than 40° outward. 6. At a 40° angle, push the bezel assembly away from the chassis (see letter “C”). 7.
Hardware Installations and Upgrades 4. Fit the right edge of the bezel assembly against the right side of the chassis. 5. Engage the plastic bezel hooks (see letter “D”) into the raised metal slots at the chassis edge. 6. Rotate the bezel assembly toward the chassis. 7. Latch the two plastic tabs (see letter “E”) on the left side of the bezel assembly to the chassis. Figure 11.
Hardware Installations and Upgrades 4. Unlatch the air duct from the chassis by pressing the tab at the rear of the air duct located on the rear system fan bracket (See letter “A”). 5. Grasp the air duct and remove (see letter “B”). Figure 12. Removing the Air Duct Installing the Air Duct Installing the Air Duct in Intel® Server Chassis SC5600Base and SC5600BRP 1.
Hardware Installations and Upgrades Figure 13. Installing the Air Duct into Intel® Server Chassis SC5600Base and SC5600BRP / NOTE Use care to avoid pinching the cables. Installing the Air Duct in the Intel® Server Chassis SC5600LX 1. 20 Install the air duct.
Hardware Installations and Upgrades Figure 14. Installing the Air Duct into Intel® Server Chassis SC5600LX / NOTE Use care to avoid pinching the cables. Replacing a Fixed Fan (Intel® Server Chassis SC5600Base and SC5400BRP only) / NOTE ® ® This procedure applies only to the Intel Server Chassis SC5600Base and Intel Server Chassis SC5600BRP configurations. Intel® 1. Observe the safety and ESD precautions at the beginning of this book. 2.
Hardware Installations and Upgrades C A B = Figure 15. Removing a Fixed Fan 7. Install a new 92-mm or 120-mm fixed fan. 8. Connect the fan power cable to the server/workstation board. See the Quick Start User’s Guide or Service ® Guide provided with your Intel server/workstation board for the appropriate connection location. 9. Install the air duct if it was removed in a previous step. For instructions, see “Installing the Air Duct.” 10.
Hardware Installations and Upgrades 2. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.” 3. Press the latch on the fan (see letter “A” in Figure 16) and pull on the handle to remove the hot swap fan from the chassis. 4. For removal of the remaining hot swap fans, repeat Step 3. Figure 16. Removing Hot Swap Fan Installing Hot Swap Fans / NOTE ® ® This procedure applies only to the Intel Server Chassis SC5600LX configurations.
Hardware Installations and Upgrades Figure 17. Installing Hot Swap Fan Removing and Installing a DVD- or CD-ROM Drive Removing a DVD- or CD-ROM Drive 24 1. Observe the safety and ESD precautions at the beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.” 4. If it is installed, remove the front bezel. For instructions, see “Removing and Installing the Front Bezel.
Hardware Installations and Upgrades Figure 18. Removing DVD or CD-ROM Drive 7. If you are not replacing with another drive, re-attach a pair of slides to an EMI shield and reinsert the EMI shield/slide assembly into the chassis for proper airflow. Figure 19. Re-inserting Empty EMI Shield/Slide Assembly 8. Install the front bezel. For instructions, see “Removing and Installing the Front Bezel.” 9. Install the chassis cover. For instructions, see “Installing the Chassis Cover.” 10.
Hardware Installations and Upgrades Figure 20. Removing EMI Shield/Slide Assembly from Upper Device Bay 6. Attach slides to the DVD or CD-ROM drive by pressing the slides firmly into the side dimples on the DVDor CD-ROM drive. Figure 21. Attaching Slides to a DVD or CD-ROM Drive 7. Insert the drive/slide assembly into the upper device bay until the slides lock into place. 8. Connect power and data cables. 9. Install the front bezel. For instructions, see “Removing and Installing the Front Bezel.
Hardware Installations and Upgrades Removing and Installing Fixed Hard Drive(s) Removing Fixed Hard Drive(s) / 1. Observe the safety and ESD precautions at the beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.” 4. If it is installed, remove the front bezel. For instructions, see “Removing and Installing the Front Bezel.” 5.
Hardware Installations and Upgrades 8. Loosen the thumb screw (see letter “A” in Figure 23). Open the upper door of the drive cage (see letter “B”). Figure 23. Unlocking and Opening Upper Door of Fixed Drive Cage 9. Open the lower door. Figure 24. Opening Lower Door of Fixed Drive Cage 10. Remove the drive/slide assembly from the drive cage.
Hardware Installations and Upgrades Figure 25. Removing Drive/Slide Assembly from Fixed Drive Cage 11. Remove the device slides from the hard drive. If not replacing the hard drive, insert the empty device slides into the drive cage. Figure 26. Inserting Empty Device Slides into Fixed Drive Cage 12. Close the lower door of the drive cage.
Hardware Installations and Upgrades Figure 27. Closing Lower Door of Fixed Drive Cage 13. Close the upper door. Figure 28. Closing Upper Door of Fixed Drive Cage 14. Tighten the captive screw.
Hardware Installations and Upgrades Figure 29. Tightening Thumb Screw 15. Reinstall the fixed hard drive into the chassis. 16. If other hard drives remain in the drive cage, reconnect the power and data cables. 17. Install the front bezel. For instructions, see “Removing and Installing the Front Bezel.” 18. Install the chassis cover. For instructions, see “Installing the Chassis Cover.” 19. Plug all peripheral devices and the AC power cable into the server. 20. Power up the server.
Hardware Installations and Upgrades Figure 30. Removing Six-drive Fixed Drive Cage from Chassis 6. Loosen the captive screw (see letter “A” in Figure 31). Open the upper door (see letter “B”). Figure 31. Unlocking and Opening the Upper Door of Fixed Drive Cage 7. 32 Open the lower door.
Hardware Installations and Upgrades Figure 32. Opening Lower Door of Fixed Drive Cage 8. Remove a pair of device slides from the drive cage. Figure 33. Removing Slides from Fixed Drive Cage 9. Intel® Server Attach the device slides to the hard drive. This is a tool-less operation. Insert pins on device slides into mounting holes on the hard drive. Press firmly to secure device slides to the hard drive.
Hardware Installations and Upgrades Figure 34. Attaching Device Slides to Hard Drive 10. Insert the drive/slide assembly into the drive cage. Make sure the cable connector end of the hard drive faces towards the rear of the drive cage. Figure 35. Inserting Drive/Slide Assembly into Drive Cage 11. For installation of additional hard drives into the drive cage, repeat the previous steps. 12. Close the lower door of the drive cage.
Hardware Installations and Upgrades Figure 36. Closing Lower Door of Fixed Drive Cage 13. Close the upper door. Figure 37. Closing Upper Door of Fixed Drive Cage 14. Tighten the captive screw.
Hardware Installations and Upgrades Figure 38. Tightening Thumb Screw 15. Re-install the fixed drive cage into the chassis. 16. Connect the power and data cables to the connectors on the hard drive(s). 17. Install the front bezel. For instructions, see “Removing and Installing the Front Bezel.” 18. Install the chassis cover. For instructions, see “Installing the Chassis Cover” on page 27. 19. Plug all peripheral devices and the AC power cable into the server. 20. Power up the server.
Hardware Installations and Upgrades Routing Power Cables to Fixed Drives Route the longest power cables to the 6-drive bay and shorter cables to the 4-drive bay and upper device bay. Figure 39.
Hardware Installations and Upgrades Routing Data Cables to Fixed Drives / NOTE Front panel, USB cables are pre-routed by the factory. SAS or SATA cables are supplied with the server board and hot-swap drive accessory kits. No cables are supplied with the fixed drive bay kit. Route SAS/SATA data cables through the chassis openings located near the bottom of the drive cage. Connect data cables to the respective fixed drive and to the appropriate connector on the server board. Figure 40.
Hardware Installations and Upgrades Removing and Installing Hot Swap Drive(s) Removing Hot Swap Drive(s) 1. Press in on the green latch (see letter “A” in Figure 41) at the end of the drive carrier to disengage it from the hot swap drive cage. Pull out on the black lever (see letter “B”) to fully open the drive carrier. When the lever reaches a fully opened position, it will push the drive carrier out from the hot swap drive cage. Slide the drive carrier out of the drive cage (see letter “C”). Figure 41.
Hardware Installations and Upgrades 3. / If not replacing with another hard drive, re-install the plastic air baffle into the empty drive carrier. Secure the plastic air baffle to the drive carrier using the four screws previously attached to the hard drive. NOTE Plastic air baffles are necessary in all empty drive carriers to ensure proper airflow within the chassis. Figure 43. Securing Plastic Air Baffle in Drive Carrier 4. With the black lever open, insert the drive carrier into the drive cage.
Hardware Installations and Upgrades Installing Hot Swap Drive(s) 1. Press in on the green latch (see letter “A” in Figure 45) at the end of the drive carrier to disengage it from the hot swap drive cage. Pull out on the black lever (see letter “B”) to fully open the drive carrier. When the lever reaches a fully opened position, it will push the drive carrier out from the hot swap drive cage. Slide the drive carrier out of the drive cage (see letter “C”). Figure 45.
Hardware Installations and Upgrades Figure 47. Securing Hard Drive to Drive Carrier 4. With the black lever open, insert the drive carrier into the drive cage. Once inserted, rotate the black lever upwards to latch the drive carrier into position. Figure 48.
Hardware Installations and Upgrades Removing and Installing PCI Add-in Board(s) Removing PCI Add-in Board(s) CAUTIONS When removing a full-length add-in card, you must pull back the latch on the plastic card guide at the front of the chassis to release the card from the card guide. 1. Observe the safety and ESD precautions at the beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover.
Hardware Installations and Upgrades 7. Firmly grab the PCI add-in board by its top edge or outer corners and remove from the expansion slot on the server board. Place the removed PCI add-in board in an anti-static protective wrapper. Close the back panel PCI add-in card retention device. 8. Remove additional PCI add-in boards as necessary. When done, reinstall the PCI add-in card retainer and close the PCI add-in card retention device(s). 9. Install the front bezel.
Hardware Installations and Upgrades Figure 50. Preparing Chassis for Addition of PCI add-in board Intel® 6. Remove the PCI add-in board from its protective wrapper. Be careful not to touch the components or gold edge connectors. Place the add-in board on an anti-static surface. Record the type and serial number of the add-in board in your equipment log. Set the jumpers or switches on the board according to the manufacturer’s instructions. 7. Hold the PCI add-in board by its top edge or upper corners.
Hardware Installations and Upgrades Figure 51. Installing PCI Add-in Board 46 8. Repeat steps 2 through 10 until all PCI add-in cards are installed. 9. Reinstall the PCI Add-in Card Retainer.
Hardware Installations and Upgrades Figure 52. Reinstalling PCI Add-in Card Retainer 10. Attach cables if necessary. 11. Install the front bezel. For instructions, see “Removing and Installing the Front Bezel.” 12. Install the chassis cover. For instructions, see “Installing the Chassis Cover.” 13. Plug all peripheral devices and the AC power cable into the server. 14. Power up the server.
Hardware Installations and Upgrades Replacing a Hot Swap Power Supply WARNING Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel only. 1. Remove the power cable from the defective hot swap power supply. 2.
Hardware Installations and Upgrades Replacing a Fixed Power Supply WARNING Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel only. 1. Observe the safety and ESD precautions at the beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.
Hardware Installations and Upgrades Replacing the Hot Swap Power Supply Power Distribution Board WARNING Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel. 1. Observe the safety and ESD precautions at the beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover.
Hardware Installations and Upgrades Figure 57. Removing Power Supply Filler Panel from Chassis 8. Remove the screws (see letters “A”, “B”, “C”, “D”, and “E” in Figure 58) securing the power supply cage to the chassis. Figure 58. Removing Screws Securing Hot Swap Power Supply Cage 9. Remove the power supply cage from the chassis. You may have to feed the power cables through the chassis power supply bay while removing the hot swap power supply cage. Figure 59.
Hardware Installations and Upgrades / NOTE Cables on the back of the power distribution board are not shown to clarify the removal process. Figure 60. Removing Power Distribution Board from Hot Swap Power Supply Cage 11. Attach the new power distribution board to the hot swap power supply cage, position the power distribution board screw holes to the matching power supply cage mounting holes (see letter “A” and “B” in Figure 61), and secure the screws.
Hardware Installations and Upgrades Figure 62. Inserting Hot Swap Power Supply Cage in Chassis 13. Tighten screws to secure the power supply cage to the chassis (see letters “A”, “B”, “C”, “D” and “E” in Figure 63). Figure 63. Securing Hot Swap Power Supply Cage to Chassis 14. Reinstall the filler panel board, and install the screws to secure the filler panel board to the chassis (see letters “A” and “B” in Figure 64). Figure 64. Installing Filler Panel board on the Chassis 15.
Hardware Installations and Upgrades Figure 65. Inserting Hot Swap Power Supplies into Chassis 16. Re-install the air duct. For instructions, see “Installing the Air Duct.” 17. Re-install the chassis cover. For instructions, see “Installing the Chassis Cover.” 18. Plug all peripheral devices and the AC power cable into the server. 19. Power up the server. Replacing the Control Panel ® The steps for replacing the front control panel and the Intel Local Control Panel are nearly identical.
Hardware Installations and Upgrades 7. Disconnect the cables. 8. Install the control panel module into the chassis. 9. Reconnect the cables. 10. (Optional) Install the front bezel. For instructions, see “Removing and Installing the Front Bezel.” 11. Install the chassis cover. For instructions, see “Installing the Chassis Cover.” 12. Plug all peripheral devices and the AC power cable into the server. 13. Power up the server.
Hardware Installations and Upgrades Connecting and Disconnecting Cables to or from Server Workstation Board CAUTION Use caution when routing cables to ensure that cables do not obstruct fan airflow. ® See your Intel Server/Workstation Board Service Guide or Quick Start User’s Guide for cable connection locations. If your server has a hot swap power supply, secure the cables (that route toward the server/workstation board) to the chassis. Connecting Cables to Server/Workstation Board 1.
Technical Reference 3 Technical Reference Power Supply Specification 670-W Single Power Supply Input Voltage 100-127 V at 50/60 Hz; 12 A max. 200-240 V at 50/60 Hz; 7 A max. 670-W Single Power Supply Output Voltages The following table lists the total wattage available from the power subsystem for each voltage. Ensure your loads do not exceed the combined total wattage of 670 W. For information about calculating the power usage for your configuration, see “Calculating Power Usage.” Table 5.
Technical Reference Table 6. 750-W Hot Swap Power Supply Output Capability Voltage Maximum Current + 3.3 V 24 A +5 V 30 A +12 V1 24 A +12 V2 24 A +12 V3 16 A +12 V4 16 A -12 V 0.5 A +5 VSB 3.0 A WARNING Do not exceed a combined power output of 170 W for the +5 V and +3.3 V outputs. Exceeding a combined 170 W will overload the power subsystem and may cause the power supplies to overheat and malfunction.
Technical Reference Current Usage Calculation Power Usage The total combined wattage for your configuration must be less than the wattage rating for your power supply. Use the two worksheets in this section to calculate the total used by your configuration. For current and voltage requirements of add-in boards and peripherals, see your vendor documents. Worksheet, Calculating DC Power Usage Table 8. Power Usage Worksheet Device Current (maximum) at voltage level +3.
Technical Reference Device Current (maximum) at voltage level +3.3 V +5 V -5 V +12 V -12 V 5 V Standby Control Panel Total Current Worksheet, Total Combined Power Used by the Server From the previous worksheet, enter the total current for each column. Multiply the voltage by the total current to get the total wattage for each voltage level. Add the total wattage for each voltage level to arrive at the total combined power usage for the power subsystem. Table 9.
Appendix A: Regulatory and Compliance Information Appendix A: Regulatory and Compliance Information Product Regulatory Compliance Warning: To ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
Appendix A: Regulatory and Compliance Information Product EMC Compliance - Class A Compliance This server chassis has been tested and verified to comply with the following electromagnetic compatibility (EMC) ® regulations when installed in a compatible Intel host system. For information on compatible host system(s), refer to Intel's Server Builder Web site or contact your local Intel representative.
Appendix A: Regulatory and Compliance Information Product Regulatory Compliance Markings ® This Intel server chassis product bears the following regulatory marks. Table 10.
Appendix A: Regulatory and Compliance Information Regulatory Compliance RRL KCC Mark Region Marking Korea Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Appendix A: Regulatory and Compliance Information Europe (CE Declaration of Conformity) This product has been tested in accordance to, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. VCCI (Japan) English translation of the preceding notice: This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment.
Appendix A: Regulatory and Compliance Information • • • • Server board: you must use an Intel server board - UL recognized. Add-in boards: must have a printed wiring board flammability rating of minimum UL94V-1. Add-in boards containing external power connectors and/or lithium batteries must be UL recognized or UL listed. Any add-in board containing modem telecommunication circuitry must be UL listed.
Appendix B: Safety Information Appendix B: Safety Information English Server Safety Information ® ® This document applies to Intel server boards, Intel server chassis (pedestal and rackmount), and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and ® observe all warnings and precautions in this guide before installing or maintaining your Intel server product.
Appendix B: Safety Information Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than an ITE application, may require further evaluation.
Appendix B: Safety Information The power supply cord(s) is/are the main disconnect device to AC power. The socket outlet(s) must be near the equipment and readily accessible for disconnection. The power supply cord(s) must be plugged into socket-outlet(s) that is /are provided with a suitable earth ground.
Appendix B: Safety Information Other Hazards Battery Replacement Caution: There is the danger of explosion if the battery is incorrectly replaced. When replacing the battery, use only the battery recommended by the equipment manufacturer. Dispose of batteries according to local ordinances and regulations. Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery.
Appendix B: Safety Information Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel® Serverprodukt installieren oder warten.
Appendix B: Safety Information Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B. Medizin, Industrie, Alarmsysteme oder Prüfgeräte) kann u. U. weitere Tests erfordern. Standortauswahl Das System ist für den Betrieb innerhalb normaler Büroumgebungen geeignet.
Appendix B: Safety Information Vorsicht: Prüfen Sie zur Vermeidung von Stromschlag- oder Feuergefahr die mit dem Produkt zu verwendenden Netzkabel wie folgt: • • • • • • • Nehmen Sie keine Änderungen an einem Netzkabel vor, und benutzen sie es nicht, wenn es nicht genau in die geerdeten Netzsteckdosen paßt. Netzkabel müssen die folgenden Anforderungen erfüllen: Die Nennbelastbarkeit des Netzkabels muß mindestens so hoch sein wie die am Produkt angegebenen Nennstromaufnahme.
Appendix B: Safety Information Arbeitsplatz nicht zur Verfügung, erzielen Sie einen gewissen Schutz vor elektrostatischen Entladungen durch Tragen einer Antistatik-Manschette, die Sie während der Arbeit zur Erdung an einem beliebigen unlackierten Metallteil des Computergehäuses befestigen. Gehen Sei bei der Handhabung von Platinen immer mit größter Vorsicht vor. Sie können äußerst empfindlich gegenüber elektrostatischer Entladung sein. Halten Sie Platinen nur an den Kanten fest.
Appendix B: Safety Information Vous devez suivre les informations de ce guide et les instructions d’assemblage des manuels de serveur pour vérifier et maintenir la conformité avec les certifications et approbations de produit existantes. Utilisez uniquement les composants décrits et réglementés spécifiés dans ce guide.
Appendix B: Safety Information Domaines d’utilisation prévus Ce produit a été testé comme équipement informatique (ITE) et peut être installé dans des bureaux, des écoles, des salles informatiques et des endroits commerciaux similaires.
Appendix B: Safety Information Avertissements sur le cordon d’alimentation Si aucun cordon d’alimentation secteur n’a été fourni avec votre produit, vous devez vous en procurer un qui soit approuvé pour une utilisation dans votre pays.
Appendix B: Safety Information Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la terre. Décharges électrostatiques (ESD) Attention: Les décharges électrostatiques (ESD) peuvent endommager les lecteurs de disque dur, les cartes et d’autres pièces. Il est fortement conseillé d’effectuer l’ensemble des procédures décrites à un poste de travail protégé contre les ESD.
Appendix B: Safety Information Español Información de seguridad del servidor ® ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o mantener el producto de servidor de Intel®.
Appendix B: Safety Information Aplicaciones y usos previstos Este producto ha sido evaluado como equipo de tecnología informática (ITE) que puede instalarse en oficinas, escuelas, salas de equipos informáticos o lugares de ámbito comercial similares.
Appendix B: Safety Information Advertencias sobre el cable de alimentación Si no se ha proporcionado con el producto ningún cable de alimentación de CA, adquiera alguno cuyo uso esté aprobado en su país.
Appendix B: Safety Information El usuario es el responsable de la instalación de un dispositivo de desconexión de la alimentación principal para toda la unidad del bastidor. El acceso a este dispositivo de desconexión deberá ser de fácil acceso y deberán incluirse indicaciones que lo identifiquen como el control de alimentación eléctrica de toda la unidad, no sólo de los servidores.
Appendix B: Safety Information 简体中文 服务器安全信息 本文档适用于 Intel® 服务器主板、Intel® 服务器机箱(基座和机架固定件)和已安装的外设。为减少人身伤害、电击、火灾 以及设备毁坏的危险,请在安装或维护 Intel® 服务器产品之前阅读本文档并遵循本指南中的所有警告和预防措施。 如果本文档中的信息与特定产品的随附信息或 Web 站点信息之间存在不一致,请以产品文档为准。 服务器须由合格的技术人员进行集成和维护。 必须遵守本指南的规定和服务器手册的装配指导,以确保符合现有的产品认证和审 批。仅使用本指南中描述和规定的指定组件。使用其他产品/组件将使产品的 UL 认证和其他管理审批无效,并可能导致产品不符合销售地的产品法规。 安全警告与注意事项 为避免人身伤害与财产损失,安装本产品之前,请阅读以下所有安全指导和信息。 下面所列的安全符号可能在整个文档中使用并可能标注于产品和 / 或产品包装之上。 注意 注意 表示如果无视此项轻微人身伤害或财产损失的危险 警告 表示如果无视此严重人身伤害的危险 表示如果无视所示信息,即存在潜在的危险 表示如果不遵守安全指导
Appendix B: Safety Information 预期应用使用 根据评估,本产品为信息技术设备 (ITE),可安装在办公室、学校、计算机房和类似的商业场所。本产品对于非 ITE 应用的其他产品种类和环境(如医疗、工业、住宅、报警系统和测试设备)的适用 性尚有待进一步的评估。 场地选择 本系统专为在典型办公环境运行而设计。请选择符合以下条件的地点: 清洁、干燥,无气载微粒(而非一般的室内尘埃)。 通风良好,远离热源(包括直接日晒和散热器)。 远离振动源或物理震动。 与电气设备产生的强大电磁场隔离。 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 提供正确接地的墙壁插座。 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: 移举设备时遵守当地的职业健康与安全要求。 借助机械手段或其他合适的手段移举设备。 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系
Appendix B: Safety Information 若非所需的符合接地插座的确切类型,请勿尝试修改或使用交流电线 电源线须符合以下标准: 电源线的电气额定值须大于产品上标注的电流额定值。 电源线须拥有适合插座的安全接地插头或触点。 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: 关闭所有与本产品相连的外设。 按下电源按钮至关闭状态,关闭系统。 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 断开与系统相连的所有线缆和通信线路。 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维修事宜.
Appendix B: Safety Information 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有
Appendix B: Safety Information 注意事项 为避免幅射暴露和/或人身伤害: 请勿打开任何激光外设或激光设备的外壳 激光外设或激光设备为非用户维修设备 请与生产商联系维修事宜 Intel® Server Chassis SC5600 Service Guide 87
Appendix C: Installation/Assembly Safety Instructions Appendix C: Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply. The power button on the system does not turn off system AC power.
Appendix C: Installation/Assembly Safety Instructions A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts. Contact should be made with care. Consider wearing protective gloves. Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Dispose of used batteries according to manufacturer's instructions.
Appendix C: Installation/Assembly Safety Instructions SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus. 2. Schalten Sie das System mit dem Hauptschalter aus. 3. Ziehen Sie den Stromanschlußstecker Ihres Systems aus der Steckdose. 4.
Appendix C: Installation/Assembly Safety Instructions Français Le bloc d'alimentation de ce produit ne contient aucune pièce pouvant être réparée par l'utilisateur. Ce produit peut contenir plus d'un bloc d'alimentation. Veuillez contacter un technicien qualifié en cas de problème. Ne pas essayer d'utiliser ni modifier le câble d'alimentation CA fourni, s'il ne correspond pas exactement au type requis.
Appendix C: Installation/Assembly Safety Instructions Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une batterie du même type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. L'emplacement choisi doit être: 92 • "Propre et dépourvu de poussière en suspension (sauf la poussière normale).
Appendix C: Installation/Assembly Safety Instructions Español El usuario debe abstenerse de manipular los componentes de la fuente de alimentación de este producto, cuya reparación debe dejarse exclusivamente en manos de personal técnico especializado. Puede que este producto disponga de más de una fuente de alimentación No intente modificar ni usar el cable de alimentación de corriente alterna, si no corresponde exactamente con el tipo requerido.
Appendix C: Installation/Assembly Safety Instructions Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo. Para deshacerse de las pilas usadas, siga igualmente las instrucciones del fabricante. El sistema está diseñado para funcionar en un entorno de trabajo normal. Escoja un lugar: 94 • "Limpio y libre de partículas en suspensión (salvo el polvo normal).
Appendix C: Installation/Assembly Safety Instructions Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di questo prodotto. È possibile che il prodotto disponga di più fonti di alimentazione. Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde esattamente al tipo richiesto. Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c.a. separato.
Appendix C: Installation/Assembly Safety Instructions Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto. Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate dal produttore. Per disfarsi delle pile usate, seguire le istruzioni del produttore. Il sistema è progettato per funzionare in un ambiente di lavoro tipo. Scegliere una postazione che sia: 96 • "Pulita e libera da particelle in sospensione (a parte la normale polvere presente nell'ambiente).
Appendix D: Getting Help Appendix D: Getting Help World Wide Web http://support.intel.com/support/motherboards/server/chassis/SC5600/ If you encounter an issue with your server platform, please follow these steps to obtain support on your product. 1. Get connected to our support web page for 24x7 support when you need it to get the latest and most complete technical support information on all Intel Enterprise Server and Storage Platforms.
® Appendix E: Intel Server Issue Report Form Appendix E: Intel® Server Issue Report Form Issue Report Form (Rev 3.5) NOTE: Filling out this form completely is required for any escalation. Note: An online/automatic submission version of this form is available at http://support.intel.com/support/motherboards/server/chassis/sc5600/. For the fastest service, please submit your form via the Internet.
® Appendix E: Intel Server Issue Report Form Has the latest FRU/SDR been tried? (Yes/No): Has the latest HSC been tried? (Yes/No): Processor information: Type Speed sSpec Thermal Solution Processor 1 Processor 2 Processor 3 Processor 4 Thermal solution (Heat sink) examples: (1U, Passive w/air ducting, Active w/fan, and so on) Memory: Manufacturer Part Number DRAM Part Number On Intel tested list? Add-in adapters (Example: NICs, Management Adapters, Serial Expansion Cards, PCIExpress* Adapters, R
® Appendix E: Intel Server Issue Report Form Other third-party hardware (Example: Example: KVM, Chassis, and so on): Description/Use Manufacturer Model Firmware Storage Devices (Example: SCSI, SATA, SAS, USB, Tape, and so on): Manufacturer Model Type Size Firmware In Hot Swap Bay? Operating System Information (Example: Red Hat* Enterprise Linux, Microsoft Windows Server 2003*, Service pack 1, OEM CD): Manufacturer: Version: Language version (English, Arabic, Chinese (Simplified)): Service Pack L
® Appendix E: Intel Server Issue Report Form BBU part number: Detailed description of issue: Troubleshooting tried: Steps to replicate the issue: Intel® Server Chassis SC5600 Service Guide 101
® Appendix E: Intel Server Issue Report Form Issue impact statements: Do you have any potential Intel system, or component purchases that this issue is holding up? If yes, please provide a brief description below. Do you have systems already purchased that are not being delivered to your customers because of this issue? If yes, please provide a brief description below.
Appendix F: Warranty Appendix F: Warranty Limited Warranty for Intel® Chassis Subassembly Products ® Intel warrants that the Products (defined herein as the Intel chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and installed, will be free from defects in material and workmanship and will substantially conform to Intel's publicly available specifications for a period of three (3) years after the date t
Appendix F: Warranty Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.